Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In the present study, the partial-discharge activity under nonstandard voltage formed by ac, harmonic, and dc voltages was studied. It is identified that the negative dc voltage superposed with ac and high frequency harmonic enhances the discharge activity in the medium and if the negative dc voltage is superposed with ac and low frequency harmonic, it can mitigate the discharge activity. The signal of the partial discharges in oil-paper insulated systems under the composite voltage formed by dc superposed with ac and harmonic voltages, has a dominant frequency content at around 20 MHz.
PL
Analizowano wyładowania niezupełne przy niestandardowych napięciach złożonych z napięć AC i DC. Stwierdzono, że obecność napięcia stałego zwiększa prawdopodobieństwo wyładowań. Zbadano wyładowania niezupełne w izolacji papierowo-olejowej.
2
Content available remote Partial discharge of oil-paper insulation under DC voltage superimposed AC voltage
PL
Izolacja transformatorów w przekształtnikach jest narażona na napięcia AC i DC. Przeprowadzono analizę wyładowań niezupełnych w izolacji z papieru olejowego w systemach napięcia stałego z obecnością składowej przemiennej. Zarejestrowano wyładowania przy użyciu oscyloskopu o paśmie 5 GHz. Badania przeprowadzona dla napięcia DC, AC oraz DC plus AC. Impulsy prądu wyładowań mają inną amplitudę, czas narastania i energię w zależności od rodzaju napięcia. Istotną sprawą jest napięcia. Zaproponowano efektywna metodą monitorowania jakości izolacji transformatorów w przekształtnikach.
EN
The insulation of converter transformer is stressed by AC and DC voltages. To investigate partial discharge (PD) characteristic of oilpaper insulation, this paper designed a power source system of DC superimposed AC voltage. The testing sample is an air gap model in the middle of an insulation cardboard. A broadband current transformer is used to measure PD current recorded by an oscilloscope with a bandwidth of 5 GHz. Experiments are performed under AC,DC only, and DC superimposed AC voltages with the sample immersed in transformer oil using electrode configurations that is parallel plate. The single PD pulses are anglicized by ORIGIN software. It is realized that the impulse current signals generated due to partial discharges under AC and DC voltages are different with amplitude, rise time, counts, duration and energy content PD pulse under AC voltage is of long duration pulse compared to that generated under DC voltage, and the PD pulse under DC superimposed AC voltage is stochastic. The key point is the moment (phase position) PD occurring moves to the zero point of the applied voltage than the case only under ac voltage. These will contribute to the development of effective PD monitoring systems for oil-insulated converter transformer.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.