Purpose: The aim of this publication is to present the most important aspects of using smoke and carbon monoxide detectors intended for households or similar residential facilities as well as to indicate the advantages and disadvantages of the adopted system solutions that affect the number of detectors installed in this kind of buildings. The article aims to present the issues related to the Integrated Qualifications System (ZSK), i.e. newly developed market qualification, dedicated to installers and maintenance technicians of smoke and carbon monoxide detectors. Introduction: Smoke and carbon monoxide detectors for early detection of existing threats such as fires or escaping carbon monoxide are an important element of fire protection, dedicated primarily to owners of residential buildings. In many countries in the EU it is obligatory to install detectors in homes, whereas at the moment in Poland the only aspect regulated legally is the obligation of the manufacturer of these products to obtain a certificate. Since 2016, the ZSK has been operating in Poland, in which in 2019 the qualifications of installers/maintenance technicians of smoke and carbon monoxide detectors were distinguished. As a result, a person with a market qualification certificate is prepared for independent installation and maintenance of fire safety monitoring devices Methodology: As part of the research process, theoretical research was used, such as: analysis of literature and legal documents, synthesis, generalization, inference, comparison and analogy. As part of the research, documents from such countries as Poland, Great Britain (mainly England), Germany and France were analysed. The selection of individual countries was guided by the level of development of these systems in a given country and the availability of source documents Conclusions: The presented analysis of the requirements for the installation of the smoke and carbon monoxide detectors shows how different the approach is regarding the use of this type of devices. Depending on experiences and the administrative structure of a given country, a variety of regulations, whether legal or normative, can be discerned in the use of smoke and carbon monoxide detectors. ZSK is a well-described system of formal organization and classification of competences and offers the public services at the highest possible quality level. It is also a partial solution to the problem of installing detectors. However, it is necessary to regulate this issue from the legal level, as it was the case in other EU countries, where the installation of detectors in homes is obligatory. Such action will contribute to reducing the victims of fires or inhalation of toxic gases (carbon monoxide).
PL
Cel: Celem niniejszej publikacji jest przedstawienie najważniejszych aspektów stosowania czujek dymu i czujek tlenku węgla w prywatnych obiektach mieszkalnych, a także wskazanie zalet oraz wad przyjętych rozwiązań systemowych, które mają wpływ na liczbę detektorów montowanych w tego typu obiektach. Artykuł przedstawia również zagadnienia związane z Zintegrowanym Systemem Kwalifikacji (ZSK), tj. opracowanej kwalifikacji rynkowej, dedykowanej monterom i konserwatorom czujek dymu i czujek tlenku węgla. Wprowadzenie: Czujki dymu i czujki tlenku węgla to ważny element zabezpieczeń obiektów mieszkalnych. Dedykowane są one wszystkim właścicielom tych obiektów. W wielu krajach UE obligatoryjne jest montowanie czujek w domach, natomiast obecnie w Polsce wymagane jest jedynie ich certyfikowanie przez producenta. Od 2016 roku w Polsce funkcjonuje ZSK, w którym w roku 2019 wyodrębniono kwalifikacje dla monterów/konserwatorów czujek dymu i czujek tlenku węgla. Dzięki temu osoba posiadająca certyfikat kwalifikacji rynkowej jest przygotowana do samodzielnego montażu i konserwacji urządzeń monitorujących bezpieczeństwo pożarowe. Metodologia: W ramach procesu badawczego wykorzystano badania teoretyczne, takie jak: analiza literatury i dokumentów prawnych, synteza, uogólnianie, wnioskowanie, porównanie oraz analogia. Podczas badań dokonano analizy dokumentów z Polski, Wielkiej Brytanii (głównie Anglii), Niemiec i Francji. Przy ich doborze kierowano się poziomem rozwoju tych systemów w danym kraju oraz dostępnością dokumentów źródłowych. Wnioski: Przedstawiona analiza wymagań w zakresie obowiązku instalacji czujek dymu i czujek tlenku węgla pokazuje, jak różne jest podejście do ich stosowania w Polsce i w wybranych państwach europejskich. W zależności od doświadczeń oraz struktury administracyjnej danego kraju można dostrzec różnorodność przepisów prawnych czy normatywnych. ZSK jest opisanym systemem formalnego uporządkowania i klasyfikacji kompetencji i oferuje społeczeństwu usługi na możliwie najwyższym poziomie jakościowym. Niezbędne jest prawne uregulowanie tej kwestii, tak jak zostało to zrobione w innych krajach UE, gdzie instalacja czujek w domach jest obowiązkowa. Takie działanie przyczyni się do zredukowania ofiar pożarów lub zaczadzeń.
Aim: The aim of this publication is to present the most important aspects concerning the conditions for evacuation of people with various types of disabilities – from mobility problems, to reduced perception in the event of a threat, and to indicate the most important challenges both in terms of legal regulations, as well as organizational and technological conditions for ensuring effective evacuation of disabled people. Introduction: People with disabilities are a group that requires special consideration when planning evacuation from public utility facilities, because many of these people – depending on the type and degree of their dysfunction – will not be able to evacuate from the danger zone on their own. The inspection carried out in 2019 by the Delegation of the Supreme Audit Office in Poznań confirmed the need to adapt the applicable legal regulations in this regard (in practice, fire safety instructions, evacuation plans, staff training and equipping facilities with adequate equipment supporting the evacuation of people with disabilities) [1]. In addition to legal and technological aspects, a very important factor in the effective evacuation of disabled people are organizational solutions adopted in a given facility, which should take into account the individual specificity (cubature) and functions of a given facility. Methodology: As part of the research process, theoretical research was used, such as: analysis of literature and legal documents, synthesis, generalization, inference, comparison and analogy. During the research, national and foreign sources (from the United States and Great Britain) were analyzed. The selection of individual countries was guided by the level of development of the solutions adopted in these countries dedicated to supporting the evacuation of disabled people in a situation of threat to their life or health, as well as the availability of data sources. Conclusions: The presented analysis of the conditions for the evacuation of people with disabilities from public utility buildings shows the challenges that both the legislator and managers of facilities in the country face in this area, as well as the emergency services. The latter – similarly to people with disabilities – are the systemic beneficiaries of the desired changes in the area of law and tactics of rescue operations, from the moment of alerting about an event in the facility where there are people who are unable to evacuate themselves. Introducing good practices, verified in other countries, into common application, should significantly improve rescue operations. The expected effect will be to shorten the time of providing help to all people unable to evacuate themselves in an emergency – regardless of their number, as well as the type and specificity of the public facility in which the life or health threatening situation occurred.
PL
Cel: Celem niniejszej publikacji jest przedstawienie najważniejszych aspektów dotyczących warunków ewakuacji osób z różnymi rodzajami niepełnosprawności – począwszy od problemów z poruszaniem się, na ograniczeniu percepcji w sytuacji wystąpienia zagrożenia skończywszy – oraz wskazanie najważniejszych wyzwań zarówno na płaszczyźnie regulacji prawnych, jak i warunków organizacyjnych oraz technologicznych dla zapewnienia skutecznej ewakuacji osób niepełnosprawnych. Wprowadzenie: Osoby niepełnosprawne to grupa wymagająca szczególnego uwzględnienia w przypadku planowania ewakuacji z obiektów użyteczności publicznej, ponieważ wiele z tych osób – w zależności od rodzaju i stopnia posiadanej dysfunkcji – nie będzie w stanie samodzielnie ewakuować się ze strefy zagrożenia. Przeprowadzona w 2019 roku kontrola Delegatury Najwyższej Izby Kontroli w Poznaniu potwierdziła konieczność dostosowania obowiązujących regulacji prawnych w tym zakresie (w praktyce instrukcji bezpieczeństwa pożarowego, planów ewakuacji, przeszkolenia personelu oraz wyposażenia obiektów w adekwatny sprzęt wspomagający ewakuację osób z niepełnosprawnością) [1]. Poza aspektami prawnymi i technologicznymi, bardzo istotny czynnik skutecznej ewakuacji osób niepełnosprawnych stanowią przyjęte w danym obiekcie rozwiązania organizacyjne, które powinny uwzględniać indywidualną specyfikę (kubatura) oraz funkcje danego obiektu. Metodologia: W ramach procesu badawczego wykorzystano badania teoretyczne, takie jak: analiza literatury i dokumentów prawnych, synteza, uogólnianie, wnioskowanie, porównanie oraz analogia. Podczas badań dokonano analizy źródeł krajowych oraz zagranicznych (ze Stanów Zjednoczonych Ameryki i Wielkiej Brytanii). Przy doborze poszczególnych państw kierowano się poziomem rozwoju przyjętych w tych państwach rozwiązań dedykowanych wsparciu ewakuacji osób niepełnosprawnych w sytuacji zagrożenia dla ich życia lub zdrowia, a także dostępnością źródeł danych. Wnioski: Zaprezentowana analiza warunków ewakuacji osób z niepełnosprawnością z obiektów użyteczności publicznej pokazuje wyzwania, jakie w tym obszarze stoją zarówno przed legislatorem, jak i zarządcami obiektów w kraju, a także przed służbami ratowniczymi. Te ostatnie – podobnie jak osoby niepełnosprawne – są systemowym beneficjentem pożądanych zmian w obszarze przepisów prawa oraz taktyki prowadzonych działań ratowniczych, już od momentu alarmowania o zdarzeniu w obiekcie, w którym przebywają osoby niezdolne do samodzielnej ewakuacji. Wprowadzenie do powszechnego zastosowania dobrych praktyk, sprawdzonych w innych państwach, powinno w wyraźny sposób usprawnić działania ratownicze. Spodziewanym efektem będzie skrócenie czasu dotarcia z pomocą do wszystkich osób niezdolnych do samodzielnej ewakuacji w sytuacji zagrożenia – bez względu zarówno na ich liczbę, jak i na rodzaj i specyfikę obiektu użyteczności publicznej, w którym doszło do sytuacji zagrażającej życiu lub zdrowiu.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.