Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Microelectrode arrays based (bio)analytical systems
EN
Two types of systems: microelectrode array based analytical system for voltammetric monitoring of trace metals in natural waters and interdigitated electrodes system for electrochemiluminescence based analysis of codeine in pharmaceutical samples and for detection of ruthenium (II) complex label is described in the paper. The thin-film technology was used for microfabrication of an array of 100 interconnected Ir microdisc electrodes on Si/ShN4 substrate. The electrochemiluminescence system combines electrodes, a flowthrough cell and a photodetector on the same silicon chip.
PL
W artykule opisano dwa rodzaje systemów: system analityczny zawierający matrycę mikroelektrod do woltamperometrycznego monitorowania śladowych metali w wodach naturalnych oraz układ zawierający międzypalczaste elektrody do elektrochemiluminescencyjnej analizy zawartości kodeiny w próbkach farmaceutycznych i detekcji znaczników zawierających kompleksy rutenu (II). Zastosowano technologię cienkowarstwową do nanoszenia na podłoże Si/Si3N4, matrycy, zawierającej 100 mikrodyskowych elektrod. Układ elektrochemiluminescencyjny składał się z elektrod, celki przepływowej i fotodetektorów, wykonanych na jednej płytce półprzewodnikowej.
EN
The potentiality of species-selective supported liquid membrane device (SLM) for trace metal measurements under natural water conditions has been investigated. Cu(II) speciation studies with various synthetic hydrophilic ligands (sulphosalicylic acid, hydroxyquinoline sulphonic acid and oxalic acid) and naturalligands such as fulvic acids were done using 1, 10 -didecyl-l, 10-diazacrown ether -Iauric acid/phenyl hexane-toluene on flat and hollow fibre supported liquid membranes. The salient features of the results ob-tained are that only free metal ions are transported across this SLM and the negatively charged complexes and neutral complex do not pass through within the time scale of the measurement. Low free metal concentrations can be measured and most importantly the experimentally observed values of degree of complexation are in good agreement with the theoretically calculated ones, the correlation coefficient being ł. 1.01+ 0.02. These findings suggest that SLM can be used as an alternative method for speciation studies in natural waters.
PL
Badano potencjalne możliwości selektywnej ciekłej membrany do oznaczania i specjacji śladów metali w wodach naturalnych, Specjację Cu(II) badano używając takich ligandów jak' kwas sulfosalicylowy, kwas sulfonohydroxychionolinowy, kwas szczawiowy i kwas fulwinowy, oraz wspartą na włóknach ciekłą membranę l, 10-didecyl-l, l0-diazakorona eter- kwas laurowy/tenylohexau -toluen Stwierdzono, że wodne jony metali mogły przejść przez membranę, a ujemnie naładowane jony i kompleksy obojętne nie, Nowy typ membrany umożliwia zatem pomiar stężenia wodnych jonów metali i stopień skompleksowania.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.