In refrigeration nowadays, there is a dynamic return to the use of natural refrigerants such as hydrocarbons. These substances do not contain fluorine and chlorine, which contribute to the enlargement of the ozone hole and the greenhouse effect. Hydrocarbons, however, are substances from the A3 safety group (flammable) and are currently mainly used in low-capacity devices. The most commonly used refrigerant in this group is R600a (isobutene). In refrigeration compressors, a situation may occur where the amount of oil in friction nodes is insufficient. In this case, there may be poor lubrication conditions. A situation may also arise in which the lubricant in the friction areas runs out, and the lubrication of the friction nodes will be performed exclusively by the refrigerant. The article presents a concept of a test method allowing an assessment of lubricity properties of oils for refrigeration compressors in the mixture with a refrigerant in the conditions of poor lubrication and in the absence of lubrication with a lubricant. It also contains the results of wear tests that enable an evaluation of the lubricity properties of oil-refrigerant mixtures in the conditions of poor lubrication. The results were obtained for ecological, and recommended for a wider future use, R600a refrigerant with mineral oils. It is also indicated that it is possible to compare various refrigerants in the absence of lubricant and to replicate lubricity properties of oil-refrigerant mixtures in the conditions of poor lubrication and to apply the proposed method for the evaluation of different lubricants in use with a selected refrigerant.
PL
Obecnie w chłodnictwie następuje dynamiczny powrót do stosowania naturalnych czynników chłodniczych takich jak węglowodory. Są to substancje niezawierające fluoru i chloru, które przyczyniają się do powiększania dziury ozonowej oraz efektu cieplarnianego. Węglowodory to jednak substancje z grupy bezpieczeństwa A3 (palne) i są obecnie głównie wykorzystywane w urządzeniach o małej wydajności. Najpowszechniej stosowanym czynnikiem chłodniczym w tej grupie urządzeń jest R600a (izobutan). W sprężarkach chłodniczych może wystąpić sytuacja, w której ilość oleju w węzłach tarcia jest niewystarczająca. Wówczas mogą wystąpić skąpe warunki smarowania. Może również zaistnieć sytuacja, w której środka smarnego zabraknie w obszarach tarcia, a smarowanie węzłów będzie realizowane tylko przez czynnik chłodniczy. W artykule przedstawiono koncepcję metody badań pozwalających na ocenę właściwości smarnych olejów do sprężarek chłodniczych w mieszaninie z czynnikiem chłodniczym w warunkach skąpego smarowania oraz braku smarowania środkiem smarnym. Umieszczono również wyniki badań zużyciowych pozwalających na ocenę właściwości smarnych mieszanin olej – czynnik chłodniczy w warunkach skąpego smarowania uzyskanych dla ekologicznego i wskazanego do szerszego stosowania w przyszłości czynnika chłodniczego R600a z olejami mineralnymi. Wskazano również na możliwości porównania między sobą różnych czynników chłodniczych podczas braku środka smarnego oraz odwzorowania właściwości smarnych mieszanin olej/czynnik chłodniczy w warunkach skąpego smarowania i wykorzystania proponowanej metody do oceny rożnych środków smarnych do zastosowania z wybranym czynnikiem chłodniczym.
EN
In the case of mining machines, tribocorrosion damage is often observed. This type of consumption is caused by the joint action of mining environment factors such as abrasive and water. The search for methods to counteract tribocorrosion is of great practical importance, but it must be combined with the knowledge of methods of forecasting the value of wear. This paper presents a model of prediction of tribocorrosive wear adapted to corrodible materials – ADI containing Ni and Cu, with the strength class of 800 MPa – and results of a two-stage study on the tribocorrosive wear. Presented results indicate a distinct effect of synergy between friction and corrosion in the total wear of ADI. The tribocorrosion tests confimed the adequacy of the model developed for the ADI.
EN
The paper presents results of a two-stage study on the tribocorrosive wear of ADI alloy cast iron containing Ni and Cu. In the first stage of the wear tests with use test rig type pin-on-plate, there were determined the parameters of the process of tribocorrosion of the ADI cast iron in 3.5% NaCl solution. In the second stage, the tests were carried out on a test rig simulating real operating conditions of chain wheels used in armoured face conveyors. The purpose of this study was to demonstrate the impact of the combined action of corrosive agents (water and NaCl) and quartz abrasive on the wear of the wheels tested. As part of the test, the abrasive wear in the presence of the abrasive material alone and in the presence of a mixture of the abrasive material, water and NaCl was determined. The microstructure and the hardness of the surface layer as a function of the distance from the surface were also determined. During the study it has been found that regardless of the type of test there is a synergy between the effects of corrosion and friction which led to an increase of the resulting wear by 30%.
EN
There has currently been a dynamic return to applying natural refrigerants such as hydrocarbons. They are substances containing neither fluorine nor chlorine, which contribute to the enlargement of the ozone hole and the greenhouse effect. However, hydrocarbons are the substances from the A3 safety group (flammable) and, at present, are mainly used in appliances of low efficiency. The most widely used refrigerant in this category of appliances is R600a (isobutene). While repairing refrigeration appliances, there is often the need to remove the refrigerant and compressor oil from the system. Any impurities in the system are also removed. Should incorrect removal of the used oil from the installation occur, there is the risk that a certain amount of the oil and flushing fluid shall remain in the refrigeration system. The article presents an evaluation of the effect of a flushing fluid for refrigeration systems on lubricity properties of compressor oils. The article also describes the research on the use of R600a, a mineral oil of VG ISO 32 and commercially available FF1 flushing fluid, for refrigeration systems. The evaluation was made on the basis of the sample wear volume in the block-on-ring node under the conditions similar to compressor exploitation following a longer shut-off period. Three different lubricants were compared: a mixture of mineral oil with FF1 flushing fluid for refrigeration systems in the amount 20% by volume, a mixture of mineral oil with FF1 flushing fluid for refrigeration systems in the amount 50% by volume, and a mixture of mineral oil with FF1 flushing fluid for refrigeration systems in the amount 50% by volume with R600a.
PL
Obecnie w chłodnictwie następuje dynamiczny powrót do stosowania naturalnych czynników chłodniczych takich jak węglowodory. Są to substancje niezawierające fluoru i chloru, które przyczyniają się do powiększania dziury ozonowej oraz efektu cieplarnianego. Węglowodory to jednak substancje z grupy bezpieczeństwa A3 (palne) i są obecnie głównie wykorzystywane w urządzeniach o małej wydajności. Najpowszechniej stosowanym czynnikiem chłodniczym w tej grupie urządzeń jest R600a (izobutan). Przy czynnościach naprawczych urządzeń chłodniczych istnieje często potrzeba usunięcia z układu czynnika chłodniczego i oleju sprężarkowego. Usuwa się również wszelakie zanieczyszczenia znajdujące się w instalacji. W tym celu często używa się płynów do płukania instalacji chłodniczej. Przy nieprawidłowym wykonaniu operacji usuwania z instalacji zużytego oleju istnieje niebezpieczeństwo, że pewna ilość tego oleju i środka czyszczącego pozostanie w instalacji chłodniczej. W artykule przedstawiono ocenę wpływu środka do czyszczenia układów chłodniczych na właściwości smarowe olejów sprężarkowych. Przedstawiono badania z wykorzystaniem czynnika chłodniczego R600a, oleju mineralnego z klasy lepkości VG ISO 32 oraz dostępnego w sprzedaży środka do czyszczenia układów chłodniczych FF1. Oceny dokonano na podstawie zużycia objętościowego próbki w węźle rolka–klocek w warunkach zbliżonych do eksploatacji sprężarki po długim okresie wyłączenia. Porównano trzy różne substancje smarne: mieszaninę oleju mineralnego ze środkiem do czyszczenia układów chłodniczych FF1 w ilości 20% objętości, mieszaninę oleju mineralnego ze środkiem do czyszczenia układów chłodniczych FF1 w ilości 50% objętości oraz mieszaninę oleju mineralnego ze środkiem do czyszczenia układów chłodniczych FF1 w ilości 50% objętości wraz z czynnikiem chłodniczym R600a.
EN
The problems with lubrication in refrigeration compressors are usually caused by the presence of the oil-refrigerant mixture in friction nodes. One cannot assess lubricity properties of oil under its operating conditions based on test results that characterize oil exclusively. For this purpose, it is necessary to test the lubricity properties of the oil-refrigerant mixture. The article presents the concept of an assessment method for the lubricity properties of oils for refrigeration compressors in a mixture with a refrigerant. The essential elements of the proposed method are the procedure for selecting wear test duration time (τt) and the oil-refrigerant mixture formation time (τm).
PL
W sprężarkach chłodniczych problemy ze smarowaniem zazwyczaj spowodowane są obecnością mieszaniny olej–czynnik chłodniczy w węzłach tarcia. Nie można skutecznie ocenić właściwości smarnych oleju do sprężarek chłodniczych w warunkach jego eksploatacji na podstawie wyników badań charakteryzujących tylko olej. W tym celu konieczne jest wykonywanie badań mieszaniny olej–czynnik chłodniczy. W artykule przedstawiono koncepcję metody badań pozwalających na ocenę właściwości smarnych olejów do sprężarek chłodniczych w mieszaninie z czynnikiem chłodniczym. Istotne elementy proponowanej metody to procedura wyznaczania czasu trwania testu zużyciowego (τt) oraz czasu wytwarzania mieszaniny (τm).
EN
Current legal regulations concerning ozone-depleting substances and greenhouse gases result in a dynamic return to the use of natural refrigerants such as hydrocarbons. However, they are gases included in the A3 (combustible) security group, and that is why they are now mainly used in devices with low performance (mainly in household refrigerators). The most widely used hydrocarbon as a refrigerant in this group of devices is R600a (isobutene). The article presents a comparative assessment of the lubricity properties of oil-refrigerant mixtures of three mineral oils with R600a. The assessment was based on a sample wear volume of the block-on-ring node under the conditions approximating the operation of the compressor after an extensive standstill period. The oil/refrigerant mixture was obtained as a result of an appropriately extended mutual contact of both substances in a closed chamber.
PL
Aktualne regulacje prawne dotyczące substancji zubożających warstwę ozonową oraz gazów cieplarnianych powodują dynamiczny powrót do stosowania naturalnych czynników chłodniczych, takich jak węglowodory. Są to jednak gazy zaliczane do grupy bezpieczeństwa A3 (palne), przez co znajdują obecnie głównie zastosowanie w urządzeniach o małej wydajności (głównie w chłodziarkach domowych). Najpowszechniej stosowanym czynnikiem chłodniczym w tej grupie urządzeń jest R600a (izobutan). W artykule przedstawiono ocenę porównawczą właściwości smarnych mieszanin trzech olejów mineralnych z czynnikiem chłodniczym R600a. Oceny dokonano na podstawie zużycia objętościowego próbki w węźle rolka – klocek w warunkach zbliżonych do eksploatacji sprężarki po długim okresie wyłączenia. Mieszaninę olej – czynnik chłodniczy uzyskano w wyniku odpowiednio długiego wzajemnego kontaktu obu substancji w zamkniętej komorze badawczej.
PL
W węzłach tarcia sprężarek chłodniczych zawsze znajduje się mieszanina oleju i czynnika chłodniczego. W artykule przedstawiono wyniki badań modelowego węzła ślizgowego smarowanego olejami i mieszaninami różnych olejów poliestrowych z tej samej klasie lepkości ISO VG 32 z czynnikiem chłodniczym R134a. Stwierdzono znaczące różnice zużycia zarówno po testach samych olejów, jak i mieszanin z R134a. Przeprowadzono badania spektralne badanych olejów. Potwierdzono, że są to oleje poliestrowe zawierające dodatki uszlachetniające (ditiofosforan). Dodatkowo w oleju POE1 wykryto dodatek z ugrupowaniami siarkowymi (najprawdopodobniej dyspergator sulfonianowy). Stwierdzono, że obecność tego dodatku w oleju POE1 jest przyczyną mniejszego zużycia skojarzenia modelowego smarowanego tym olejem, jak również mieszaniną POE1/R134a. Badania profilometryczne zużytych powierzchni potwierdziły skuteczność tego dodatku.
EN
Friction pairs of refrigeration compressors are always lubricated by an oil/refrigerant mixture. This paper presents the results of wear amounts after tribological tests of different polyester oils from the same viscosity class ISO VG 32 and polyester oils/refrigerant R134a mixtures. Results showed a significant difference in wear after test with just oils as well as with mixtures with R134a. Spectral studies of tested oils were performed. It was confirmed that these are all polyester oils containing additives (dithiophosphate). In addition, in POE1 oil, the additive with sulfur groups (most likely a dispersant sulfonate) was detected. It has been found that the presence of the additive in the oil POE1 causes less wear in the friction node lubricated with both oil and a mixture POE1/R134a. The profilometric study of the used surface confirmed the effectiveness of the detected additive.
PL
Dokonano mikrostrukturalnej oraz fizykochemicznej charakterystyki aerożeli zastosowanych do wytwarzania pianek poliuretanowych. Określono najistotniejsze parametry dyspersyjne napełniaczy oraz ich charakter hydrofilowo-hydrofobowy. Kompozyty przebadano pod kątem wytrzymałości na ściskanie i rozciąganie. Bardzo istotnych informacji dostarczyły badania termoizolacyjnych właściwości otrzymanych kompozytów przeprowadzone metodą ścianki pomocniczej. Stwierdzono, że pianka z dodatkiem napełniacza PEX 40 jest najbardziej odpowiednia (w przyszłych badaniach aplikacyjnych) jako materiał o względnie dobrych właściwościach termoizolacyjnych.
EN
Eight com. aerogels were used as fillers for polyurethane foams tested for their compression and tensile strength. The addn. of selected aerogel filler resulted in enhancing of the thermal insulating properties of the foam.
PL
Obecnie następuje powrót do ekologicznych czynników chłodniczych. Jest to w dużej mierze związane z obowiązującymi przepisami dotyczącymi stosowania substancji zubożającej warstwę ozonową. Celem pracy było przeprowadzenie badań dotyczących wpływu zastąpienia czynnika R134a ekologicznym propanem w mieszaninie olej–czynnik chłodniczy na powierzchnie ślizgowe sprężarek tłokowych. Badania wykonano w mieszaninach oleju mineralnego z czynnikami chłodniczymi R134a i R290 oraz w mieszaninach oleju syntetycznego poliestrowego z czynnikami R134a i R290. Testy przeprowadzono za pomocą maszyny tarciowej z wykorzystaniem węzła typu block-on-ring, który znajduje się w komorze symulującej wnętrze sprężarki chłodniczej. Uzyskane wyniki badań potwierdzają możliwość wykorzystania propanu jako zamiennika R134a.
EN
Due to valid regulations concerning the application of substances weakening the ozone layer, at present, there is reversion to ecological refrigerants. The purpose of the work was testing the influence of substituting the refrigerant R134a with ecological propane in the mixture of oil and refrigerant on sliding surfaces of piston compressors. The tests were carried out in mixtures of mineral oil with refrigerants R134a and R290 and in mixtures of synthetic polyester oil with refrigerants R134a and R290. The tests were performed with the use of a friction machine using a pair type block-on-ring, which was situated in the chamber simulating the inside of the refrigerating compressor. The results obtained from the performed tests confirm the possibility of using propane instead of R134a.
10
Content available Uogólniony model zużywania tribokorozyjnego
PL
W artykule podjęto próbę aproksymowania wyników badań zużywania tribokorozyjnego stali odpornych na korozję AISI 304 i AISI 420 w 0,5 M roztworze H2SO4. Testy wykonano na specjalistycznym stanowisku z węzłem modelowym typu pin-on-plate. W poszczególnych seriach różnicowano nacisk w strefie styku (p) i częstotliwość ruchu przeciwpróbki (f). Do aproksymacji wykorzystano model zużywania w postaci ogólnej: Ih= Kpx (Ih - liniowa intensywność zużywania, K., x - stałe materiałowe). Uzyskano zadowalające rezultaty aproksymacji (współczynnik korelacji powyżej 0,85). Jednocześnie stwierdzono, że skuteczność zastosowanego modelu maleje ze wzrostem tempa oddziaływań korozyjnych.
EN
The article attempts to approximate the results of studies of tribocorrosion wear of stainless steel AISI 304 and AISI 420 in 0.5 M H2SO4 solution. The tests were performed in a specialized position of the node model pin-on-plate. In particular, a series of differentiated pressures in the contact zone (p) and the frequency of counter-specimen movement (f) were used. The approximation model was used for wear in the general form: Ih = Kpx (Ih -linear wear intensity, K, x - solid materials). Approximation obtained satisfactory results (correlation coefficient of 0.85 above). At the same time, it was found that the effectiveness of the applied model decreases with an increase in the rate of corrosion effects.
PL
W układach chłodniczych jedynym elementem narażonym na zużywanie mechaniczne węzłów tarcia jest sprężarka. Główne przyczyny uszkodzeń mechanicznych sprężarek chłodniczych związane są z obecnością czynnika chłodniczego w misce olejowej i w oleju smarowym, gromadzącego się podczas dłuższych przerw w pracy. W fazie rozruchu sprężarki następuje gwałtowne odparowanie pewnej ilości czynnika chłodniczego zgromadzonej w misce olejowej sprężarki oraz w oleju, co prowadzi do jego spienienia. Jest to zjawisko niepożądane, lecz powszechne w eksploatowaniu urządzeń chłodniczych. W artykule przedstawiono stanowisko do badania zużycia podczas pienienia oleju w sprężarkach chłodniczych. Przedstawiono również wyniki badań potwierdzające negatywny wpływ zjawiska pienienia oleju smarowego zanieczyszczonego czynnikiem chłodniczym na trwałość elementów węzłów tarcia sprężarek chłodniczych.
EN
The only element of refrigeration systems exposed to mechanical wear of friction is the refrigeration compressor. The main reasons for refrigeration compressor mechanical failures are related to the presence of refrigerant in the lubricating oil accumulating during long cessation periods and the rapid evaporation of a certain amount of refrigerant accumulated in the crankcase of the compressor during the start-up stage. It leads to foaming of the oil. This is an undesirable but common phenomenon in the exploitation of refrigeration compressors. The article presents the study of wear during the foaming of oil in refrigeration compressors. It also presents the results of studies demonstrating the negative effect of the foaming of lubricating oil contaminated with refrigerant on the durability of friction joints in refrigeration compressors.
EN
Lubricating medium in friction pairs of refrigerating compressors is always a mixture of oil and refrigerant. Therefore, the problem of choosing lubricating oil for co-operation with refrigerant applied in the device is essential for the durability of refrigerating compressors. Valid regulations concerning refrigerants constrain their progressive exchange to the ecological ones. One of the perspective refrigerants considered as a substitute of the generally withdrawn refrigerant R22 is propane R290. Each substance used as refrigerant behaves in a different way in contact with oil in the operation conditions of refrigerating compressors. This paper discusses the attempt of selecting wear tests parameters of refrigerating compressors’ friction pairs lubricated with a mixture of mineral oil and the ecological refrigerant propane R290.
PL
W węzłach tarcia sprężarek chłodniczych medium smarowe zawsze stanowi mieszanina oleju z czynnikiem chłodniczym. Problem doboru oleju smarowego do współpracy z zastosowanym w urządzeniu czynnikiem chłodniczym jest więc kluczowym w kontekście trwałości sprężarek chłodniczych. Obowiązujące regulacje prawne dotyczące czynników chłodniczych wymuszają ich stopniową wymianę na substancje ekologiczne. Jednym z perspektywicznych czynników chłodniczych rozpatrywanym jako zamiennik powszechnie wycofanego czynnika chłodniczego R22 jest propan R290. Każda substancja wykorzystywana jako czynnik chłodniczy zachowuje się inaczej w kontakcie z olejem w warunkach pracy sprężarek chłodniczych. W artykule podjęto próbę doboru parametrów badań zużyciowych węzłów tarcia sprężarek chłodniczych smarowanych mieszaniną oleju mineralnego i ekologicznego czynnika chłodniczego w postaci propanu R290.
EN
This paper outlines the research area of new heat-insulating materials useful for the production of sandwich plate for building isothermal bodies. It also presents the inappropriate solutions of construction nodes causing the occurrence of heat leakage bridges, and thus the increase of the value of overall heat-transfer coefficient (of the whole body). The last part of the paper presents the advancement procedure for the prototype isothermal body. Information obtained on the basis of the analysis of the thermovision photographs (as well as local measurements of heat-transfer coefficient values) is very important for this procedure. The presented information is connected with the realisation of the research project PBS1/B6/6/2012 “Elaboration of production technology for complete semi-trailer for food transport in refrigeration conditions of improved technological parameters” (a leader - the firm Wielton from Wielun, consortium members: Poznań University of Technology and Industrial Institute of Agricultural Machines in Poznan [2]).
PL
W artykule zarysowano obszar poszukiwania nowych materiałów termoizolacyjnych przydatnych do produkcji rdzeni płyt warstwowych w budowie nadwozi izotermicznych. Pokazano również niewłaściwe rozwiązania węzłów konstrukcyjnych prowadzące do powstania mostków ciepła, a tym samym do wzrostu wartości globalnego współczynnika przenikalności cieplnej (całego nadwozia). W ostatniej części artykułu zaprezentowano procedurę doskonalenia prototypowego nadwozia izotermicznego. W procedurze tej bardzo istotne są informacje uzyskane z analizy zdjęć termowizyjnych (oraz wyniki pomiarów lokalnych wartości współczynnika przenikania ciepła). Przedstawione informacje mają związek z realizacją projektu badawczego PBS1/B6/6/2012 „Opracowanie technologii produkcji kompletnej naczepy do przewozu żywności w warunkach chłodniczych o ulepszonych parametrach technicznych” (lider - firma Wielton z Wielunia, konsorcjanci: Politechnika Poznańska i Przemysłowy Instytut Maszyn Rolniczych w Poznaniu [2]).
PL
W węzłach tarcia sprężarek chłodniczych zazwyczaj znajduje się mieszanina oleju i czynnika chłodniczego. Ilość czynnika chłodniczego w oleju smarowym zależy od temperatury mieszaniny oraz od ciśnienia czynnika chłodniczego. W celu określenia wpływu obecności czynnika chłodniczego w oleju smarowym na wielkość zużycia elementów sprężarek chłodniczych w warunkach laboratoryjnych, należy odzwierciedlić parametry pracy węzłów tarcia. Do badań tribologicznych przygotowane zostało prototypowe stanowisko badawcze z węzłem tarcia typu block-on-ring oraz z komorą wysokociśnieniową pozwalającą symulować warunki pracy sprężarek chłodniczych. W artykule przedstawiono wyniki badań zuzyciowych dla olejów do sprężarek chłodniczych w mieszaninie z czynnikiem chłodniczym R134a.
EN
Friction nodes in refrigeration compressors are lubricated with a mixture of lubricating oil and refrigerant. The concentration of refrigerant in oil depends on temperaturę and pressure of the refrigerant. Determining the effect of this mixture on the size of wear in refrigeration compressors in laboratory conditions is only possible through an accurate reflection of friction parameters. The authors managed to prepare the prototype stand to tribological test with a model block-on-ring friction node and the high-pressure chamber allowing for simulated conditions in refrigeration compressors. The present paper includes wear research of refrigeration oils under HFC-134a environment.
EN
Elements of refrigeration compressors may be exposed to various types of wear pro¬cesses, depending on the used oils and refrigerants. The presence of the refrigerant makes the lubricating properties and anti-oil mixture - factor much worse than in case of the lack of refrigerant oil. Current regulations on the use of ODS phase-out of working require refrigeration synthetic refrigerants HCFC (e.g. popular R22). The paper presents the effect of different mixtures of oils and refrigerants on friction coefficient and surface condition of cast iron and aluminium PA6. Tests were performed on a prototype machine using frictional node type block-on-ring, which is located inside a pressure chamber that simulates the refrigeration compressor. The results of the study confirm the possibility of using green refrigerant R290 (propane) as a substitute for R22, while keeping the existing mineral oil.
PL
W artykule przedstawiono wyniki badań w zakresie doboru materiału na elementy do cięcia papryki. Jako kryterium doboru przyjęto minimalizację zużycia w warunkach jednoczesnych oddziaływań tarciowych i korozyjnych (tribokorozja). Badania wykonano na specjalistycznym stanowisku z węzłem modelowym typu pin-on-plate. Analizowano wpływ twardości stali martenzytycznej na intensywność ubytku materiału. Wyniki badań wykorzystano przy konstrukcji urządzenia do wydrążania papryki.
EN
In this paper, the results of research into material selection for knives cutting bell pepper are presented. The main criterion of selection was minimum wear rate in conditions of simultaneous abrasion and corrosion (tribocorrosion). The research was carried out on the special pin-on-plate stand. Basically, the influence of martensitic steel hardness on loss of material was tested. The results of research was used to design device to cut bell peppers.
PL
Oleje smarowe do sprężarek chłodniczych oprócz podstawowych funkcji powinny również spełniać szereg specyficznych wymagań związanych ze współpracą z czynnikiem chłodniczym w sprężarkowych urządzeniach chłodniczych. Konstrukcja powszechnie stosowanych sprężarek chłodniczych sprawia, iż nieuniknione jest powstawanie mieszaniny olejów sprężarkowych z czynnikami chłodniczymi w węzłach tarcia. Substancję smarującą stanowi więc mieszanina oleju smarowego z czynnikiem chłodniczym, a nie czysty olej smarowy. Zachowanie mieszaniny oleju smarowego z czynnikiem chłodniczym zależy od składu mieszaniny. Stężenie czynnika chłodniczego w mieszaninie zależy bezpośrednio od parametrów pracy układu (ciśnienie i temperatura) i warunkuje lepkość substancji smarującej. Istotną właściwością oleju do sprężarek chłodniczych jest zdolność do tworzenia jednorodnej mieszaniny w pełnym zakresie temperatur i ciśnień roboczych. Istnieje kilka kluczowych właściwości olejów do sprężarek chłodniczych, które należy uwzględnić przy doborze oleju. Niemożliwe jest dobranie oleju o idealnych właściwościach, co wymusza kompromisowe podejście do problemu jego doboru. W artykule przedstawiono syntetyczne zestawienie specyficznych właściwości olejów sprężarkowych w kontekście ich doboru do urządzeń chłodniczych.
EN
Lubricating oils for refrigeration compressors except for basic functions should also meet many specific requirements related to cooperation with a refrigerating medium in compressor refrigerating devices. Structure of commonly used refrigeration compressors makes it unavoidable that a mixture of compressor oils with refrigerating mediums in friction pairs is produced. Therefore, a mixture of lubricating oil with a refrigerating medium and not a clear lubricating oil constitutes a lubricating substance. Maintenance of lubricating oil mixture with a refrigerating medium depends on the composition of a mixture. Concentration of the refrigerating medium depends directly on operation parameters of the system (pressure and temperature) and conditions viscosity of the lubricating substance. A significant property of oil for refrigeration compressors is ability to form a uniform mixtures in a full range of temperatures and working pressures. There are few key properties of oils for refrigeration compressors, which shall be included at the selection of oil. It is impossible to select oil of ideal properties, which forces a compromise approach to the issue of selection. The paper presented a synthetic set of specific properties of compressor oils in the context of their selection for refrigeration devices.
PL
W artykule przedstawiono mapę zużycia ilustrującą intensywność tribokorozji stali AISI 304 w 0,5M roztworze H2SO4 w zakresie nacisków od 1 do 45 MPa przy częstotliwości wymuszeń mechanicznych od 2 do 5 Hz. Dla skrajnych wymuszeń intensywność zużywania wyznaczono eksperymentalnie. Badania wykonano na specjalistycznym stanowisku z węzłem modelowym typu pin-on-plate. Do oszacowania intensywności tribokorozji w obszarze wymuszeń pośrednich wykorzystano autorski model symulacyjny. Uzyskana mapa zużycia pozwala określić wpływ warunków eksploatacji na intensywność usuwania materiału w węźle ślizgowym podczas tribokorozji.
EN
The article presents the concept of the creation of wear maps for the tribocorrosion process in pin-on-plate combination for stainless steel. The developed wear map shows the rate of tribocorrosion wear for AISI 304 steel in 0.5M solution of H2SO4 in the pressure range of 1 to 45 MPA and the frequency of mechanical forces from 2 to 5 Hz. For marginal forces, the wear intensities were calculated experimentally. The tests were carried out on a stand equipped with sliding pair type pin-on-plate. For estimation of intermediate values of forces, the authors devised and applied a simulation model. The developed wear map presents the influence of utilisation for the rate of material removal in sliding pairs under tribocorrosion conditions.
PL
W artykule przedstawiono wyniki badań zużywania tribokorozyjnego stali AISI 304 w 0,5M roztworze H2SO4. Badania wykonano na prototypowym stanowisku typu pin-on-plate zaprojektowanym w Instytucie Maszyn Roboczych i Pojazdów Samochodowych Politechniki Poznańskiej. Węzeł modelowy stanowi twardy, nieodkształcalny trzpień, który ślizga się ruchem posuwisto-zwrotnym po powierzchni próbki na dystansie około 6 mm. Stanowisko wyposażono w układ do polaryzacji próbki zadanym potencjałem i pomiaru prądu z obszaru tarcia. Celem eksperymentu była analiza wpływu na intensywność ubytku materiału w warunkach tribokorozji następujących wymuszeń: nacisk nominalny, częstotliwość przemieszczeń trzpienia, potencjał polaryzacji, średnica trzpienia.
EN
The paper presents the results of tests of tribocorrosion wear of stainless steel AISI 304 in solution of 0.5M H2SO4. The experiments were carried out on a technical stand with a model pair type pin-on-disc. The stand was designed and implemented in the Institute of Machines and Motor Vehicles of Poznań University of Technology. The model system consists of a hard and non-deformable pin, which slides in reciprocating motion on the sample surface, which is made of steel susceptible to passivation. The analysis of the influence of the following factors was the aim of the experiment on the intensity of the decrease of material in conditions of tribocorrosion: nominal pressure, frequency of the stroke of the pin, and the applied potential the diameter of the pin.
PL
Olej chłodniczy mający za zadanie smarowanie sprężarek oprócz podstawowych funkcji, czyli odprowadzania ciepła powstającego w szczelinach smarowniczych, przeciwdziałania zużywaniu się współpracujących elementów i uszczelniania przestrzeni roboczej sprężarki, powinien w odpowiedni sposób zachowywać się w kontakcie z czynnikiem chłodniczym. W węzłach tarcia sprężarek chłodniczych najczęściej znajduje się mieszanina oleju smarowego i czynnika chłodniczego, która w zależności od zmiennych parametrów roboczych (ciśnienie, temperatura i skład mieszaniny) może przyjmować postać: dwóch cieczy wzajemnie mieszalnych, dwóch cieczy stanowiących niemieszalne fazy (rozwarstwionych) oraz oleju w fazie ciekłej i czynnika chłodniczego w postaci pary nasyconej. Zużywanie elementów sprężarek zależy od rodzaju mieszaniny smarującej węzły tarcia. W artykule przedstawiono problematykę wpływu zmienności parametrów roboczych w węzłach tarcia na rodzaj mieszaniny smarującej oraz przegląd sporządzanych charakterystyk stanowiących podstawę do określania jakości mieszaniny smarującej.
EN
Lubricant oil in refrigeration installation should fulfil some basic requirements (lubrication, sealing, cooling parts). Moreover, lubricant oil should behave in an appropriate way to in contact with the refrigerant. In friction nodes of refrigeration compressors is almost always the mixture of lubricant oil with refrigerant. The form of this mixture depends on a few parameters like temperature pressure and mixture composition. The mixture can consist of two miscible liquid phases, two immiscible liquid phases, or gas refrigerant dissolved in liquid lubricant oil. The wear value of moving parts in refrigeration compressors depends on the type of mixture that lubricates friction nodes. This paper presents the influence of changing parameters on the type of refrigerant with lubricant oil mixture as well as different charts to define the quality of this mixture.