Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Reliability Evaluation of Distribution System with Multiple Micro-Sources
EN
A new minimal path model of reliability evaluation of distribution system with multiple micro-sources is presented to analyze the effect of different type micro-source to the distribution system reliability in which the control mode of micro-source, the network configuration, operation and control characteristics of microgrid are fully considered. The results of the RBTS bus 6 verify the validity of the model and show the remarkable different effect of different type micro-source and its control mode to the reliability of distribution system.
PL
Analizowano niezawodność sieci z dołączonymi mikro-źródłami. Rozważono konfiguracje sieci oraz charakterystyki sterowania.
EN
This paper considers the problems of dynamic output feedback H[infinity] control for uncertain switched singular system with parametric uncertainties. A switching rule and a switched dynamic output feedback controller are designed to guarantee that the closed-loop system is asymptotically stable with a prescribed H[infinity] disturbance attenuation level [gamma]. Such sufficient conditions are derived via a series of strict linear matrix inequalities (LMIs). Finally, a numerical example is given to illustrate the effectiveness of the proposed method.
PL
W artykule analizuje się problem dynamiki system sterowania H[nieskończoność] dla systemu pojedynczego z niepewnymi przełączeniami. Badano zasady przełączania i dynamikę przełączania gwarantującą stabilną prace systemu. Przedstawiono przykład numeryczny ilustrujący skuteczność proponowanej metody.
3
Content available remote ANFIS Approach for Noise Reduction of Lightning Current Online Monitoring System
EN
A novel de-noising algorithm, based on adaptive neural-fuzzy inference system (ANFIS) is proposed for noise reduction of the lightning current online monitoring system. The paper presents the theory and the implement procedure of the fuzzy neural system. Comparisons among the traditional strategies, such as curve fitting (CF), wavelet transform (WT) methods and the proposed ANFIS strategy are carried out. The simulation results demonstrate the superiority of the proposed method. Moreover, the employed approach has been tested on the practical measured current of lightning current online monitoring system. The testing results validate the proposed approach.
PL
Zaproponowano nowy algorytm odszumiania bazujący na adaptacyjnym neuro-fuzzy systemie interferencji ANFIS. System zastosowano przy monitorowaniu prądu wyładowań. System porównano z innymi dotychczas stosowanymi – dopasowanie krzywej czy transformata falkowa.
EN
A highly sensitive flow injection chemiluminescent method for determination of indomethacin has been proposed. During oxidation of indomethacin by KMnO4 in polyphosphoric acid medium, chemiluminescence emission was observed, which could be enhanced more than 100 times in the presence of 4% formaldehyde. The chemiluminescence mechanism was investigated and two emitters were identified. The proposed strategy allowed for sample assay rate of 100 per l h in an automatic mode in combination with flow injection analysis. Indomethacin could be determined over the concentration range 1.0x109-1.0x 10-1 g mL<-sub>-1 with the detection limit (3σ) of 6.0 x 10<-sub>-10 g mL<-sub>-1. The relative standard deviation for determination of 1.0 x 10<-sub>-8 g mL<-sub>-1 indomethacin (n = 11) was 2.3%. The proposed method has been successfully applied to the analysis of a commercial pharmaceutical formulation without any sample pretreatment and to biological samples after their clean-up by solidphase extraction.
PL
Do oznaczania indometacyny w przepływie zaproponowano wysoko czułą metodę wstrzy-kową wykorzystującą chemiluminescencję, obserwowaną podczas utleniania indometacyny przez KMnO4 w kwasie polifosforowym. Jej intensywność wzrastała w obecności 4% formaldehydu. Badano mechanizm powstawania chemiluminescencji i zidentyfikowano jej dwa źródła. Opracowana metoda pozwalała na zbadanie 100 próbek w ciągu godziny. Indome-tacynę można by ło oznaczy ć w zakresie stężeń 1.0x 109—1.0 x l.0<-sub>-6 g mL<-sub>-1. Granicę wykrywalności (3σ) określono jako 6.0 x l0<-sub>-9 g mL<-sub>-1. Zaproponowaną metodę zastosowano z powodzeniem do analizy handlowych preparatów farmaceutycznych bez potrzeby wstępnego przygotowania próbki. Zastosowano ją również do analizy próbek biologicznych po ich oczyszczeniu metodą ekstrakcji z fazy stałej.
EN
Abandoned coal mine wastes can result in severe pollution and have aesthetic impact on the local environment. A range of reclamation techniques is available for substrate but only through the use of vegetation to stabilize coal mine wastes can complete long-term rehabilitation be achieved. Experimentation has been undertaken at coal mine sites to attempt to elucidate and overcome limitations to vegetation establishment, allowing large-scale revegetation schemes to be formulated. Although such schemes have often been successful at specific sites, their widespread application is limited owing to the great variation in physical, chemical and biological factors which exist between mine wastes. An intelligent decision system for revegetation and reclamation of coal mine wastes was developed. This paper presents a research attempt to develop and evaluate a Decision Support System (DSS) for revegetation of land contaminated from mining activates. A GIS based Decision Support System (DSS) is be ing developed and tested by China Agricultural University, which is funded by Asia IT&C programme. This paper looks at why a spatial DSS is needed and what are the advantages and difficulties in the developing and using such a system. The system's architecture and components are described. Some valuable insights into the use of GIS as a tool for decision support in decision plan for revegetation of land contaminated from mining activities are highlighted.
PL
Porzucone odpady z górnictwa węgla mogą powodować znaczące zanieczyszczenie i wpływać na estetykę środowiska lokalnego. Istnieje wiele technik rekultywacji, ale tylko wprowadzenie odpowiednich metod odnowy roślinności (rewegetacji) do stabilizacji odpadów pochodzących z górnictwa węgla może zapewnić długotrwały efekt. Prace eksperymentalne prowadzono na obszarach górnictwa węgla kamiennego w celu rozeznania i przezwyciężenia trudności związanych z odnową roślinności, co pozwoliło na przygotowanie projektu rewegetacji w skali przemysłowej. Najczęściej takie projekty rekultywacji są z powodzeniem realizowane dla jednego wybranego obszaru, lecz trudno je wdrażać w nowych miejscach ze względu na wiele zmiennych wynikających z uwarunkowań fizycznych, chemicznych, biologicznych. W artykule został zaprezentowany inteligentny system wspomagający podejmowanie decyzji przy rekultywacji obszarów zanieczyszczonych odpadami z górnictwa węgla kamiennego. Ponadto, przedstawiono model wspomagający podejmowanie takich decyzji (DOS) wykorzystujący technikę GIS, który był testowany na Uniwersytecie Rolnictwa w Chinach, a finansowany z programu Asia IT&C.
EN
A flow-injection chemiluminescence method for the determination of tobramycin, micro-nomicin, amikacin and gentamycin has been described. The method utilises chemilumines-cence of the above analytes emitted during their oxidation with N-bromosuccinimide (NBS) in alkaline medium in the presence of fluorescein. The obtained detection limits (3 Sigma) are 0.07 ug mL(-1): for tobramycin and 0.08 ug ml/1 for micronomicin, amikacin and gentamycin. The evaluated method is recommended for automated and continuous analysis- In the automated mode the samples can be analysed at the rate of 100 per h with RSD of about 2.0% for the determination of 5 ug mL (-1) of each aminoglycoside antibiotic (n= 11). The proposed method has been successfully used for the analysis of commercial pharmaceutical formulations without any sample pretreatment.
PL
Opisano przepływową, chemiluminescencyjną metodę oznaczania tobramycyny, mikrono-mycyny, amikacyny i gentaraycyny. W metodzie tej wykorzystano chemiluminescencję powstającą podczas utleniania analitów NBS w środowisku alkalicznym, wobec fluoresceiny. Otrzymane progi wykrywalności (3 o) wynosiły 0,07 ug mL (-1) dla tobramycyny i 0,08 ug mL(-1) dla mikronomycyny, amikacyny i gentamycyny. Opracowana metoda jest polecana do analiz zautomatyzowanych i ciągłych. W systemie zautomatyzowanym próbki mogą być analizowane z szybkością 100 na godziną z RSD ok. 2% dla 5 ug mL(-1) każdego antybiotyku aminoglikozydowego (n = 11). Proponowana metoda została z powodzeniem zastosowana do analizy formulae] i farmaceutycznych bez wstępnej obróbki próbki.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.