Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The Linac coherent light source (LCLS) at the SLAC National Accelerator Laboratory (SLAC) is the world’s first hard X-ray free electron laser (XFEL) and is capable of producing high-energy, femtosecond duration X-ray pulses. A common technique to study fast timescale physical phenomena, various “pump/probe” techniques are used. In these techniques there are two lasers, one optical and one X-ray, that work as a pump and as a probe to study dynamic processes in atoms and molecules. In order to resolve phenomena that occur on femtosecond timescales, it is imperative to have very precise timing between the optical lasers and X-rays (on the order of ~20 fs or better). The lasers are synchronized to the same RF source that drives the accelerator and produces the X-ray laser. However, elements in the lasers cause some drift and time jitter, thereby de-synchronizing the system. This paper considers cross-correlation technique as a way to quantify the drift and jitter caused by the regenerative amplifier of the ultrafast optical laser.
4
Content available remote Monitorowanie syntezy poliuretanu metodą FPT
PL
Zbadano przydatność technologii sond fluorescencyjnych (FPT) do monitorowania przebiegu procesów syntezy poliuretanów na przykładzie reakcji poliaddycji heksametylenodiizocyjanianu do glikolu polipropylenowego. Do roli sond fluorescencyjnych zastosowano Styryl 7, 4-dimetyloamino-4'-nitrostilben (DMANS) oraz 7-dietyloamino-4-metylokumarynę (Coumarin 1). Jako wskaźnik postępu polimeryzacji zastosowano stosunek intensywności fluorescencji (R), mierzony przy dwóch długościach fali, zlokalizowanych po obu stronach maksimum widma fluorescencji sondy. Stwierdzono, że widma fluorescencji badanych sond przesuwają się w stronę fal krótszych w miarę postępu addycji grup izocyjanianowych do hydroksylowych, co przejawiało się wzrostem wartości R. Tym samym technologia FPT umożliwia śledzenie postępu reakcji syntezy poliuretanów oraz może być z powodzeniem stosowana do kontroli stopnia utwardzenia powłok poliuretanowych stosowanych w przemyśle.
EN
Applicability of fluorescence probe technology (FPT) for monitoring of synthesis of polyurethanes by addition polymerization of diisocyanates to polyols has been evaluated, using hexamethylene diisocyanate and poly(propylene glycol) as example monomers. Styryl 7, 4-dimethylamino-4'-nitrostilbene (DMANS) and 7 -diethylamino-4-methylcoumarin (Coumarin 1) were applied as the fluorescent probes. The ratio of fluorescence intensities measured at two wavelengths located on both sides of the fluorescence spectrum maximum was applied as an indicator of the reaction progress. It was found that the fluorescence spectra of the probes studied shifted to shorter wavelength during the addition polymerization of the monomers, which resulted in increase of the ratio R. Hence, the FPT method is applicable for tracing of the progress of addition polymerization reactions used for synthesis of polyurethanes, and, it can be applied successfully for monitoring of the degree of cure of polyurethane coatings used in industry.
PL
Zbadano możliwość znakowania fluorescencyjnego nowoczesnych materiałów polimerowych dostępnym na rynku fluoroforem, w celu ich ochrony przed nieuczciwą konkurencją. Pomysł znakowania wysokojakościowych tworzyw sztucznych polega na wprowadzeniu do znakowanych tworzyw odpowiednich fluoroforów w niewielkiej ilości (<0,1%), które będą służyły jako znaczniki firmowe producentów tworzyw o określonych parametrach, w celu odróżnienia wyrobów oryginalnych od ewentualnych podróbek niespełniających wymogów. Jako znacznik fluorescencyjny zastosowano 1,4-bis(2-benzoksazolo)naftalen, a znakowanymi materiałami były szpachlówka poliestrowa oraz lakier akrylowy, które są stosowane w przemyśle motoryzacyjnym. Wyznaczono minimalne stężenie znacznika, pozwalające na wykrycie jego obecności w oznakowanym materiale.
EN
The possibility of marking of modem polymeric materials with a commercially available fluorophore, for the purpose of protection of the material manufacturers against non-fair competitors, has been evaluated. The idea relies on marking of high-quality polymeric products with fluorescent markers, which will be added to the polymers at low concentration (<0,1 %). Such markers will serve as identifiers of the product manufacturers to distinguish original high-quality products from potential counterfeits, which do not meet quality requirements. 1,4- Bis(2- benzoxazolyl)naphthalene was tested as the fluorescent marker for an acrylic lacquers and a polyester putty used in automotive industry. The minimal concentration of the marker, which allows detection of its presence in marked polymer has been determined.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.