EN
This paper presents an analysis of the effect of concrete salinity on the splitting tensile strength of specimens taken directly from the HC-500 floor slab and the flexural and compressive strength and the value of the modulus of elasticity of specimens made under laboratory conditions from lightweight concrete and ordinary concrete. The tests were carried out in two variants: in the first, chloride ions were introduced into the concrete by the migration method and in the second, as an additive introduced directly with the batch water. The analysis showed that the additive can affect certain mechanical properties of concrete both favorably and unfavorably. The results indicate that it is important to examine the issue of the influence of salinity on concrete’s mechanical properties. This knowledge can be applied to the modeling of damage in reinforced concrete structures resulting from exposure to chloride-rich environments.
PL
W niniejszej pracy przedstawiono analizę badań wpływu zasolenia betonu na wytrzymałość na rozciąganie przy rozłupywaniu próbek pobranych bezpośrednio z płyty stropowej HC-500 oraz wpływu zasolenia na wytrzymałość na zginanie i ściskanie oraz na wartość modułu sprężystości próbek wykonanych w warunkach laboratoryjnych z betonu lekkiego i betonu zwykłego. Badania przeprowadzono w dwóch wariantach: w pierwszym po wprowadzeniu jonów chlorkowych do betonu metodą migracyjną w próbkach pobranych z płyt HC-500 i wykonanych z betonu lekkiego i w drugim, jako dodatek wprowadzony bezpośrednio z wodą zarobową w próbkach z betonu zwykłego. Przeprowadzone badania porównawcze różnych betonów z dodatkiem NaCl wykazały, że dodatek ten może wpływać zarówno korzystnie, jak i niekorzystnie na niektóre właściwości mechaniczne betonu. Przeprowadzone badania wskazują, że istotne jest dokładniejsze rozpoznanie zagadnienia wpływu zasolenia betonu na jego właściwości mechaniczne, co może być następnie wykorzystane w procesie modelowania zniszczeń konstrukcji żelbetowych wywołanych oddziaływaniem środowiska zawierającego chlorki.
PL
W pracy wyznaczono wartości współczynników dyfuzji chlorkóww betonach zwykłych wykonanych z wykorzystaniem trzech różnego typu powszechnie stosowanych cementów: CEM I 42,5 R, CEM II/B-V 32,5 R oraz CEM I 42,5 N/SR3/NA wg obowiązujących norm NT BUILD 443, AASHTO T 259, ASTM C 1556 – 03. Wyznaczone wartości porównano z uzyskanymi na podstawie krótkich, migracyjnych badań tych betonów z wykorzystaniem termodynamicznego modelu migracji przy zastosowaniu rozwiązania zadania odwrotnego równania migracji chlorków w betonie. Dodatkowo wyznaczono wartości współczynników migracji jonów chlorkowych według normy NT BUILD 492 oraz metodą zaproponowaną przez Andrade. Porównanie uzyskanych wartości współczynników dyfuzji i migracji pozwoliło na ocenę przydatności stosowania obowiązujących metod normowych oraz odniesienie ich do metody wyznaczania współczynnika dyfuzji według termodynamicznego modelu migracji.
EN
This article describes how diffusion coefficients of chlorides were determined in ordinary concretes using three different types of commonly used cement: CEM I 42.5 R, CEM II/B-V 32.5 R and CEM I 42.5 N/SR3/ NA according to applicable standards NT BUILD 443, AASHTO T 259, ASTM C 1556 – 03. Determined values were compared with values obtained from short migration tests on these concretes using the thermodynamic migration model with the inverse equation for chloride migration in concrete. Additionally, migration coefficients of chloride ions were determined according to the standard NT BUILD 492 and applying a method proposed by Andrade. This comparison of obtained values of diffusion and migration coefficients was used to evaluate the suitability of valid standard methods and their reference to the method of determining diffusion coefficient according the thermodynamic model of migration.
3
Content available remote Szacowanie wartości współczynnika ekstrakcji chlorków z betonu
PL
W pracy szacowano wartość współczynnika ekstrakcji chlorków z betonu na podstawie zmian stężenia jonów chlorkowych w betonie. Przeprowadzono badania elektrochemicznej ekstrakcji jonów chlorkowych z betonu zwykłego wykonanego z zastosowaniem cementu portlandzkiego CEM I 42,5 R. Wyznaczono wartości stężenia jonów chlorkowych w betonie poddanym procesowi ekstrakcji chlorków w dwóch różnych czasach. Na podstawie zmiany w czasie rozkładu stężenia jonów chlorkowych na grubości otuliny betonowej oszacowano wartość współczynnika ekstrakcji jonów chlorkowych. Uzyskane wartości współczynnika ekstrakcji wykorzystano w celu określenia skutecznego czasu trwania ekstrakcji, pozwalającego na całkowite usunięcie jonów chlorkowych będących główną przyczyną korozji stali zbrojeniowej, ze struktury betonu.
EN
The coefficient of chloride extraction from concrete was estimated for the purpose of this paper on the basis of variations in concentration of chloride ions in concrete. Electrochemical tests were conducted on extraction of chloride ions from ordinary concrete containing Portland cement CEM I 42.5 R. Those tests were used to determine concentrations of chloride ions in concrete exposed to chloride extraction at two different times. A change in time of concentration distribution of chloride ions over the thickness of concrete cover was used to estimate the coefficient of chloride ions extraction. Determined values of extraction coefficient were used to establish the duration of extraction sufficient for the complete removal of all chloride ions from concrete, which were responsible for corrosion of reinforcing steel.
PL
W artykule zaprezentowano analizę statyczną płyt stropowych typu HC-500 w warunkach zagrożenia agresją chlorkową z uwzględnieniem utraty przyczepności i zmniejszenia przekroju czynnego cięgien spowodowanych postępującą korozją wżerową. Wykorzystano współczynnik dyfuzji wyznaczony na podstawie termodynamicznego modelu migracji i badań własnych. Wpływ agresji chlorkowej uwzględniono, dokonując adaptacji znanych z konstrukcji żelbetowych zależności opisujących ubytek średnicy zbrojenia. Wykorzystując zalecenia EC-2, uwzględniono zmianę przyczepności cięgien, a w efekcie zmianę siły sprężającej w przekroju. Obliczono czas, po którym można spodziewać się całkowitej utraty przyczepności oraz wzrostu naprężeń spowodowanego zmniejszeniem pola przekroju.
EN
The aim of the work was the evaluation of forecasting method concerning the durability of prefabricated floor HC-500 slabs in conditions of danger of chloride ions aggression taking into consideration values of diffusion coefficient of concrete taken directly from prefabricated slabs. Diffusion coefficient obtained on the basis of thermodynamic migration model and own research. The influence of chloride aggression was taken into account when making adaptations known from reinforced concrete structures describing the reinforcement diameter loss, using EC-2 recommendations, changes in the adhesion of the tendons and, as a result, changes in the prestressing force in the cross-section were taken into account. The time after which total loss of adhesion and an increase in stress due to a decrease in cross-sectional area can be expected was calculated.
PL
Artykuł dotyczy oceny metody prognozowania trwałości płyt stropowych typu HC-500 w warunkach zagrożenia agresją chlorkową z uwzględnieniem wartości współczynnika dyfuzji chlorków z betonu pobranego bezpośrednio z płyt prefabrykowanych. Wykorzystano współczynnik dyfuzji wyznaczony na podstawie termodynamicznego modelu migracji i badań własnych oraz wartość współczynnika zalecaną wg norm wzorcowych fib Model-Code 2006 i fib Model-Code 2010 wyznaczoną na podstawie badania własnego wg normy NT BUILD 492.
EN
The article focus on the evaluation of forecasting method concerning the durability of prefabricated floor HC-500 slabs in conditions of danger of chloride ions aggression taking into consideration values of diffusion coefficient of concrete taken directly from prefabricated slabs. Diffusion coefficient obtained on the basis of thermodynamic migration model and own research and recommended by draft of norms fib Model-Code 2006 and fib Model-Code 2010 coefficient value obtained on the basis of own research in accordance with NT BUILD 492 were used.
PL
Celem pracy była analiza wyznaczonych wartości współczynnika dyfuzji i migracji chlorków z betonu pobranego bezpośrednio z prefabrykowanych płyt strunobetonowych typu HC-500. Do analizy wykorzystano wartości współczynników dyfuzji i migracji wyznaczone metodami normowymi oraz wg termodynamicznego modelu migracji. Rozważane współczynniki dyfuzji i migracji bardzo istotnie różnią się od siebie. Porównano wartości błędu średniokwadratowego między wartościami stężenia jonów chlorkowych wyznaczonymi na podstawie rozwiązania równania dyfuzji z zastosowaniem współczynników dyfuzji określonych różnymi metodami a wartościami pomierzonymi w badaniach dyfuzyjnych.
EN
The aim of the work was analysis of the determained diffusion coefficient values and chlorides migration in concrete which was taken directly from prefabricated prestressed HC-500 slabs. Diffusion coefficient and migration values used in the analysis were determined in accordance with the norm and thermodynamic migration model. Said diffusion coefficient and migration coefficient are significantly different. Values of mean square error between values of chloride ions concentration and values determined by the diffusion research were compared. Chloride ions concentrations were determined based on the solution of diffusion equation with the use of diffusion coefficients determined with various methods.