This paper proposes a methodology to identify the reactive and harmonic compensation in three-phase power systems. Considering the behavior of power factor, current and voltage harmonic distortion, unbalance factors and reactive power daily variation, the developed tool is able to select two suitable solutions for power factor correction on the installation under analysis. The results gathered from computational simulations, as well as from measuring an industrial facility are presented and discussed. Based on specialist knowledge the developed tool may be very useful for finding the correct compensation solution quickly even manipulating a large amount of data.
PL
Artykuł proponuje metodykę identyfikacji kompensacji mocy biernej I harmonicznych. Biorąc pod uwagę dzienne zmiany współczynnika mocy, odkształcenia prądów i napięć, współczynników niezrównoważenia oraz mocy biernej, przedstawiona metoda jest w stanie wybrać dwa odpowiednie rozwiązania dla poprawy współczynnika mocy w analizowanym systemie. W artykule przedstawione są i przedyskutowane wyniki zebrane z modelowania komputerowego oraz z pomiarów na obiektach przemysłowych. W oparciu o specjalistyczną wiedzę, przedstawiona metoda może być bardzo użyteczna w szybkim poszukiwaniu poprawnej kompensacji, nawet w przypadku dużej ilości danych.
2
Content available remote Load Analyser using Conservative Power Theory
EN
This paper deals with the analysis and application of novel conformity factors, defined by means of the Conservative Power Theory (CPT), for the purpose of load analysis and characterization. Basically, such factors are able to describe the influence of different load characteristic on the power factor calculation and they are valid under generic load and supply voltage conditions. Moreover, the development of a flexible smart-meter prototype has been described and used to the experimental validation of all power components and conformity factors considered on the paper.
PL
W artykule zaprezentowano analizę i zastosowanie nowego współczynnika zgodności zdefiniowanego na podstawie Teorii Zachowania Mocy CPT. Współczynnik zastosowano do analizy obciążeń iich wpływu na współczynnik mocy. Opisano też nową koncepcję miernika typu smart.-meter.
3
Content available remote Design of Static var Compensators using a General Reactive Energy Definition
EN
This paper describes a methodology to design Static var Compensators (SVC) using the reactive energy definition from the Conservative Power Theory. The application of this methodology is presented through simulations of local and distributed compensation scenarios. Results show effective compensation of reactive current and load unbalance. Moreover, the harmonic distortion caused by thyristor controlled reactor has been suitable attenuated by passive filters designed in combination with the SVC.
PL
Opisano metodologię projektowania kompensatora mocy biernej SVC wykorzystującą definicję energii biernej z Teorii Konserwacji Mocy. Symulacje wykazały że układ kompensuje prąd bierny i nierówność obciążenia. Tłumione są także harmoniczne.