Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
Evolution of residual stress and its components with increasing temperature in chemical vapor deposited (CVD) diamond films has a crucial impact on their high temperature applications. In this work we investigated temperature dependence of stress in CVD diamond film deposited on Si(100) substrate in the temperature range of 30 degrees C to 480 degrees C by Raman mapping measurement. Raman shift of the characteristic diamond band peaked at 1332 cm(-1) was studied to evaluate the residual stress distribution at the diamond surface. A new approach was applied to calculate thermal stress evolution with increasing temperature by using two commonly known equations. Comparison of the results obtained from the two methods was presented. The intrinsic stress component was calculated from the difference between average values of residual and thermal stress and then its temperature dependence was discussed.
PL
Pomiary śladowych stężeń gazów są ważne dla przemysłu, ochrony środowiska, medycyny oraz bezpieczeństwa. Pomiary te można zrealizować z wykorzystaniem laserowej spektroskopii absorpcyjnej z modulacją długości fali lasera półprzewodnikowego. W pracy opisane zostały badania istotnych parametrów, wykorzystanego do pomiarów stężeń gazów, kwantowego lasera kaskadowego. Podczas badań wyznaczono charakterystyki mocy lasera w funkcji natężenia prądu zasilającego. Zostały one zarejestrowane w wybranych temperaturach jego pracy. Następnie zbadano charakterystykę strojenia częstotliwościowego lasera za pomocą germanowego etalonu Fabry -Perot. Ponadto przedstawiona została metoda poprawy parametrów wiązki lasera. Metoda ta polegała na zastosowaniu w układzie filtra przestrzennego, którego zasada działania i konstrukcja zostały opisane w niniejszej pracy.
EN
Setups for measuring the concentrations of gases are important from a practical point of view. These measurements can be performed using wavelength modulation absorption spectroscopy. This paper describes the study of important parameters of quantum cascade laser, used for measuring concentrations of gases. During the tests the characteristics of the laser power as a function of current supply were measured at selected work temperatures. Then, examined changes in the power of the laser radiation in response to the modulation of supply current. Furthermore, the a spatial filter has been applied to achieve a Gaussian profile of the laser intensity. Filter operation procedure and its construction were also described.
EN
In Langmuir monolayers the central Mg-atom of bacteriochlorophyll c is an important factor influencing the ability of the pigment to interact with the subphase and its aggregation properties. As follows from analysis of the isotherms, the spatial arrangement of bacteriochlorophyll c ring is beneficial for ligation of water molecules to Mg-atom at low pressures when the ring makes a small angle with the subphase surface, while the low values of the compressibility modulus suggestthat the twodimensional fluid phase of the pigment molecules cannot be compressed into a solid one.
PL
Analiza zarejestrowanych izoterm (π-A) dla bakteriochlorofilu c pozwoliła na określenie orientacji pierścienia porfirynowego oraz odległości jonu magnezu od powierzchni subfazy w warstwach Langmuira. Stwierdzono, że w monomolekularnych warstwach wytworzonych na granicy faz obecność jonu Mg skompleksowanego z pierścieniem ma istotny wpływ na oddziaływania międzymolekularne. W przypadku bakteriofeofityny obserwuje się załamanie monowarstwy, a bakteriochlorofilu c, będącego w warstwie Langmuira w fazie dwuwymiarowej cieczy, nie można sprężyć do fazy stałej, co sugerują obliczone niskie wartości modułu ściśliwości.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.