Content available remote Condition analysis of electrical machines by thermovision
EN
This article deals with problems of prophylactic measurement and condition of electrical machines using thermovision diagnostics. It examines the basic principles and uses non-contact temperature measurement. The knowledge of the problems of diagnostic of electrical machines in service without disassembly enables us to use more efficient thermo-diagnostic methods and to localize the failures that determine the quality of electrical wiring and equipment. The degradation of insulation materials due to temperature puts increased demands on precise knowledge of the thermal conditions in a given electrical machine. In the article are presented thermovision experimental measurements on asynchronous motor, transfer power transformer 242 kV and high-voltage generator 220 MW. Except for analysis of failures of listed power devices, thermovision technology was also used for checking of electric machines and devices for detecting of the temperature on the pick-up systems and excitation systems of generators, power parts of electric machines, detecting of the temperature differences on the semiconductor valves in individual parallel branches of equipment.
PL
W artykule zaprezentowano wykorzystanie termowizji do profilaktyki i diagnostyki maszyn elektrycznych. Metoda pozwala na ocenę stanu uzwojeń I wykrywanie błędów bez przerywania pracy urządzenia. Badano silnik asynchroniczny, transformator I generator.
2
Content available remote Analysis of transformer condition by frequency and time methods
EN
Article presents theoretical and experimental analyses of possible mechanical effect of short-circuit currents on the transformer winding by frequency and time methods. The first part of the paper is focused to mechanical influence of radial and axial forces during short-circuit. These dangerous forces cause mechanical stress in transformer. Above analysis shows that it is necessary to know the size of short-circuit current, because it represents a danger for the operation of transformer. Finally, the article presents experimental methods of diagnostics for analysis of the short-circuit forces on transformer winding by frequency method SFRA and time method – impact test.
PL
W artykule przedstawiono teoretyczne i eksperymentalne analizy, w dziedzinie czasu i częstotliwości, mechanicznego wpływu prądów zwarciowych na uzwojenie transformatora. Pierwsza część artykułu koncentruje się na mechanicznym oddziaływaniu sił promieniowych i osiowych podczas zwarcia. Te niebezpieczne dla transformatora siły powodują naprężenia mechaniczne. Przedstawiona analiza pokazuje, że konieczna jest znajomość wartości prądu zwarciowego, ponieważ stanowi on zagrożenie dla pracy transformatora. Artykuł przedstawia eksperymentalne metody diagnostyczne, wykorzystywane do analizy wpływu sił zwarciowych na uzwojenia transformatora, wykorzystujące częstotliwościową metodę SFRA i czasową – test udarowy.