Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 25

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The aim of the paper is to present the possibilities and limitations of using the Digital Image Correlation systems. In order to assess the measurement inaccuracies the measuring volume 1250 × 1100 mm was analysed using two cameras with sensor resolution 6 megapixels. It was stated very good accuracy of the line segment length change. It causes that observation of crack widths can be considered as precisely. Some practical information concern how determine the compatibility between crack width measured traditionally and by using DIC are given. In the second part of the paper the results of the tests concerning capacity of interface between two concrete casting at the same time were presented. Use of the optical measurement system Aramis enables the analysis of the deformation, determination of failure mode of the tested specimens and limit displacement between edges of the interface.
PL
Celem artykułu jest przedstawienie możliwości i ograniczeń stosowania systemów cyfrowej korelacji obrazu (CKO). W celu oceny niedokładności pomiaru przeanalizowano pole pomiarowe o wymiarach 1250 x 1100 mm, wykorzystując dwa aparaty o rozdzielczości matryc 6 megapikseli. Stwierdzono bardzo dobrą dokladność wyznaczenia zmiany długości odcinka. Dzięki temu obserwację szerokości rys można uważać za dokładną. W artykule zawarto praktyczne informacje dotyczące tego, w jaki sposób prowadzić pomiar szerokości rozwarcia rys za pomocą CKO. W drugiej części artykułu przedstawiono wyniki badań dotyczących nośności styku elementów betonowanych w tym samym czasie. Zastosowanie optycznego układu pomiarowego Aramis umożliwiło analizę odkształcenia, określenie sposobu zniszczenia badanych próbek i granicznych przemieszczeń między krawędziami połączenia.
PL
W ostatnich latach szczególnego znaczenia nabierają procesy suszenia osadów. Z jednej strony są skuteczną metodą zmniejszenia masy (i objętości) odpadów z oczyszczalni, a z drugiej strony stanowią przygotowanie przed ich dalszym, termicznym unieszkodliwianiem. Wśród tych metod obiecującym rozwiązaniem wydaje się wykorzystywanie darmowej energii w słonecznych suszarniach osadów ściekowych. W ramach niniejszego artykułu przeprowadzono badania w rzeczywistych obiektach suszarniczych w celu oceny efektywności ich pracy w pełnym cyklu rocznym. Badania wykazały lepszą efektywność pracy suszarni hybrydowych niż klasycznej. Stwierdzono również, że zastosowanie dodatkowego wspomagania cieplnego procesu suszenia nie umożliwia zrekompensowania deficytu energii słonecznej w miesiącach zimowych.
EN
The solutions, which are recently gaining more enthusiasm, are the methods of sludge drying. On the one hand are an effective methods of reducing the weight (and volume) of wastes from wastewater treatment plant, on the other hand they are preparing way before their further thermal utilization. An promising solution seems to be using of free energy in solar sewage sludge dryers. In this paper was carried out experiment in full scale in drying facilities to assess their effectiveness during the full annual cycle. Studies have shown that hybrid dryers give results better than conventional one. It has also been found that the use of additional solar-heated drying does not compensate for the energy deficit of solar energy in the winter months.
PL
Ważnym źródłem energii odnawialnej (OZE) jest biomasa, z której podczas procesu fermentacji beztlenowej powstaje gaz fermentacyjny (biogaz). Celem pracy była analiza składu biogazu pochodzącego z różnych grup instalacji fermentacyjnych, zwłaszcza pod kątem jego energetycznego wykorzystania. Próby były pobrane z różnych obiektów takich jak: komunalne oczyszczalnie ścieków (fermentacja osadów ściekowych), beztlenowe oczyszczalnie ścieków przemysłowych, biogazownie rolnicze (energetyczne i utylizacyjne), składowiska odpadów oraz instalacje zaawansowanych technologii przetwarzania odpadów komunalnych. Zawartość metanu oraz wartość opałowa są najważniejszymi parametrami wskazującymi na możliwość energetycznego wykorzystania biogazu. Udział metanu w poszczególnych próbach zmieniał się w dość szerokim spectrum, od 38 do 74% obj. Z kolei wartość opałowa mieściła się w granicach 13,8-26,7 MJ/kg. Najmniej korzystne parametry zanotowano dla biogazu składowiskowego, natomiast najwyższe dla prób pochodzących z oczyszczalni ścieków przemysłowych. Najlepszym „jakościowo” substratem do produkcji biogazu okazały się osady ściekowe oraz stężone ścieki pochodzące z sektora przemysłu rolno-spożywczego, natomiast najmniej przydatnym - odpady komunalne oraz materiał wsadowy do biogazowni.
EN
An important source of renewable energy is biomass, which produces fermentation gas (biogas) during the anaerobic fermentation process. The aim of the study was to analyze the composition of biogas derived from various groups of fermentation instalations, especially in terms of its energetic use. Samples were taken from various objects such as municipal sewage treatment plants, anaerobic industrial sewage treatment plants, agricultural biogas plants, landfills and advanced municipal waste treatment technologies. Methane concentration and calorific value are the most important parameters indicating the potential for energetic using of biogas. The methane content in the individual samples varied from 38 to 74% vol. The calorific value was in the range of 13.8-26.7 MJ/kg. Worst parameters were observed for landfill biogas, and the highest for industrial wastewater treatment plants. The best "qualitative” substrate for biogas production were sewage sludge and concentrated wastewater from the agro-food sector, while the least useful - municipal waste and substrate to biogas plant.
EN
In the paper experimental investigation results of three elements are presented. Two of them were made of reinforced concrete. The strengthened bracket had the steel accessory mounted to cracked loaded corbel (while it was loaded to half ultimate force of the reference element), the reference one was tested without any accessory. The third corbel was the steel accessory mounted to the concrete column. Full scale corbels were 450 mm deep and 250 mm wide, steel accessory was 320 mm high. The aim of the research was to verify the following thesis: short corbels (shear slenderness ac/h ≈ 0,3) can be strengthened by a steel accessory. Load carrying capacity of strengthened member increased by 40 %. The ultimate force obtained for the steel accessories mounted to concrete column was 66 % of reference value. While testing some observations and measurements (strain of reinforcement and concrete, development of cracking) were made which allowed to describe corbel behaviour under increasing load.
PL
Problematyka wzmacniania wsporników żelbetowych była podejmowana przez różne ośrodki badawcze na świecie. Do elementów montowano dodatkowe zbrojenie stalowe bez przyczepności do betonu lub przyklejano taśmy bądź maty z włókien CFRP. Na podstawie przytoczonych prac można stwierdzić, że niszczenie modeli wzmocnionych CFRP przebiega gwałtownie, jest niesygnalizowane a nośność wsporników jest ograniczana przyczepnością taśm lub mat do betonu. Badano również wsporniki z wklejonymi prętami stalowymi. Kolejnym sposobem na wzmacnianie wsporników jest użycie stalowego akcesorium zamocowanego za pomocą prętów wklejonych do słupa. Do badań prezentowanych w niniejszym artykule przygotowano trzy elementy. Dwa wsporniki wykonano jako elementy żelbetowe o wysokości 450 mm, szerokości 250 mm, stopniu zbrojenia podłużnego ρl ≈ 0,6% oraz smukłości ac/d ≈ 0,3. Oprócz zbrojenia głównego zastosowano w nim cztery dwucięte strzemiona wykonane z pręta ϕ 8. Element F – I obciążono i utrzymując siłę zewnętrzną wzmocniono poprzez zamontowanie akcesorium stalowego za pomocą gwintowanych prętów wklejonych M20. Wspornik referencyjny (F – 0) zbadano bez zastosowania elementu wzmacniającego. Element F – II wykonano jako słupek, do którego zamocowano identyczne jak w F – I elementy stalowe. Elementy badano w pozycji obróconej obciążając je symetrycznie.
EN
In the paper the results of authors’ experimental investigations concerning punching shear of flat slabs made from lightweight concrete with "CERTYD" aggregate were presented. This aggregate is manufactured from fly ash accumulated in electrostatic precipitators and ash-slag mixture from wet furnace waste generated in the process of burning hard coal in a combined heat and power plant. A total of six specimens with dimensions of 2400 x 2400 x 200 mm were tested. The slabs were connected with short fragments of columns of a cross-section of 250 x 250 mm and a height of 150 mm. The main variable parameter was slab longitudinal reinforcement ratio ρl, equal to 0.47, 0.86 and 1.23% intentionally. One of the pair of models with the same longitudinal reinforcement was the control specimen and did not contain shear reinforcement.
PL
W pracy przedstawiono wyniki własnych badań eksperymentalnych dotyczących przebicia płaskich płyt z betonu lekkiego, wykonanego na kruszywie „CERTYD”, produkowane przez firmę LSA sp. z o.o. z Białegostoku. Kruszywo to powstaje z popiołów lotnych zgromadzonych w elektrofiltrach i mieszanki popiołowo-żużlowej z mokrego usuwania odpadów piecowych, wytwarzanych w procesie spalania węgla kamiennego w elektrociepłowni. Zbadano 6 modeli płyt płaskich o wymiarach 2400 x 2400 x 200 mm, połączonych z krótkimi fragmentami słupów o przekroju 250 x 250 mm i wysokości 150 mm. Głównym parametrem zmiennym był stopień zbrojenia podłużnego ρl, równy w zmierzeniu 0,47, 0,86 oraz 1,23%. Jeden z pary modeli o tym samym stopniu zbrojenia stanowił element odniesienia dla modelu zbrojonego na przebicie.
PL
Przyjęte uproszczenia obliczeniowe stropu oraz nadmierne oszczędności poczynione na etapie projektu wykonawczego były przyczyną zagrożenia awaryjnego nowo wznoszonego obiektu przemysłowego. Podstawowym błędem było nieuwzględnienie podatności stalowego rusztu, na którym oparto strop zespolony typu filigran. Przedstawiono analizę problemu i projekt wzmocnienia.
EN
Too serious simplifications and irrational savings had been made while detailed design documentation was prepared. As a result newly construct industrial building was close to failure. The basic mistake resulted from assuming that the steel grate is a rigid support for reinforced concrete, composite floor slab (type “filigran”). Authors of the paper present results of the analysis and the concept of strengthening which was realized under their supervision.
PL
Omówiono zasady kształtowania powiązań wewnętrznych w stropach płytowo-słupowych. Przedstawiono reguły obliczania wymaganego zbrojenia wieńców według zasad europejskich, amerykańskich i kanadyjskich. Zamieszczono przykład obliczeniowy, ilustrujący sposób prowadzenia obliczeń zgodnie z przytoczonymi zasadami. Na podstawie wyników obliczeń dokonano porównania zbrojenia w powiązaniach wewnętrznych i zewnętrznych.
EN
The principles of detailing of internal ties for flat slabs were discussed in the paper. The rules of calculating the amount of required reinforcement according to the European as well as American and Canadian code provisions were shown. A working example presenting how to design the reinforcement according to the referenced procedures was presented. Based on the results of calculations the demands for the reinforcement of internal and external tying systems were compared and discussed.
PL
W artykule przedstawiono zagadnienie nośności betonu w elemencie z uwagi na przecinanie. Rozważano modele ze „stykami” zbrojonymi i niezbrojonymi. Stwierdzono, iż wprowadzenie zbrojenia poprzecznego do hipotetycznej powierzchni zniszczenia umożliwia zmianę mechanizmu zniszczenia z kruchego na ciągliwe, czemu towarzyszy wyraźny wzrost nośności – w rozważanych badaniach dochodził on do 80% w odniesieniu do elementu ze stykiem niezbrojonym. Dokonano porównania wyników badań eksperymentalnych w świetle procedur obliczeniowych Eurokodu 2 i Model Code 2010, odnoszących się do naprężeń granicznych w styku pomiędzy betonami układanymi w różnym czasie. Okazały się bardzo zachowawcze w stosunku do styków w pełni monolitycznych. Procedury normowe zaniżyły wpływ sił przyczepności (adhezji) i zazębiania kruszywa w odniesieniu do elementów wykonanych z tego samego betonu. Skutkiem tego nośności eksperymentalne były nawet 3,5 – krotnie wyższe od wartości ustalonych zgodnie z procedurami normowymi. Dzięki zastosowaniu aparatu do pomiarów optycznych ARAMIS, możliwa była dokładna analiza odkształceń ciał próbnych i określenie granicznych przemieszczeń krawędzi styku.
EN
The paper presents the issue of carrying capacity of interface between two concrete casting at the same time. The author’s experimental investigations concerning specimens with and without shear reinforcement are presented and discussed. Comparison of experimental and theoretical carrying capacity shows that provisions of Eurocode 2 and Model Code 2010 may lead to underestimation of the ultimate shear stresses in the interface between concretes casting at the same time. Use of the optical measurement system ARAMIS enables the analysis of the deformation and determination of the tested specimens and limits displacement between edges of the interface.
PL
Celem niniejszego opracowania jest omówienie niedokładności pomiarowych systemu Aramis. Ze względu na złożoność zagadnienia trudno jest znaleźć rozwiązanie ogólne. Do celów aplikacyjnych stosowana jest metoda polegająca na porównywaniu wielu zdjęć przedstawiających jeden stan powierzchni. W artykule zaprezentowano analizę niedokładności dla pola pomiarowego 1250 × 1100 mm. Rozrzut wyników rejestrowany przez system Aramis jest miarą błędu pomiaru. Stwierdzono, że odczyty z map odkształceń obarczone są znacznym błędem w stosunku do wartości powodujących zniszczenie betonu. Jednocześnie stwierdzono dobrą dokładność wyznaczenia zmiany długości odcinków pomiarowych, co umożliwia precyzyjne wnioskowanie o zmianach szerokości rozwarcia rys. Wskazano jak szukać szerokości rozwarcia rys, aby osiągnąć zbieżność z wynikami pomiarów prowadzonych tradycyjnie (wzrokowo). Przeprowadzono dyskusję dotyczącą wpływu wielkości podziału powierzchni na otrzymaną szerokość rys.
EN
The aim of the paper is estimating of measuring inaccuracies for Aramis system. Because of issue complexity it is difficult to find general solution. For the application purpose method consists of comparison many photos showing one state of surface is used. In the paper analysis of the inaccuracies for measuring volume 1250 × 1100 mm is presented. Dispersion of the results recorded by Aramis system is the value of the measuring error. It is stated that values from strain maps contain error which is significant with respect to ultimate strain of concrete. Simultaneously very good accuracy of the the line segment length change is reported. It causes that observation of crack width is presisly. In the second part of the paper some practical information concern how determined compatibility between crack width measured traditionally and by Aramis are written. Discussion of influence of facet size on crack width is presented.
PL
Przedstawiono przykład wymiarowania płyt płaskich na przebicie w obrębie połączeń ze słupami narożnymi. Obliczenia przeprowadzono zgodnie z zasadami Model Code 2010, pokazując różnice wyników i konsekwencje wynikające z założenia różnych poziomów dokładności prowadzonej analizy. Uzyskane wyniki skomentowano w świetle rezultatów obliczeń zgodnie z zasadami PN-EN 1992-1-1.
EN
The paper presents the design example how to calculate the flat slab in the connection zones with the corner columns. The analysis was carried out in accordance with the principles of Model Code 2010. The differences between results, which depended on assumed levels of approximations, were shown. The obtained results were commented and compared with the values obtained by calculation conducted in accordance with the principles of Eurocode 2.
PL
Objaśniono zasady wymiarowania płyt płaskich na przebicie w obrębie połączeń ze słupami krawędziowymi. Obliczenia wykonano zgodnie z zasadami Model Code 2010, pokazując zarazem różnice wyników i konsekwencje wynikające z założonych poziomów dokładności prowadzonej analizy. Otrzymane wyniki skomentowano i porównano z uzyskanymi na podstawie obliczeń według PN-EN 1992-1-1.
EN
The paper presents the design example how to calculate the flat slab in the connection zones with edge columns. The analysis was carried out in accordance with the principles of Model Code 2010. The differences between results, which depended on assumed levels of approximations, were also shown. The obtained results were commented and compared with the values obtained by calculation conducted in accordance with the principles of Eurocode 2.
PL
Omówiono badania krótkiego wspornika wzmocnionego konstrukcją stalową, mocowaną do słupa za pomocą kleju i śrub. Wzmocnienie było wykonywane, gdy element pozostawał obciążony. Do momentu przerwania badania, spowodowanego wyczerpaniem możliwości stanowiska badawczego, uzyskano wzmocnienie o ponad 150% w stosunku do modelu świadka.
EN
The results of experimental investigation of the corbel strengthened by the steel accessory fasten by epoxy – adhesive rods to the column are presented in the paper. Strengthening was made when the load was applied. More than 150% increase in load carrying capacity was obtained comparing with non – strengthened model, until the test was stopped, because of ultimate strength of test setup.
13
Content available remote Badania eksperymentalne wzmacniania bardzo krótkich wsporników żelbetowych
PL
W referacie przedstawiono badania doświadczalne dotyczące wzmacniania istniejących krótkich wsporników za pomocą zbrojenia wklejanego. Proporcje wsporników modeli tej serii badawczej charakteryzował stosunek wysięgu do wysokości równy 1:3. Wyniki badań wykazały, że wzmacnianie zbrojeniem wklejanym może okazać się mniej efektywne niż w przypadku wsporników o większym wysięgu. W przypadku wsporników bardzo krótkich o nośności decyduje wytrzymałość betonu. Celem dodatkowego zbrojenia jest przekazanie sił rozciągających, działających poprzecznie do osi ukośnego krzyżulca ściskanego.
EN
The paper presents experimental investigations concerning strengthening of very short corbels by post – installed bars. The slenderness of corbels (ac/h) was equal to 1/3. The results showed that strengthening by the post – installed bars may be less effective than in the case of corbels with greater ac/h ratios. The carrying capacity of very short corbels is determined by concrete strength. The purpose of the additional reinforcement is transferring tensile forces acting laterally to concrete strut.
PL
Przedstawiono przykład ilustrujący sposób wymiarowania płyt płaskich na przebicie w strefie połączeń ze słupami wewnętrznymi. Obliczenia przeprowadzono zgodnie z zasadami Model Code 2010, pokazując różnice w sposobie postępowania w zależności od założonego poziomu dokładności prowadzonej analizy. Otrzymane wyniki skomentowano i porównano z wartościami uzyskanymi na podstawie obliczeń prowadzonych zgodnie z zasadami PN-EN 1992-1-1.
EN
The article presents the design example of dimensioning the flat slab in the connection zones with internal columns. Calculations were carried out in accordance with the principles of Model Code 2010. It was explained the differences in design procedures depending on the assumed level of accuracy of analysis. The results are commented and compared with the values obtained by calculation performed in accordance with the principles of PN-EN 1992-1-1.
15
Content available remote Carrying capacity of axially loaded hsc columns intersected by NSC slab
EN
There are presented and commented in this paper existing code provisions and empirical relationships in a view of results of own experimental investigations. The load transmission mechanism between high strength concrete columns intersected by weaker slab concrete has been considered. Slabs of the specimens were made of normal and lightweight aggregate concrete. One of the examined parameters was an effort grade of the concrete slab in punching shear on the column load carrying capacity. No significant effect of this factor was found. However, considerable effect of concrete type of which slab was made was noted. Even similar concrete strengths of slabs and columns of models, higher load carrying capacity was obtained in case of specimen with normal concrete slab.
PL
W artykule przedstawiono i skomentowano wyniki własnych badań eksperymentalnych w świetle obowiązujących przepisów normowych i formuł empirycznych. Rozważano mechanizm przekazywania oddziaływań pomiędzy słupami z betonu o wysokiej wytrzymałości przewarstwionymi słabszym betonem płyty. Płyty badanych modeli wykonane zostały z betonu zwykłego oraz lekkiego betonu kruszywowego. Jeden z rozpatrywanych parametrów stanowił stopień wytężenia płyty stropowej na przebicie na nośność słupa w obrębie połączenia. Stwierdzono brak istotnego wpływu tego czynnika. Zauważono natomiast wpływ rodzaju betonu płyty na nośność badanych modeli. Mimo zbliżonych wytrzymałości betonów płyt i słupów modeli, większą nośność zarejestrowano w przypadku elementu z płytą z betonu zwykłego.
PL
Podano ogólne zasady projektowania płyt żelbetowych na przebicie według Model Code 2010, stanowiącego propozycję przyszłych przepisów normowych. Omówiono tok postępowania uwzględniający założoną przez projektanta dokładność obliczeń. Pokazano różnice w sposobie określania nośności na przebicie i wymaganego zbrojenia poprzecznego w stosunku do obowiązujących obecnie zasad Eurokodu 2.
EN
The article presents general principles of punching shear dimensioning of reinforced concrete slabs according to Model Code 2010, which is a proposal for future code provisions. Discussed the course of proceedings which takes into account assumed accuracy of the calculations. It has been showed the differences in calculating the punching shear resistance and the required reinforcement compared to current provisions of Eurocode 2.
PL
W pracy zaprezentowano wyniki badań stref podporowych krępych płyt żelbetowych. Badania obejmowały cztery modele w skali 1:2. Wszystkie modele wykonano z tej samej mieszanki betonowej. Również zbrojenie główne było jednakowe we wszystkich modelach. Celem badań było wykazanie wpływu różnie ukształtowanego zbrojenia poprzecznego na nośność płyt na przebicie. Jeden z modeli był bez zbrojenia poprzecznego i służył jako model porównawczy. W pozostałych płytach zastosowano trzy rodzaje zbrojenia na przebicie: klasyczne strzemiona zamknięte obejmujące pręty zbrojenia głównego, strzemiona umieszczone pomiędzy siatkami zbrojenia głównego oraz zbrojenie w postaci drabinek. Wyniki badań wykazały kilkuprocentowe różnice w nośnościach poszczególnych modeli ze zbrojeniem poprzecznym, a najskuteczniejsze okazały się strzemiona klasycznie kształtowane obejmujące pręty zbrojenia głównego.
EN
The results of support zone thick concrete slabs experimental investigation are presented in the paper. The experimental program consisted of 4 square reinforced concrete flat models to 1:2 scale made of the same concrete with the same dimensions and the same flexural reinforcement. The aim of tests was proved the influence of different transverse reinforcement types on punching shear load capacity. One of the models was a comparative slab made without transverse reinforcement. In the other slabs three types of transverse reinforcement were used: typical stirrups enclosing flexure reinforcement, stirrups situated between flexure reinforcement and ladders. The test results show a few percent difference in load capacity between models with transverse reinforcement, the most effective were typical stirrups enclosing the main reinforcement.
PL
W artykule przedstawiono i skomentowano wyniki własnych badań eksperymentalnych dotyczących krawędziowych połączeń płytowo – słupowych. Rozpatrywano mechanizm przekazywania oddziaływań pomiędzy słupami wykonanymi z betonu o wysokiej wytrzymałości a płytą stropową, która wykonana została z betonu zwykłego o wytrzymałości niemal pięciokrotnie niższej. Parametrem zmiennym w prezentowanych badaniach był wysięg wspornikowej części płyty. Stwierdzono istotny wpływ wspornika płytowego o niewielkim nawet wysięgu na wytrzymałość efektywną betonu słupa.
EN
In this paper the results of the experimental investigations of edge column – slab connections are presented and commented on. The load transmission mechanism between high strength concrete columns and slab made of normal, five times lower strength concrete was considered. The variable parameter of presented study was the overhang of slab cantilever. The performed study showed important effect of slab cantilever on effective concrete strength of column in the connection zone.
PL
W referacie omówiono sposoby zbrojenia płyt żelbetowych za pomocą wkładek stalowych umieszczanych pomiędzy siatkami prętów głównych. Takie rozwiązania zapewniają łatwość montażu, ale nie gwarantują skutecznego zakotwienia zbrojenia poprzecznego, które charakteryzuje strzemiona obejmujące zbrojenie podłużne strefy ściskanej i rozciąganej. Nieuzasadnione jest zatem w takich przypadkach stosowanie obliczeniowych procedur normowych. Przedstawiono kilka systemów zbrojenia poprzecznego w formie koszy bądź drabinek. Zaprezentowano dostępne w literaturze wyniki badań eksperymentalnych modeli zbrojonych za pomocą omawianych akcesoriów. Przeprowadzona analiza porównawcza efektywności zbrojenia o niepełnym zakotwieniu wykazała, iż można za jego pomocą znacząco podnieść nośność płyty na przebicie. Otrzymane wartości były jednak na ogół mniejsze od uzyskanych za pomocą procedury normowej – Eurokodu 2.
EN
The paper discusses the issue of load capacity of flat plates with transverse reinforcement situated between the longitudinal reinforcement. Using this types of reinforcement is much more convenient from the installation point of view, however, it does not guarantee complete embedment, as efficient as traditional stirrups that comprise longitudinal reinforcement in compression and the tension zone. The transverse rods do not comprise the main reinforcement, so their slide out of the concrete slabs or cracks parallel to the plane of the longitudinal reinforcement and delamination of the slab can occur. The different types of transverse reinforcement were presented: system consisting of ready-made bolts, reinforcement baskets or ladders. Experimental results of plates with these types of reinforcement are presented. The analysis of effectiveness of reinforcement anchorage indicates that transverse bolts can be used to increase the punching shear load capacity of the plates. The resulting capacity was only of about 20% lower than result elements with complete embedment. Experimental results were similar to the theoretical capacity resulting from the consideration by Eurocode 2.
PL
W artykule przedstawiono problem nośności słupów wykonanych z betonu wysokiej wytrzymałości przedzielonych żelbetową płytą wykonaną z betonu lekkiego. Zaprezentowano wyniki własnych badań eksperymentalnych trzech modeli reprezentujących połączenie słupa wewnętrznego z płaską płytą żelbetową wykonaną z betonu lekkiego o trzykrotnie mniejszej wytrzymałości od betonu słupa. Parametrem zmiennym relacjonowanych była wielkość obciążenia płyty. Wykonane badania wykazały brak wpływu tego parametru na wytrzymałość efektywną betonu słupa.
EN
This paper presents the problem of load carrying capacity of the columns made of high-strength reinforced concrete which are separated by slab made of lightweight concrete. The experimental investigations of three models representing the internal connection between column and flat slab made of lightweight concrete of the strength tree times less than concrete strength of column are presented. The effort degree on the punching shear capacity stands for the variable parameter in the presented study. The performed study shows that there is no effect of this parameter on the effective concrete strength of the column.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.