The aim of this study was to determine the influence of long-term exposure of Ringer’s solution on degradation of the anodically oxidated Ti6Al4V alloy coated with a biodegradable polymer coating. Polymeric coatings made of poly(glycolide-ε-caprolactone) – G-Cap and poly(glycolide- ε-caprolactone-lactide) – G-Cap-L were applied by a dip-coating method. Degradation was assessed on the basis of the results of pitting corrosion resistance and density of metal ions infiltrating to the solution. Studies were conducted for samples after 3, 6, 8, 10 and 12 weeks of exposure to the corrosive environment. In addition, topography of the surface of the polymer coating was assessed. As a result of potentiodynamic studies, the value of the polarization resistance and corrosion potential for the G-Cap and G-Cap-L coated samples were significantly decreased while simultaneous reduction of the density of metal ions infiltrating to the solution throughout the whole study period. There was also observed a faster degradation of the G-Cap coating compared to G-Cap-L, which showed local discontinuity after 12 weeks of exposure. The obtained results provide the basis for the development of polymeric coatings on surface of metal implants with predictable time / kinetics of degradation by selecting the composition of polymers while simultaneous limitation of metal ions infiltration into surrounding tissues.
PL
Celem pracy było określenie wpływu długotrwałego oddziaływania rozworu Ringera na proces degradacji utlenianego anodowo stopu Ti6Al4V pokrytego powłoką biodegradowalnego polimeru. Powłoki polimerowe wykonane z poli(glikolido- ε-kaprolaktonu) – G-Cap oraz poli(glikolido ε-kaprolaktono- laktydu) – G-Cap-L naniesiono metodą zanurzeniową (dip-coating). Proces degradacji w funkcji czasu oceniano na podstawie wyników badań odporności na korozję wżerową oraz gęstości masy jonów metalowych przenikających do roztworu. Badania przeprowadzono dla próbek po 3, 6, 8, 10 i 12 tygodniach ekspozycji na środowisko korozyjne. Ponadto oceniano topografię powierzchni powłoki polimerowej. W wyniku przeprowadzonych badań potencjodynamicznych stwierdzono wyraźne obniżenie wartości oporu polaryzacyjnego i potencjału korozyjnego dla próbek z naniesionymi powłokami G-Cap i G-Cap-L przy jednoczesnym wyraźnym ograniczeniu gęstości jonów metalowych przenikających do roztworu w całym okresie badawczym. Stwierdzono również szybszą degradację powłoki typu G-Cap w porównaniu do G-Cap-L, dla której po 12 tygodniu ekspozycji stwierdzono lokalnie występujące przerwania ciągłości. Uzyskane wyniki dają podstawę do opracowywania na powierzchni implantów metalowych powłok polimerowych o przewidywalnym czasie/określonej kinetyce degradacji, poprzez dobór składu polimerów z jednoczesnym ograniczeniem możliwości przenikania jonów metalowych do otaczających tkanek.
4
Content available Corrosion resistance of PLGA-coated biomaterials
EN
The aim of the study was to determine the influence of PLGA bioresorbable polymer coating on corrosion resistance of metal biomaterial. Polymer coating deposited by immersion method was applied. Corrosion resistance of metal biomaterials (stainless steel, Ti6Al4V, Ti6Al7Nb) coated with PLGA polymer, after 90 days exposure to Ringer’s solution was tested. The amount of metal ions released to the solution was also investigated (inductively coupled plasma–atomic emission spectrometry (ICP-AES) method). The surface of the samples was observed using atomic force microscopy (AFM) and scanning electron microscopy (SEM). Degradation of PLGA was monitored with the use of the 1 H NMR spectroscopy and GPC (Gel Permeation Chromatography). The studies were carried out for non-sterilized (NS) and sterilized (S) samples. Application of the polymer coating causes a reduction of release of metal ions to the solution. Depending on metal substrate different course of destruction of polymer layer was observed. After 90 days of incubation in Ringer’s solution polymer layer was highly degraded, however, the composition of copolymer (ratio of the comonomeric units in the chain) remained unchanged during the whole process, which suggests even degradation. The polymer layer reduced degradation kinetics of the metal substrate. Moreover, degradation process did not change surface morphology of metal substrate and did not disturb its integrity. The results obtained indicate that the applied polymer layer improves corrosion resistance of the alloys being investigated. Thus, the developed implants with bioresorbable coatings could be advantageous for medical applications.
EN
Determining thermal properties and morphology seems to be useful in the analysis of release and degradation processes form polymeric materials. Risperidone is available in the formulation of a long-acting injection based on poly(D,L-lactide-co-glycolide). Currently, alternative solutions are also offered, i.e., nano- and microparticles or implants, including copolymers of lactide and glycolide. The effect of risperidone content on the properties of poly(L-lactide-co-glycolide) matrices was determined. The study also involved an assessment of the changes during degradation. Risperidone free matrices and the matrices with risperidone were obtained by solvent casting. Thermal characteristics were tested by means of differential scanning calorimetry, and the morphology was evaluated using a scanning electron microscope. Risperidone did not change significantly semi-crystalline structure of poly(L-lactide-co-glycolide) matrices. The decrease in crystallization temperature and glass transition temperature during degradation was observed. Many pores and their deformation, the widening of pore area, cracks and slits because of degradation were observed. The analysis of thermal properties and morphology allowed us to explain degradation process. Matrices exhibited stable process of degradation, which may be advantageous for development of prolonged risperidone release systems.
EN
A crucial factor in the design of safe and effective drug delivery systems is the development of biocompatible carriers, which offer the possibility to tailor the drug release kinetics for specific drugs. The determination of the factors controlling drug release, as well as the methods to adjust the properties of the polymer, is necessary. The influence of the copolymer chain microstructure on degradation, and thus the drug release profile, has been demonstrated; therefore, this factor cannot be neglected during the development of controlled drug delivery systems.
PL
Artykuł stanowi przegląd literatury dotyczący projektowania systemów kontrolowanego uwalniania leków, opartych na poliestrach lub poliestrowęglanach. Omówiono znaczenie rodzaju i właściwości opracowywanych do tego celu biokompatybilnych nośników, umożliwiających dopasowanie kinetyki uwalniania do określonego leku. Wskazano czynniki wpływające na szybkość uwalniania leków związane ze środowiskiem, postacią leku, rodzajem i właściwościami polimeru użytego w charakterze nośnika, a także z mikrostrukturą łańcuchów polimerowych.
EN
Compared with injectable drug delivery systems (DDS), pharmaceutical implants can provide prolonged drug release, delivery of a higher amount of bioactive agent into the site of action and a higher local drug concentration. Simultaneously, these implants are simple to process and provide a reduction in drug toxicity that is typical for systemic administration. This article presents the composition, application and methods of processing of the implantable drug delivery systems that have already entered the market.
PL
W porównaniu z systemami kontrolowanego uwalniania leku przeznaczonymi do iniekcji, implanty zapewniają wydłużony czas uwalniania leku, możliwość dostarczenia większej ilości leku do miejsca działania, wyższe miejscowe stężenie leku oraz ograniczenie, typowej dla podania systemowego, toksyczności leku. Zaletą jest także mało skomplikowany proces otrzymywania implantów polimerowych do zastosowań farmaceutycznych. W publikacji przedstawiono obecne na rynku implantowane systemy transportu leku, ich skład, zastosowanie oraz metody otrzymywania.
PL
W niniejszej pracy była opracowywana implantacyjna postać leku zawierająca rysperydon wytworzona z poli(L-laktydo-ko-glikolidu) (L-PLGA) oraz poli(D,L- laktydo-ko-glikolidu) (D,L-PLGA) zastosowanych jako nośniki leku. Ustalano wpływ właściwości powierzchniowych i strukturalnych na początkowe uwalnianie rysperydonu podczas pierwszych 24 godzin inkubacji. W tym celu zastosowano wysokosprawną chromatografię cieczową, spektroskopię magnetycznego rezonansu jądrowego, skaningową kalorymetrię różnicową, skaningowy mikroskop elektronowy oraz mikroskop sił atomowych. We wszystkich analizowanych danych zaobserwowano różnice pomiędzy matrycami wykonanymi z L-PLGA, a matrycami sporządzonymi z D,L-PLGA. Nie wykazano efektu wyrzutu dla żadnego z badanych polimerów, jakkolwiek ilość uwolnionego leku w przypadku matryc D,L-PLGA była prawie pięciokrotnie wyższa. Kopolimer L-PLGA charakteryzował się znacząco większą średnią długością blokówlaktydylowych iglikolidylowych niż D,L-PLGA. Co więcej, zaobserwowano inny charakter powierzchni analizowanych matryc, to znaczy w przypadku L-PLGA powierzchnia była porowata, podczas gdy w przypadku D,L-laktydu nie obserwowano perforacji. Niewątpliwie istnieje zależność między początkowym uwalnianiem rysperydonu, a topografią i strukturą matryc polimerowych. Przypuszcza się, że większe uwalnianie leku z L-PLGA było bardziej związane z właściwościami powierzchniowymi niż ze strukturą matryc. Otrzymane wyniki wskazują na ogromny potencjał obu tych polimerów i możliwość wybrania optymalnego materiału.
EN
In this work, implantable drug formulation with risperidone on the basis of poly(L-lactide-co-glyco- lide) (L-PLGA) and poly(D,L-lactide-co-glycolide) (D,L-PLGA) as drug carries has been developed. The influence of surface and structural properties on the initial release of risperidone during the first 24 hours has been determined. In this aim, high-performance liquid chromatography, nuclear magnetic resonance spectroscopy, differential scanning calorimetry, scanning electron microscope and atomic force mic¬roscope were used. The differences between L-PLGA and D,L-PLGA matrices in all analyzed data were noted. The burst effect was not revealed for any of the studied polymers, however the released drug was almost five times larger for D,L-PLGA matrices. The L-PLGA copolymer revealed a significantly longer average length of the lactidyl and glycolidyl blocks than D,L-PLGA. Moreover, various characters of surface for analyzed matrices were shown, i.e. in the case of L-PLGA the surface was porous and in the case of D,L-PLGA it was nonporous. Undoubtedly, there were dependences between risperidone's initial release and the topography and the structure of polymeric matrices. We suppose that the larger drug release for L-PLGA was more associated with surface properties than with structure of matrices. The obtained results show the great potential of both polymers and possibility to choose the optimal material.
EN
In this work, implantable drug formulation with risperidone on the basis of poly(L-lactide-co-glycolide) (L-PLGA) and poly(D,L-lactide-co-glycolide) (D,L-PLGA) as drug carries was developed. The influence of surface and structural properties on the initial release of risperidone during the first twenty four hours was determined. In this aim, high-performance liquid chromatography, nuclear magnetic resonance spectroscopy, scanning electron microscope and atomic force microscope were used. Significant differences between L-PLGA and D,L-PLGA matrices in all analyzed data were noted. The burst effect was not revealed for any of the studied polymers, however the released drug was almost five times larger for D,L-PLGA matrices. The L-PLGA copolymer revealed a significantly longer average length of the lactidyl and glycolidyl blocks than D,L-PLGA. Moreover, various characters of surface for analyzed matrices were shown, i.e. in case of L-PLGA the surface was porous and in case of D,L-PLGA it was nonporous. Undoubtedly, there were dependences between risperidone's initial release and the topography and the structure of polymeric matrices. We suppose that the larger drug release for L-PLGA was more associated with surface properties and thus structure of matrices. The obtained results showed the great potential of both polymers and possibility to choose the optimal polymer.
EN
Biomedical application of biodegradable shape memory terpolymers obtained from L-lactide, glycolide, trimethylene carbonate (TMC) have been intensively investigated in recent years. All applicable biomedical materials must be biocompatible, which means that they cannot cause toxic, cytotoxic, allergic, or carcinogenic reactions. The first study evaluating the biocompatibility of the material is determination of its cytotoxicity. The purpose of this study was to assess the biocompatibility of poly(L-lactide-co-glycolide-co-trimethylene-carbonate) 75:13:12, synthesized using Zr(Acac)4 as an initiator of polymerization. The terpolymer was degraded for 30, 60 and 90 days at 37§C in water. The effect of degradation products on the growth of human articular chondrocytes was determined using the sulforhodamine B assay. The examined terpolymer was characterized by means of NMR spectroscopy, GPC and DSC. The results showed that the studied terpolymer was biocompatible with tested cells.
EN
Chemically modified nucleotides, which are not normally present in genetic material, are called DN A adducts. This type of DN A modifications (damage) is directly related to processes of mutagenesis and carcinogenesis. Elevated levels of DN A adducts present in genetic material reflect exposure of humans to carcinogenic factors and are markers of increased risk of cancer [1]. For this reason different methods useful for quantitative and qualitative analyses of DN A adducts are used in the field of cancer prevention and research (Tab. 1). Enzymatically-catalyzed methylation of cytosine, observed mostly in so called CpG islands, is a frequent endogenous modification of genetic material. Such a DN A methylation is a key factor involved in regulation of gene expression, and methylation status of oncogenes and tumor supressor genes is an important biomarker of carcinogenesis. As such, analytical methods for assessment of DN A methylation are of great importance for molecular diagnostics of cancer. During the last decade significant progress has been made in methods available for quantitative, qualitative and structural analyses of biological molecules. Among intensively developed tools for bioanalyses are methods of mass spectrometry. Spectrometers that are based on two methods of ionization, namely electrospray ionization (ESI ) [30] and matrix-assisted laser desorption-ionization (MALDI ) [48], are particularly suitable for analyses of biological macromolecules: proteins and nucleic acids. Currently available mass spectrometers, together with microscale methods for sample preparation and separation, significantly increased sensitivity and accessible mass range of analyses. New generation of “user-friendly” instruments is developed to bring the techniques directly into the workplaces of biological and clinical investigators. This review demonstrates representative examples of mass spectrometry techniques used for qualitative analyses of nucleotide modifications and adducts present in genetic material of humans. In this field several methods base on spectrometers with electrospray ionization. Generated ions are separated according to their mass-to-charge ratio in an analyzer by electric fields; among different ion analyzers frequently used in this methods are single or triple quadrupole and ion traps (Fig. 1). Among other methods available for assessment of DN A adducts is so called Accelerator Mass Spectrometry (Fig. 2) [41]. The most frequently applied method for the assessment of DN A methylation is based on methylation-specific PCR reaction. Products of such PCR reactions are analyzed using MALDI mass spectrometry [54] (Fig. 3). In summary, new powerful methods of mass spectrometry that made available qualitative analyses of damage and modifications of human genetic material found their important place in modern biological and medical laboratories.
PL
Tkanka chrzęstna charakteryzuje się małą zdolnością regeneracji oraz niewielkim potencjałem do prawidłowej odbudowy, dlatego też, dotychczas stosowane metody leczenia uszkodzeń chrząstki są niewystarczające. Nadzieję na przełom w leczeniu wielu chorób chrząstki, jak również regenerację tej tkanki, daje inżynieria tkankowa wykorzystująca m.in. syntetyczne polimery z grupy poliestrów alifatycznych i poliwęglanów takie jak kopoolimery glikolidu, ε-kaprolaktonu, L-laktydu oraz trimetylenowęglanu zsyntetyzowane za pomocą nowatorskiej metody wykorzystującej jako inicjator polimeryzacji acetyloctan cyrkonu. W ramach niniejszej pracy dokonano oceny biozgodności wybranych biodegradowalnych materiałów w oparciu o poziom sekrecji prozapalnych cytokin IL-1α i IL-1β, IL-6 oraz IL-8 oznaczonych metodą ELISA. Spośród badanych polimerów biodegradowalnych pod-łoża o składzie PCLGA 92:8, PLAGA 85:15, PLATMC 70:30, PLATMC 30:70, PLATMC 50:50 wydają się charakteryzować największą biozgodnością, gdyż ich obecność nie powodowała istotnego wzrostu sekrecji cytokin prozapalnych przez chondrocyty rosnące na ich powierzchni. Pozostałe badane materiały polimerowe powodowały pewne niepożądane reakcje komórek związane ze stymulacją uwalniania niektórych spośród analizowanych cytokin prozapalnych przez chondrocyty. Uzyskane wyniki pozwoliły na wyciągnięcie wniosku, iż podłoża wykonane z analizowanych w pracy polimerów biodegradowalnych zsyntetyzowanych przy użyciu acetyloacetonianu cyrkonu zasługują na dalszą uwagę, gdyż niosą nadzieję na umożliwienie leczenia ubytków tkanki chrzęstnej.
EN
Cartilage characterizes low potential to regeneration and proper reconstruction. Nowadays, methods of cartilage lesions treatment are unsatisfactory. Tissue engineering is very promising in therapy of many cartilage injures as well as regeneration of this tissue. Biodegradable aliphatic polyesters and polyesterocarbonates such as copolymers of glycolide, L-lactide, ε-caprolactone and trimethylene carbonate were synthesized using a novel method employing non-toxic zirconium acetylacetonate as initiator of polymerization. The aim of the study was to examine biocompatibility of selected biodegradable materials based on the level of secretion of proinflammatory cytokines IL-1α, IL-1β, IL-6 and IL-8. Our results show, that among the studied biodegradable polymers the PCLGA 92:8, 85:15 PLAGA, PLATMC 70:30, PLATMC 30:70, 50:50 PLATMC were characterized by highest biocompatiblity, because they do not cause a significant increase in secretion of proinflammatory cytokines by chondrocytes growing on their surface. Other polymers could cause up-regulation of some proinflammatory cytokines secretion by chondrocytes cultured on their surface. The other tested polymeric materials did not induce the release of proinflammatory cytokines by chondrocytes. Generally, it should be concluded that the studied biodegradable copolymers synthesized with the use of zirconium acetylacetonate as initiator of polymerization deserve further attention, as being promising for the treatment of cartilage defects.
PL
W pracy przedstawiono wyniki badań wpływu formowania implantów polimerowych metodą wtrysku oraz ich sterylizacji wiązką elektronów na zmiany struktury i właściwości termicznych trzech różnych terpolimerów LL-laktydu, glikolidu i węglanu trimetylenu z pamięcią kształtu. Polimery charakteryzowano wykorzystując analizę DSC (właściwości termiczne), GPC (masy cząsteczkowe) i 1H NMR (skład i mikrostruktura). Badano materiał wyjściowy po syntezie, uformowane metodą wtrysku matryce polimerowe, sterylne matryce polimerowe i materiał sterylny nie przetworzony. Oceniono przydatność wybranych metod przetwarzania do zastosowania w produkcji biozgodnych implantów polimerowych. Zauważono wpływ stosowanych metod przetwórstwa na badane własności polimerów.
EN
In the present work the result of obtaining implants by injection moulding method and their high energy electron beam sterilization was presented. Changes of microstructure and thermal properties were observed. Three different terpolymers were characterized by using DSC, GPC and 1H NMR method. Raw material and polymer matrices before and after sterilization were examined. Application of this processing method for production of biocompatible and biodegradable shape memory polymer matrices production was estimated. An impact of applied method on tested polymer property was noticed.
PL
Sterylizacja jest bardzo ważnym czynnikiem uzależniającym przydatność materiałów do zastosowań medycznych. Obiecującą metodą sterylizacji wydaje się być promieniowanie wiązką elektronową. Celem badania była analiza wpływu promieniowania elektro-nowego (EB) na terpolimery zawierające paklitaksel. Dwa typy materiałów użyto do przygotowania matryc zawierających 5 i 10% leku, jak również matryc bez leku: poli(L-laktyd-ko-glikolid-ko-ε-kaprolakton) (44:32:24) – P(LA:GA:Cap) oraz poli(L-laktyd-ko-gli-kolid-ko-węglan trimetylenu) (62:27:11) – P(LA:GA:TMC). Wszystkie otrzymane matryce badano przed i po procesie elektronowego napromieniania dawką 25kGy za pomocą spektroskopii NMR, DSC i GPC. Nie wykazano różnic w składzie komonomerów, temperaturze zeszklenia, liczbowo średniej masie cząsteczkowej jak również w rozrzucie mas cząsteczkowych (dyspersyjność) pomiędzy matrycami otrzymanymi z tego samego typu terpolimeru przed procesem sterylizacji. Promieniowanie elektronowe spowodowało spadek liczbowo średniej masy cząsteczkowej oraz temperatury zeszklenia. Zmiany w składzie komonomerów zauważono tylko w przypadku matryc z P(LA:GA:Cap), co może sugerować mniejszą odporność jednostek kaproilowych na sterylizację.
EN
Sterilization is a very important factor determining usefulness of materials for medical application. The promising method of sterilization seems to be electron beam radiation. The aim of this study was to analyze the influence of the EB radiation on terpolymers containing paclitaxel. Two types of materials were used to prepare three kinds of matrices – with 5% and 10% of paclitaxel as well as drug free matrices. The selected terpolymers were: poly(L-lactide-co-glycolide-co-ε-caprolactone) (44:32:24) – P(LA:GA:Cap) and poly(L-lactide-co-glycolide-co-trimethylene carbon-ate) (62:27:11) – P(LA:GA:TMC). All of the obtained matrices were investigated before and after electron beam (EB) irradiation with the dose of 25 kGy with the use of 1H NMR spectroscopy, DSC and GPC. There were no differences in comonomer molar ratio, glass transition temperature, the number average molecular weight and dispersity index between non-irradiated matrices prepared from the same terpolymer type, regardless paclitaxel content. EB radiation caused decrease of the number average molecular weight as well as the glass-transition temperature. The changes of comonomer units’ ratio were noticed only in the case of P(LA:GA:Cap) matrices that may suggest lower susceptibility to sterilization of caproyl units.
PL
W celu optymalizacji leczenia schizofrenii proponowanych jest wiele rozwiązań. Do jednego z nich należy zastosowanie biodegradowalnych, implantowanych systemów uwalniających leki. W niniejszej pracy badano za pomocą mikroskopii sił atomowych zmiany powierzchni matryc otrzymanych z poli(L-laktydo-koglikolidu) (PLAGA) i rysperydonu przed i po dwóch tygodniach degradacji. Analizowano także wpływ degradacji na zmiany ubytku masy matryc polimerowych. Wyniki wskazują na duże możliwości matryc PLAGA do inkorporowania i pułapkowania rysperydonu. Po dwóch tygodniach stwierdzono stabilność matryc (nie uległy one gwałtownej i niekontrolowanej degradacji). Matryce otrzymane z PLAGA posiadają właściwości powierzchniowe odpowiednie dla zastosowania jako biodegradowalne systemy o kontrolowanym uwalnianiu rysperydonu.
EN
Various solutions are proposed to optimize the therapy of schizophrenia. One of them is the application of biodegradable implantable drug delivery systems. In this work, surface changes of matrices composed of poly(L-lactide-co-glycolide) (PLAGA) and risperidone before and after two weeks of degradation were determined by atomic force microscopy. The influence of degradation on weight loss of matrices was also observed. The results suggest that PLAGA matrices present great potential for incorporation and trapping of risperidone. After two weeks of the studies, the matrices were stable and were not subjected to rapid and uncontrolled degradation. PLAGA matrices have surface properties useful for designing of biodegradable system of controlled risperidone release.
PL
W niniejszej pracy analizowano wpływ substancji wymywalnych, otrzymanych w drodze ekstrakcji z bioresorbowalnych terpolimerów zsyntetyzowanych przy użyciu Zr(Acac)4 i przetwarzanych metodą prasowania, na wzrost chondrocytów ludzkich w warunkach in vitro. Matryce wykonane z poli(L-laktydo- ko-glikolido-ko-węglanu trimetylenu) 75:14:11 oraz poli(L-laktydo-ko-glikolido-ko-ε-kaprolaktonu) 55:29:16 charakteryzowano za pomocą spektroskopii NMR, GPC oraz DSC. Ekstrakcję przeprowadzono w medium hodowlanym z matryc polimerowych przed degradacją oraz po 30, 60 i 90 dniach degradacji. Nie stwierdzono zahamowania wzrostu chondrocytów inkubowanych w obecności ekstraktów uzyskanych z matryc P(L-LA-GA-TMC) 75:14:11 w porównaniu z kontrolą (medium hodowlane) oraz UHMWP, niezależnie od zastosowanego rozcieńczenia i stopnia zdegradowania matryc. Zaobserwowano natomiast zahamowanie wzrostu chondrocytów inkubowanych w obecności rozcieńczonych pożywką ekstraktów (1:4), otrzymanych z matryc P(L-LA-GA-CL) 55:29:16, poddanych 60- i 90-dniowej degradacji.
EN
The influence of substances extracted from bioresorbable terpolymers, synthesized with Zr(Acac)4 as initiator and processed by compression, on human chondrocytes growth in vitro, was analyzed in this study. The matrices obtained from poly (L-lactideco- glycolide-co- trimethylene-carbonate) 75:14:11 and poly (L-lactide-co-glycolide-co-ε-caprolactone) 55:29:16 were characterized by means of NMR spectroscopy, GPC and DSC. Extracts were prepared of polymeric matrices before and after 30, 60 and 90 days of degradation in chondrocytes growth medium. The obtained results did not show growth inhibition of chondrocytes incubated with extracts of P(LA-GATMC) 75:14:11, compared to growth medium (control) and UHMWP (negative control), regardless the used dilution and degree of matrices’ degradation. Growth inhibition was observed in the case of chondrocytes incubated with extracts of P(LA-GA-CL) 55:29:16 matrices after 60 and 90 days of degradation diluted with medium to 1:4.