This paper presents an analysis of the introduction of power quality assessment through power quality indexes within the framework of an agent-based power system control. The objective is to account for power quality in the power management of systems where the total power of the loads significantly exceeds the power available from generation. This is typically the case of next generation all-electric warships.
The paper presents an implementation of a virtual instrument to perform wavelet analysis on the Park Power components. The main purpose of the analysis is an automatic detection of load in a power system applying load signature analysis. A justification for the approach is presented, followed by the details about the specific implementation performed in the laboratory. Finally a preliminary testing activity based on the use of Hardware in the Loop approach is also presented.