The basic materials strategies to overcome the barriers for transferring enzyme based electrochemical biosensors to practical realisation are reviewed in the paper, The work has centred on a glucose sensor. Properties of several materials used for immobilisation of bioreagent (enzymes) are considered, These properties refer to stability, selectivity, dynamics etc. of the biolayer. The role of porous membranes to reduce the open sensor aperture which remains open for O(2) are discussed. Membrane lamination for providing a barrier and specialist function means are considered. Biocompatibility problems of biosensor are presented. Open microflow pumpless technique as method for intra tissue glucose monitoring is discussed. Utilisation of interdigitated Au electrodes for detection of DNA hybridisation was mentioned.
PL
W artykule dokonano przeglądu podstawowych strategii materiałowych mających na celu pokonanie przeszkody na drodze prowadzącej do praktycznego zastosowania bioczujników enzymatycznych. Praca koncentruje sią na czujnikach glukozy. Rozpatrzono właściwości kilku materiałów wykorzystywanych do immobilizacji bioreagentów (enzymów). Właściwości te odnoszą się do stabilności, selektywności, dynamiki itd. warstwy enzymatycznej. Dyskutowana jest rola membrany porowatej, służącej do zredukowania apertury czujnika, która pozostaje otwarta dla O(2). Rozważono celowość wykonania membrany laminowanej, zapewniającej spełnienie funkcji blokującej i pomiarowej. Przedstawiono problemy biozgodności bioczujników. Wskazano na możliwość zastosowania bezpompowej techniki otrzymywania otwartych mikro-przepływów, w celu monitorowania glukozy wewnątrztkankowej.
2
Content available remote Glucose monitoring, dynamics and feedback control
EN
Normal physiological changes in glucose exhibit both ultradian and diurnal variation with superimposed low amplitude biphasic cyclic fluctuation. Attempts to mimie the natural pancreatic response by use of integrated artificial biofeedback systems have presented a complex problem. Although several complete and partial control models have been developed for predictive therapy regimens, these are most suited to advisory roles and would prove inadequate and possibly dangerous if relied up on implicitly. Over the past decade many researchers have driven forward the development of real-time monitoring sensors deviees but in the majority of cases excessive time delays resultant from sampling delays or restrictive implant sites have compromised the efficiency of feedback performance. Ideally the use of non-invasive technology as provided by infrared based deviees holds most promise for continuous, painless monitoring but the technology is still in its infancy. More secure for current use are enzyme based biosensors, notably a recently modified implantation strategy, incorporating fluid microflow into tissue.
PL
Stężenie glukozy we krwi wykazuje fizjologiczne wahania, podlegając nakładającym się niskoamplitudowym dwufazowym fluktuacjom w cyklach 24-godzinnym i krótszych. Próba naśladowania naturalnej odpowiedzi trzustki na stężenie glukozy za pomocą złożonych, opartych na biologicznym sprzężeniu zwrotnym, sztucznych systemach, okazała się skomplikowanym zagadnieniem. Chociaż opracowano kilkanaście pełnych i częściowych modeli przeznaczonych do przewidywania wyników terapii, to, są one raczej dostosowane do pełnienia funkcji doradczych. Bezpośrednie oparcie się na nich w leczeniu byłoby nieodpowiednie i potencjalnie niebezpieczne. W ciągu ostatniego dziesięciolecia wielu badaczy podejmowało próby opracowania czujników monitorujących stężenie glukozy w czasie rzeczywistym, ale w większości przypadków nadmierne opóźnienia wynikające z opóźnień próbkowania lub ograniczeń związanych z miejscem wszczepienia, zmniejszały efektywność realizacji pomiaru zamykającego pętlę sprzężenia zwrotnego, Zastosowanie technologii nieinwazyjnej, oferowanej przez urządzenia wykorzystujące promieniowanie podczerwone, jest najbardziej obiecujące dla realizacji ciągłego, bezbolesnego pomiaru stężenia glukozy, ale technologia ta jest wciąż w stadium początkowym. Obecnie pewniejsze są bioczujniki enzymatyczne, zwłaszcza po ostatnich modyfikacjach strategii implantacji, polegających na wprowadzeniu mikro przepływu dotkankowego.