Aim: The aim of this article is to make an overview of selected features of the voice alarm control and indicating equipment (VACIE) confirmed in the process of assessment and verification of constancy of performance. Information presented by the authors play a crucial role during the process of design and use of voice alarm systems as well as in the context of providing the safety of buildings. Introduction: Control and indicating equipment (CIE) is extremely important for the safety of buildings, affecting both the safety of the occupants and the property stored there. Given such an important role, special emphasis is placed on the reliability of the system’s operation, whose task is both to detect the fire danger early enough but also to transmit information to its various components. An important role in ensuring the safety of construction objects is the transmission of information about the threat detected by the system to the occupants of the facility. This information can be communicated through the use of, among other things, automatic visual signalling implemented by VAS. The main component of VAS is the voice alarm control and indicating equipment, which, as the heart of the system, receives and transmits information to individual elements (loudspeakers), and is responsible for their operation – powering and monitoring them. Methodology: An overview of selected features that are confirmed in the process of assessment and verification of constancy of performance, Introduction to the testing process of selected features, which is an integral part of the conformity assessment of construction products. The article was supplemented with issues related to the design and maintenance of fire alarm systems. Conclusion: Voice alarm control and indicating equipment, in addition to control and indicating equipment, not only determine the safety of the buildings themselves, but also affect the safety of their occupants, who, as a result of various circumstances, may have to be forced to quickly and efficiently leave their place of residence. Nevertheless, the awareness of owners and managers of construction objects equipped with VAS should be important, since their special attention should be directed to maintaining all components of the system in such a condition that will enable the complete installation to fulfil its functions. An important element is the continuous education of service personnel and users of the facility (e.g. step-by-step evacuation drills), in order to maintain knowledge at the highest possible level about how to act in an emergency situation, not only related to fire, but also in the face of other local threats.
PL
Cel: Celem pracy jest przegląd wybranych cech central dźwiękowych systemów ostrzegawczych (DSO), które potwierdzane są w procesie oceny i weryfikacji stałości właściwości użytkowych. Zaprezentowane przez autorów informacje odgrywają istotną rolę w procesach projektowania i eksploatacji dźwiękowych systemów ostrzegawczych oraz zapewnianiu bezpieczeństwa w obiektach budowlanych. Wprowadzenie: Systemy sygnalizacji pożarowej mają niezwykle istotne znaczenie dla bezpieczeństwa obiektów budowlanych. Wywierają wpływ na bezpieczeństwo zarówno przebywających tam osób, jak i przechowywanego tam mienia. Z uwagi na powyższe szczególny nacisk kładzie się na niezawodność pracy systemu, którego zadaniem jest nie tylko odpowiednio wczesne wykrycie zagrożenia pożarowego, ale również przekazanie informacji do poszczególnych jego elementów. Ważną rolę w zapewnieniu bezpieczeństwa obiektów budowlanych ma przekazanie informacji o wykrytym przez system zagrożeniu do osób przebywających w obiekcie. Alarmowanie może być realizowane m.in. poprzez automatyczną sygnalizację akustyczną DSO. Głównym elementem DSO jest centrala, która stanowi serce systemu – odbiera i przekazuje informacje do poszczególnych elementów wykonawczych (głośników) oraz odpowiada za ich pracę – zasila je i monitoruje. Metodologia: Przegląd wybranych cech potwierdzanych w procesie oceny i weryfikacji stałości właściwości użytkowych. Przedstawienie procesu badawczego wybranych parametrów – nieodłącznego elementu oceny zgodności wyrobów budowlanych. Artykuł wzbogacono o zagadnienia związane z projektowaniem i konserwacją systemów sygnalizacji pożarowej. Wnioski: Centrale DSO – obok central sygnalizacji pożarowej – stanowią nie tylko o bezpieczeństwie samych obiektów budowlanych, ale również o bezpieczeństwie ich użytkowników, którzy na skutek różnych okoliczności mogą być zmuszeni do jak najszybszego, sprawnego opuszczenia miejsca swojego pobytu. Nie mniej istotna jest świadomość właścicieli i zarządców obiektów budowlanych wyposażonych w DSO. Ich szczególna uwaga powinna być skierowana na utrzymanie wszystkich podzespołów systemu w stanie, który będzie umożliwiał spełnienie przez kompletną instalację swoich funkcji. Ważnym elementem jest ciągła edukacja personelu obsługi oraz użytkowników obiektu (np. ćwiczenia stopniowej ewakuacji), aby na jak najwyższym poziomie utrzymywać wiedzę o sposobach postępowania w sytuacji zagrożenia, nie tylko związanego z pożarem, ale również wobec innych miejscowych zagrożeń.
Purpose: The aim of this publication is to present the most important aspects of using smoke and carbon monoxide detectors intended for households or similar residential facilities as well as to indicate the advantages and disadvantages of the adopted system solutions that affect the number of detectors installed in this kind of buildings. The article aims to present the issues related to the Integrated Qualifications System (ZSK), i.e. newly developed market qualification, dedicated to installers and maintenance technicians of smoke and carbon monoxide detectors. Introduction: Smoke and carbon monoxide detectors for early detection of existing threats such as fires or escaping carbon monoxide are an important element of fire protection, dedicated primarily to owners of residential buildings. In many countries in the EU it is obligatory to install detectors in homes, whereas at the moment in Poland the only aspect regulated legally is the obligation of the manufacturer of these products to obtain a certificate. Since 2016, the ZSK has been operating in Poland, in which in 2019 the qualifications of installers/maintenance technicians of smoke and carbon monoxide detectors were distinguished. As a result, a person with a market qualification certificate is prepared for independent installation and maintenance of fire safety monitoring devices Methodology: As part of the research process, theoretical research was used, such as: analysis of literature and legal documents, synthesis, generalization, inference, comparison and analogy. As part of the research, documents from such countries as Poland, Great Britain (mainly England), Germany and France were analysed. The selection of individual countries was guided by the level of development of these systems in a given country and the availability of source documents Conclusions: The presented analysis of the requirements for the installation of the smoke and carbon monoxide detectors shows how different the approach is regarding the use of this type of devices. Depending on experiences and the administrative structure of a given country, a variety of regulations, whether legal or normative, can be discerned in the use of smoke and carbon monoxide detectors. ZSK is a well-described system of formal organization and classification of competences and offers the public services at the highest possible quality level. It is also a partial solution to the problem of installing detectors. However, it is necessary to regulate this issue from the legal level, as it was the case in other EU countries, where the installation of detectors in homes is obligatory. Such action will contribute to reducing the victims of fires or inhalation of toxic gases (carbon monoxide).
PL
Cel: Celem niniejszej publikacji jest przedstawienie najważniejszych aspektów stosowania czujek dymu i czujek tlenku węgla w prywatnych obiektach mieszkalnych, a także wskazanie zalet oraz wad przyjętych rozwiązań systemowych, które mają wpływ na liczbę detektorów montowanych w tego typu obiektach. Artykuł przedstawia również zagadnienia związane z Zintegrowanym Systemem Kwalifikacji (ZSK), tj. opracowanej kwalifikacji rynkowej, dedykowanej monterom i konserwatorom czujek dymu i czujek tlenku węgla. Wprowadzenie: Czujki dymu i czujki tlenku węgla to ważny element zabezpieczeń obiektów mieszkalnych. Dedykowane są one wszystkim właścicielom tych obiektów. W wielu krajach UE obligatoryjne jest montowanie czujek w domach, natomiast obecnie w Polsce wymagane jest jedynie ich certyfikowanie przez producenta. Od 2016 roku w Polsce funkcjonuje ZSK, w którym w roku 2019 wyodrębniono kwalifikacje dla monterów/konserwatorów czujek dymu i czujek tlenku węgla. Dzięki temu osoba posiadająca certyfikat kwalifikacji rynkowej jest przygotowana do samodzielnego montażu i konserwacji urządzeń monitorujących bezpieczeństwo pożarowe. Metodologia: W ramach procesu badawczego wykorzystano badania teoretyczne, takie jak: analiza literatury i dokumentów prawnych, synteza, uogólnianie, wnioskowanie, porównanie oraz analogia. Podczas badań dokonano analizy dokumentów z Polski, Wielkiej Brytanii (głównie Anglii), Niemiec i Francji. Przy ich doborze kierowano się poziomem rozwoju tych systemów w danym kraju oraz dostępnością dokumentów źródłowych. Wnioski: Przedstawiona analiza wymagań w zakresie obowiązku instalacji czujek dymu i czujek tlenku węgla pokazuje, jak różne jest podejście do ich stosowania w Polsce i w wybranych państwach europejskich. W zależności od doświadczeń oraz struktury administracyjnej danego kraju można dostrzec różnorodność przepisów prawnych czy normatywnych. ZSK jest opisanym systemem formalnego uporządkowania i klasyfikacji kompetencji i oferuje społeczeństwu usługi na możliwie najwyższym poziomie jakościowym. Niezbędne jest prawne uregulowanie tej kwestii, tak jak zostało to zrobione w innych krajach UE, gdzie instalacja czujek w domach jest obowiązkowa. Takie działanie przyczyni się do zredukowania ofiar pożarów lub zaczadzeń.
Purpose: The aim of this publication is to present the results of theoretical research – evaluation of normative and legal documents used for the design and installation of voice alarm systems (VAS) in selected European countries. The aim of the research was to analyze and compare the functioning of voice alarm systems in Poland against the background of selected European countries. Introduction: Voice alarm systems are systems installed in buildings that enable the broadcast of warning signals and voice messages for the safety of people in the building. Mandatory use of voice alarm systems in selected buildings became applicable in Poland on January 16, 2006. In Europe, these systems have been present before. Over the years, there has been development of both the devices included in the systems, as well as the normative documents and legal acts that describe these systems. Methods: Within the research process, theoretical research was used, such as: analysis of literature and legal documents, synthesis, generalization, inference, comparison and analogy. As part of the research, documents from such countries as Poland, Great Britain (mainly England), Sweden, Norway, Germany and the Netherlands were analyzed. The selection of individual countries was guided by the level of development of these systems in a given country and the availability of source documents. Conclusions: The presented analysis of the requirements for the use of voice alarm systems shows how different the approach to the use of this type of systems is. Depending on individual experiences and the administrative structure of a given country, a variety of regulations, whether legal or normative (not always normative documents issued by state standardization institutions), can be seen in the field of voice alarm systems application. Unfortunately, one can get the impression that voice alarm systems are still not as popular as fire detection systems. The definition of the requirements for buildings in which the use of voice alarm systems should be obligatory and the requirements for the determination of the required level of speech intelligibility constitute the basis for the consistent development of this type of fire protection equipment. Such requirements should be specified either in legal regulations or in normative acts dedicated to voice alarm systems.
PL
Cel: Celem niniejszej publikacji jest przedstawienie wyników prowadzonych badań teoretycznych – oceny dokumentów normatywnych i prawnych stosowanych do projektowania i instalowania dźwiękowych systemów ostrzegawczych (DSO) w wybranych krajach europejskich. Celem prowadzonych badań było dokonanie analizy i porównania funkcjonowania DSO w Polsce, na tle wybranych krajów europejskich. Wprowadzenie: Dźwiękowe systemy ostrzegawcze to systemy instalowane w obiektach budowlanych, które umożliwiają rozgłaszanie sygnałów ostrzegawczych i komunikatów głosowych na potrzeby bezpieczeństwa osób przebywających w obiekcie budowlanym. Obligatoryjne stosowanie dźwiękowych systemów ostrzegawczych w wybranych obiektach budowlanych zaczęło obowiązywać w Polsce 16 stycznia 2006 r. W Europie systemy te obecne były już wcześniej. Przez lata nastąpił rozwój zarówno urządzeń wchodzących w skład systemów, jak i dokumentów normatywnych oraz aktów prawnych, które opisują te systemy. Metodologia: Autorzy wykorzystali badania teoretyczne, takie jak: analiza literatury i dokumentów prawnych, synteza, uogólnianie, wnioskowanie, porównanie oraz analogia. Dokonano analizy dokumentów z takich krajów jak: Polska, Wielka Brytania (głównie Anglia), Szwecja, Norwegia, Niemcy i Holandia. Przy doborze poszczególnych krajów kierowano się poziomem rozwoju tych systemów w danym państwie oraz dostępnością dokumentów źródłowych. Wnioski: Przedstawiona analiza wymagań w zakresie wykorzystania dźwiękowych systemów ostrzegawczych za granicą pokazuje, jak różne jest podejście do stosowania tego typu systemów. W zależności od indywidualnych doświadczeń oraz struktury administracyjnej danego kraju można dostrzec różnorodność przepisów, czy to prawnych, czy normatywnych w zakresie stosowania DSO (nie zawsze są to dokumenty normatywne wydane przez państwowe instytucje normalizacyjne). Niestety można odnieść wrażenie, że dźwiękowe systemy ostrzegawcze wciąż nie cieszą się taką popularnością, jak systemy sygnalizacji pożarowej. Określenie zasadniczych wymagań w zakresie obiektów, na terenie których stosowanie DSO powinno być obligatoryjne oraz wymagań w obszarze określenia wymaganego poziomu zrozumiałości mowy stanowi podstawę do konsekwentnego rozwoju tego typu zabezpieczeń przeciwpożarowych. Powyższe wymagania powinny być określone albo w przepisach prawa, albo w aktach normatywnych dedykowanych dźwiękowym systemom ostrzegawczym.