The aim of this paper is to present strong maximum principles for infinite systems of parabolic differential-functional inequalities with nonstandard initial inequalities with sums in relatively arbitrary (n+l)-dimensional time-space sets more general than the cylindrical domain.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
In this paper we consider infinite systems of parabolic differential-functional inequalities with nonstandard initial inequalities with integrals. For that systems we give strong maximum principles in relatively arbitrary (n+1)-dimensional time-space sets more general than the cylindrical domain.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The purpose of this paper is to present strong maximum principles for infinite systems of parabolic differential-functional inequalities with initial inequalities in relatively arbitrary (n+1)-dimensional time-space sets more general than the cylindrical domain.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The aim of the paper is to prove a uniqueness criterion of a classical solution of a biparabolic problem in an unbounded domain with a curvilinear boundary.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
An HPLC method for determination of α- and γ-tocopherol in rat blood has been optimized and validated. The optimum means of separation and analysis of tocopherol homologs were selected on the basis of proce-dures found in the literature; documentary evidence is presented which shows precision and accuracy were satisfactory. Spectrofluorimetric detec-tion was performed after separation on a Separon SGX NH2 analytical column with n-hexane-2-propanol, 97:3, as mobile phase; racemic tocol was used as internal standard. A suspension of erythrocytes was saponified and tocopherols were extracted in the presence of BHT, ascorbic acid, and pyrogallol. Plasma samples were extracted without saponification but with antioxidant protection. Validation revealed that intra-day and inter-day RSD in plasma were 0.78% and 4.15%, respectively, for α-tocopherol and 4.03% and 13.155%, respectively, for γ-tocopherol. Intra-day RSD for erythrocytes were 3.75% and 2. 89% for α-tocopherol and γ-tocopherol, respectively. Absolute percentage recovery from plasma and erythrocytes was 99.8 ± 7.5 and 94 ± 9.0, respectively, for α-tocopherol and 100.2 ± 7.5 and 96.9 ± 7.8, respectively, for γ-tocopherol. Limits of detection in plasma and erythrocytes were 0.005 and 0.002 μg mL-1, respectively, for α-tocopherol and 0.002 and 0.0015 μg mL-1, respectively, for γ-tocopherol. Limits of quantification in plasma and erythrocytes were 0.015 and 0.006 μg mL-1, respectively, for α-tocopherol and 0.006 and 0.0045 μg mL-1, respectively, for γ-toco-pherol.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The uniqueness of classical solutions to inverse parabolic semilinear problems together with nonstandard initial conditions, for the operator [formula].
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.