This paper presents the results of experimental investigation of thermophysical properties of material manufactured with 3D printing technology with the use of fused deposition modelling (FDM) method. Cylindrically shaped samples with a diameter of 50.8 mm and with various fill density (from 10 to 100%) were prepared. The investigated material was PLA (polylactic acid, polylactide). The investigation was carried out in order to determine the density, thermal conductivity, thermal diffusivity and specific heat of tested material. The main aim of this paper was to determine the influence of fill density on thermal conductivity. The results can be useful in designing thermal insulation manufactured with rapid prototyping methods, operating in relative low temperature conditions (< 100°C).
PL
W pracy zaprezentowano wyniki pomiarów parametrów termofizycznych przegród izolacyjnych wytwarzanych w technologii druku 3D metodą osadzania topionego materiału FDM (ang. fused deposition modelling), która jest jedną z metod przyrostowych szybkiego prototypowania. Wytworzono próbki walcowe o średnicy 50,8 x 10 mm o różnym współczynniku wypełnienia od 10 do 100%. Próbki zostały wydrukowane z poliaktydu PLA (ang. polylactic acid, polylactide). Dokonano pomiaru gęstości, współczynnika przewodzenia ciepła, współczynnika dyfuzyjności cieplnej oraz ciepła właściwego. Celem eksperymentu było określenie wpływu współczynnika gęstości wypełnienia, a pośrednio gęstości na współczynniki przewodzenia ciepła. W szczególności zastosowanie pustych przestrzeni wypełnionych powietrzem (porów) znacząco wpływa na zmianę współczynnika przewodzenia ciepła w stosunku do pełnego materiału. Wyniki badań mogą być przydatne do projektowania wszelkiego rodzaju przegród i obudów termoizolacyjnych wytwarzanych metodą szybkiego prototypowania, pracujących w stosunkowo niskich temperaturach (< 100°C).
EN
Among the variety of products for thermal insulation in industry the aerogel blankets have received significant attention because of their unique properties and wide range of applications. This paper presents the basic properties, fields of application and results of experimental study of Pyrogel XT, which is a type of high temperature aerogel blanket. It is formed of silica aerogel and reinforced with glass fiber batting. In comparison with traditional insulating materials Pyrogel XT is much more efficient thermal insulation with wide temperature range of application (-40÷650ºC). It also has the lowest thermal conductivity of any known solid material. Experimental investigation of thermophysical properties of Pyrogel XT was carried out by using traditional and modern research methods. The traditional method utilized a simplified single-plate Poensgen apparatus. The modern approach was performed on a UnithermTM model 2022 thermal conductivity instrument which uses a guarded heat flow meter method according to ASTM E1530 standard. Results obtained from both devices were compared and analyzed.
PL
Spośród wielu wyrobów termoizolacyjnych stosowanych w przemyśle maty aerożelowe zyskują duże zainteresowanie ze względu na wyjątkowe właściwości oraz szeroki zakres zastosowań. W pracy zaprezentowano właściwości, obszary zastosowań i wyniki eksperymentalnych badań cieplnych maty aerożelowej Pyrogel XT, będącej nowoczesnym materiałem termoizolacyjnym. Badany materiał jest złożony z aerożelu krzemowego wzmocnionego dodatkiem włókna szklanego. W porównaniu do tradycyjnych materiałów termoizolacyjnych Pyrogel XT odznacza się szczególnymi właściwościami, do których należy najniższa, spośród wszystkich dostępnych termoizolacji przemysłowych, wartość współczynnika przewodzenia ciepła przy jednocześnie szerokim temperaturowym zakresie stosowania (-40ºC÷650ºC). Pyrogel XT posiada również najniższy współczynnik przewodzenia ciepła spośród znanych ciał stałych. Badania eksperymentalne właściwości termofizycznych aerożelu Pyrogel XT przeprowadzono metoda tradycyjną oraz metodami nowoczesnymi. Do badań tradycyjnych wykorzystano uproszczony jednopłytowy aparat Poensgena. W badaniach metodą nowoczesną wykorzystano stanowisko badawcze UnithermTM 2022 wyposażone w miernik przepływu strumienia ciepła pracujący zgodnie z normą ASTM E1530. Wyniki uzyskane z obu urządzeń porównano i poddano analizie.
PL
W artykule zaprezentowano wstępne wyniki badań automatycznego kotła na pellet drzewny pod kątem wymagań normy PN-EN 303-5:2012. Badano kocioł o nominalnej mocy cieplnej 28kW. Dokonano pomiaru mocy cieplnej, temperatury wlotowej i wylotowej z kotła, zbadano emisje CO2, CO, NO i NO2, dokonano pomiaru temperatury spalin. Badano wpływ geometrii turbulizatora spalin na temperaturę spalin a tym samym oszacowano stratę wylotową. Dodatkowo w pracy wyznaczono ciepło spalania pelletu drzewnego i oszacowano jego wartość opałową. Na tej podstawie została określona sprawność cieplna kotła.
EN
The article presents the preliminary results of experimental investigation of the automatic pellet boiler according to the PN-EN 303-5 standard requirements. The boiler with the nominal power of 28 kW was investigated. The measurements of thermal power and inlet and outlet temperature of the boiler were carried out. Additionally the emissions of CO2, CO, NO and NO2 were investigated as well as the flue temperature. The influence of the geometry of the flue turbulence mixer for the flue temperature was also investigated, therefore the loss at outlet could be evaluated. Moreover, the HHV and LHV of investigated pellet was carried out, what helped with the thermal efficiency determination.
4
Content available remote Comparable analysis of an investigation of biomass energetic properties
EN
This paper presents the comparable analysis of the investigation of energetic properties of two types of biomass. The research was made on the manual and semi-automatic oxygen-bomb calorimeter KL-12Mn. The basic energetic properties include calorific value and heating value. Calculations were made according to the PN-ISO 1928 standard. The research was made for basket willow and paulownia tomentosa samples. To determine the average value of each parameter samples of each kind of biomass were researched three times on both devices, which increased the accuracy of methods. The paper also includes the uncertainty analysis.
PL
W pracy zawarto analizę porównawczą właściwości energetycznych dwóch rodzajów biomasy stałej, wyznaczonych przy pomocy kalorymetru ręcznego oraz półautomatycznego KL-12Mn. Do podstawowych właściwości paliw stałych, które zostały wyznaczone, należą ciepło spalania i wartość opałowa, których obliczenia zostały przeprowadzone zgodnie z normą PN-ISO 1928. Analizie poddano próbki wierzby energetycznej oraz paulowni puszystej. Próbka każdego z paliw została poddawana trzykrotnym pomiarom, zarówno w urządzeniu ręcznym, jak i półautomatycznym, dzięki czemu można było wyznaczyć średnią wartość każdego z parametrów Analizę uzupełniono o rachunek niepewności pomiarowych.
PL
W ostatnich latach obserwuje się wzrost zainteresowania układami do skojarzonego wytwarzania ciepła i energii elektrycznej (ang. CHP Combined Heat and Power) z wykorzystaniem paliw gazowych. Kogeneracja to zamiana energii zawartej w paliwach na ciepło i/lub chłód, energię elektryczną lub mechaniczną, realizowana w jednym urządzeniu. Skojarzone wytwarzanie energii może być realizowane zarówno na dużą skalę w elektrociepłowniach zawodowych jak i w tzw. skali mikro, czyli przy użyciu agregatów kogeneracyjnych. Artykuł przedstawia wyniki eksperymentalne krótkoo-kresowego badania efektów pracy małej jednostki kogeneracyjnej GECC60A2N firmy AISIN. Kogenerator o nominalnej mocy elektrycznej 6 kW wytwarza energię elektryczną oddawaną do uczelnianej sieci oraz ciepło oddawane do zasobnika CWU. Dokonano pomiaru przebiegu charakterystycznych temperatur, mocy oraz sprawności. Chwilowa sprawność elek-tryczna wynosiła 24,8%, natomiast średnia sprawność elektryczna 24,3%. Chwilowa sprawność cieplna sięgała 46,0% natomiast średnia sprawność cieplna już tylko 38,5%. Deklarowany przez producenta nominalny EUF powinien wynosić 85% natomiast maksymalna chwilowa wartość tego wskaźnika wyniosła 70,9%, natomiast jej średnio-dzienna wartość 62,8%.
EN
In recent years, an interest in combined heat and power units with using gaseous fuels has increased. Cogeneration is the conversion of the chemical energy of fuels for heating and/or cooling, electricity, implemented in a single device. Combined power generation can be accomplished both in heat and power plants on a large scale and in CHP units in so-called micro scale. The article presents the results of experimental research of work efficiency of short-term small cogeneration unit GECC60A2N AISIN. CHP unit with nominal electric power 6kW generates electricity and heat, which then are transmitted to the local network and to the hot water storage cylinder located in a laboratory room. The aim of the research was to make calculations of characteristic temperatures of the unit, its power and efficiency. Temporary electrical efficiency was 24.8%, while the average electrical efficiency 24.3%. Instantaneous thermal efficiency reached 46.0% while the average thermal efficiency is only 38.5%. Declared by the manufacturer nominal EUF shall be 85% and the maximum instantaneous value of EUF is 70.9%, while its average-daily value 62.8%.
first rewind previous Strona / 1 next fast forward last