Analysis of methods for demodulation of free induction decay signal that are suitable for use in pulsed nuclear quadruple resonance radiospectrometers was performed. The structure and MATLAB Simulink model of the receive path of radiospectrometer was synthesized, in which the Software Defined Radio technology was chosen for the implementation of a quadrature detector with a filtration and quadrature reflection suppression system. The application of the principle of direct digitization of the signal made it possible to significantly reduce the length of the analog portion of the receiver, and, consequently, reduce the noise of the useful signal and the level of out-of-band higher order spectral components.
PL
Przeprowadzono analizę metod demodulacji sygnału zaniku indukcji swobodnej, które są odpowiednie do stosowania w impulsowych radiospektrometrach jądrowego rezonansu kwadrupolowego. Opracowano strukturę i model ścieżki odbiorczej radiospektromeru w środowisku MATLAB Simulink, w którym do realizacji kwadraturowego detektora z układem filtracji i tłumienia odbicia kwadraturowego wybrano oprogramowanie Software Defined Radio. Zastosowanie zasady bezpośredniej cyfryzacji sygnału pozwoliło znacznie zmniejszyć długość analogowej części odbiornika, a w konsekwencji zmniejszyć szum sygnału użytecznego oraz poziom pozapasmowych składowych widmowych wyższych rzędów.
2
Content available remote Principles of computer planning in the functional nasal surgery
EN
The theoretical foundations and principles of computer planning for functional rhinosurgical interventions are proposed in this paper. The theoretical base, stages and possibilities of computer planning for functional nasal surgery are described. Computed surgical planning should be based on a complex anatomical and functional model, that combines data from X-ray computed tomography (X-ray CT) with the results of functional studies from rhinomanometry. Practical recommendations for evidence based surgical computer planning are discussed. Future of proposed method is to study the effect of various anatomical structures of the nasal cavity on the aerodynamic characteristics of the nasal airways and the creation of a database with containing information about the type changes of nasal resistance at typical rhinosurgical interventions.
PL
W artykule zostały zaproponowane podstawy teoretyczne i zasady komputerowego planowania zabiegów neurochirurgii czynnościowej. Zostały opisane podstawy teoretyczne, etapy i możliwości planowania komputerowego w czynnościowej chirurgii nosa. Planowanie komputerowe w chirurgii powinno bazować na kompleksowym anatomicznym i funkcjonalnym modelu, który zawiera wyniki rentgenowskiej tomografii komputerowej i badań funkcjonalnych rynomanometrii. Zostały omówione praktyczne zalecenia dotyczące komputerowego planowania opartego na dowodach w chirurgii. Przyszłością zaproponowanej metody jest zbadanie wpływu różnych struktur anatomicznych jamy nosowej na charakterystyki aerodynamiczną nosowych dróg oddechowych i stworzenie bazy danych zawierającej informacje o zmianach oporu nosowego przy typowych zabiegach neurochirurgicznych.
3
Content available remote Mathematical control system of grid-tied multilevel voltage inverter
EN
The paper synthesizes the control law and computer model for grid-tied multilevel inverter of solar module that allows to hold the solar module operation within the point of maximum power output, which increases its efficiency. The improved models of the direct-axis and quadratureaxis components of inverter current regulator that allow the preservation of power, frequency and voltage balance in the power grid were suggested. The digital realization of control system could be used in smart grid technology of power distribution within electric loss minimization.
PL
W artykule zostały sformułowane zasady sterowania oraz model komputerowy dla wielopoziomowego przekształtnika grid-tied modułu słonecznego, które pozwalają utrzymać działanie modułu słonecznego w punkcie maksymalnej mocy wyjściowej, co zwiększa jego efektywność. Zaproponowano udoskonalone modele jedno i czterokwadraturowych składowych regulatora prądu przekształtnika, które poprawiają zachowanie mocy, częstotliwości i napięcia w sieci energetycznej. Cyfrowa realizacja systemu sterowania może być użyta w technologii smart-grid dystrybucji energii z minimalnymi stratami.
EN
The possibilities of use of intelligent systems in automation of production and technological processes are considered. The intelligent system for optimal control of copper concentrate blending and melting is developed. The paper presents the results of the investigation of the intelligent system for optimal control of copper concentrate blending and melting using neural network (Matlab NNTool), adaptive neuro-fuzzy (hybrid network Matlab Anfis) and fuzzy inference (Matlab Fuzzy Logic) modelling.
PL
W artykule opisane zostały możliwości wykorzystania inteligentnych systemów sterowania w automatyzacji procesów produkcyjnych I technologicznych. Przedstawiony został system do optymalnego sterowania topieniem i wzbogacaniem koncentratu miedzi. W artykule przedstawiono również wyniki badań symulacyjnych przedstawionego systemu z wykorzystaniem sieci neuronowych (Matlab NNTool), rozmytych (sieć hybrydowa Matlab ANFIS) i logiki rozmytej (Fuzzy Logic).
5
Content available remote Determination of blood flow velocity in vessels of the bulbar conjunctiva
EN
The paper presents the methods and the system for registration of digital video recordings of the sclera with a spatial resolution of 2 μm. The pulsed illumination of the sclera was used to eliminate the image blurring caused by the continuous movement of the eyes. At evaluation of blood flow velocity the stabilization of the position of recorded images relatively to the first image frame is used and the trajectory of displacement of the bulbar conjunctiva of the eye is determined.
PL
W artykule omówiono metody oraz opisano system do rejestracji cyfrowych nagrań wideo twardówki z rozdzielczością przestrzenną 2 μm. Zastosowano impulsowe oświetlenie twardówki w celu eliminacji rozmycia obrazu spowodowanego przez ciągły ruch gałek ocznych. Przy ocenie szybkości przepływu krwi przeprowadza się stabilizację pozycji zarejestrowanych obrazów względem pierwszej ramki obrazu oraz wyznacza się trajektorię przemieszczenia spojówki gałki ocznej.
EN
The article describes the principles of a highly sensitive photometer based on modern CCD digital cameras and laptop. The photometer is designed to measure the absolute brightness of the visual objects, which are formed on the screen of the monitor. The examples of the determination of the integrated brightness of R, G, and B pixel elements, of which the image of a visual object is formed for several types of monitors are given.
PL
Artykuł opisuje zasady budowę i zasadę działania bardzo czułego fotometru opracowanego na nowoczesnych wideo kamerach cyfrowych opartych na strukturach CCD i laptopie. Fotometr przeznaczony jest do pomiaru absolutnej jaskrawości obiektów wyświetlanych na ekranie monitora. Dla kilku typów monitorów zostały podane przykłady wyznaczenia zintegrowanej jaskrawości dla wartości R, G i B elementów pikseli, z których formowany jest wizualny obraz obiektu.
EN
A pulse sequence shaper for the pursuance of the research using a wide spectrum of radiospectroscopy and relaxation methods in NQR is proposed. The distinctive feature of this product is its implementation with the application of a multi-functional programmable frequency synthesizer suitable for high-speed amplitude and phase manipulations.
EN
In this article, the data of a quantitative estimation of the visual system light sensitivity of healthy people and the light-sensitivity changes in eyes of patients with arterial hypertension and ischemic optic neuropathy are given. Diagnostic usefulness of the photometric methods for assessing the state of the light sensitivity are discussed.
PL
W artykule opisano metody fotometryczne pozwalające określić aktualny stan układu wzrokowego zdrowego człowieka pod względem czułości na bodźce świetlne. Opisane metody pozwalają diagnozować zmiany czułości wzroku pacjentów z nadciśnieniem naczyń układu wzrokowego oraz neuropatią nerwów wzrokowych. Przedstawiono wyniki badań eksperymentalnych przeprowadzonych podanymi metodami.
9
Content available remote Oculographic means for human retina functional state integral estimation
EN
The usefulness of electrooculography and videooculography for human retina functional state estimation is discussed. The method of synchronous video- and electrooculagrams recording is proposed and its benefits are underlined. An original algorithm of eye pupil detection is described.
PL
W artykule omówiono przydatność zastosowania elektrookulogafii i wideookulografii do oceny stanu funkcjonalnego siatkówki ludzkiego oka. Przedstawiono metodę synchronicznego rejestrowania wideo- i elektrookulogramów i wykazano jej zalety. Opisano nowo opracowany algorytm lokalizacji i odtwarzania trajektorii ruchów źrenic oraz śledzenia zmian ich średnic.
EN
A new method for determining electric and thermal characteristics of Peltier devices is analyzed with the aim of optimization of Peltier devices. Obtained results give the possibility to optimize thermoelectric cooler systems to reach most efficient operating state and to achieve the lowest possible temperature. In optimized by proposed method four stage Peltier cooling cascade the achieved temperature could be near to the superconducting transition temperature of HgBa2CaCu2O6+?. Peltier device is not damaged during the test process and still can be used.
PL
W artykule przeanalizowano nową metodę wyznaczania elektrycznych oraz termicznych parametrów ogniw Peltiera. Otrzymane wyniki dają możliwość optymalizowania chłodziarek termoelektrycznych w celu osiągnięcia najbardziej efektywnego punktu pracy. W czterostopniowej chłodziarce termoelektrycznej zoptymalizowanej przy użyciu proponowanej metody otrzymana temperatura może być bardzo bliska temperaturze nadprzewodnictwa HgBa2CaCu2O6. Badany element Peltiera nie ulega uszkodzeniu podczas testu i może być dalej używany.
11
Content available remote Compensation bridge circuit with temperature-dependent voltage divider
EN
The bridge circuit with temperature-dependent voltage divider for compensation of cold-junction temperature of thermocouple is described. The proposed circuit allows reducing the influence of cold-junction to less than 0,1„a. for thermocouples of the K-type (chromel - alumel) and L-type (chromel - copel).
PL
W artykule opisano mostkowy układ kompensacji wolnych końców termopary zawierający zależny od temperatury dzielnik napięcia. Opracowany układ pozwala zmniejszyć wpływ zmian temperatury wolnych końców na wynik pomiaru poniżej 0,1.. dla termopar typu K (chromelalumel) i typu L (chromel-kopel).
12
Content available remote Approximation of sensor output data using Chebyshev-Laguerre polynomials
EN
The integral Laguerre transform is generalized by introduction of scale factor and argument to arbitrary power. The possibility of usage of such transforms for approximation of sensor output data, filtration of the signals in linear filter models and numerical determination of signal derivatives is described.
PL
Całkowa transformata Laguerre'a może być uogólniona za pomocą wprowadzenia współczynnika skalowania i argumentu w dowolnej potędze. Opisano wykorzystanie takich całkowych transformat do aproksymacji danych wyjściowych sensorów, filtracji sygnałów w liniowych modelach filtrujących i wyznaczenia pochodnych dla sygnałów.
EN
The requirements for the design of portable device for measuring thermal conductivity based on the method of local heat influence are theoretically formulated. The influence of the heat exchange with surrounding environment, the contact thermal resistance between the probe and the surface is discussed. Also, the influence of the size of heat influence zone on the accuracy of measurement of the thermal conductivity of materials is considered.
PL
Sformułowano teoretyczne podstawy projektowe dla przenośnych urządzeń do pomiaru przewodności cieplnej materiałów metodą lokalnego wpływu ciepła. Opisano wpływ wymiany cieplnej z otoczeniem, rezystancji cieplnej kontaktu sondy z powierzchnią materiału badanego. Przeanalizowano również wpływ rozmiaru powierzchni strefy wnikania ciepła na dokładność pomiaru przewodności cieplnej materiałów.
EN
Bridge resistive transducers based on thin film thermoresistors were investigated. The temperature dependencies of resistance errors introduced by the method of two-layer structure are obtained. The microprocessor temperature device is elaborated on the base of shifted two-layer resistive structures.
PL
W artykule opisano przetworniki mostkowo-rezystancyjne zbudowane na bazie cienkowarstwowych termorezystorów. Otrzymano temperaturowe zależności opisujące niedokładności przetwarzania spowodowane przez dwuwarstwową strukturę termorezystancyjną. W oparciu o dwuwarstwową strukturę przetwornika opracowano mikroprocesorowy przyrząd pomiaru temperatury.
PL
Przedstawiono układ kompensacji temperatury wolnych końców termopary z wykorzystaniem tranzystorowego źródła napięcia zależnego od temperatury, który umożliwia zmniejszenie błędu bezwzględnego kompensacji poniżej 0,1°C dla różnych typów termopar.
EN
The circuit for temperature compensation of cold junctions of thermocouple that includes the temperature-dependent transistor voltage source is proposed. The circuit allows reducing the absolute compensation error to less than 0.1°C for different types of thermocouples.
EN
In the proposed article, the question of production (service) quality assessment with the use of expert systems concerning the consumer requirements and expectations is under consideration.
PL
W artykule opisano zagadnienie zarządzania jakością produkcji (usług) z wykorzystaniem systemu ekspertowego w celu spełnienia wymagań i oczekiwań konsumentów.
EN
The analysis of inaccuracy sources in test setup for a new method of determining the electric and thermal characteristics of Peltier devices is presented. An improved experimental setup, including a new method of two-stage cooling, based on liquid coolant, is proposed.
PL
Przedstawiono analizę źródeł niedokładności układu do testowania nowej metody wyznaczania charakterystyk elektrycznych i cieplnych modułów Peltiera. Zaproponowano ulepszoną wersję stanowiska badawczego z zastosowaniem metody chłodzenia dwustopniowego z wykorzystaniem ciekłego czynnika chłodzącego.
18
Content available remote Sensor systems with optical channel of information transferring
EN
In this paper, the temperature characteristics of the helical pitch and the anisotropy of refractive index in cholesteric liquid crystals (CLC) as well as the characteristics: the helical pitch in CLC layers versus the concentrations of vaporous acetone, ethanol and ammonia, are presented. The possibilities of designing devices based on optical properties of liquid crystal planar structures are discussed and an optic planar waveguide, a splitter and an amplifier for a sensor system with optical channel for environment monitoring are proposed.
PL
W artykule zaprezentowano i omówiono charakterystyki przedstawiające zależność długości skoku helisy w cholesterycznych ciekłych kryształach (CLC) oraz anizotropii współczynnika załamania CLC od temperatury, a także zależność długości skoku helisy od stężeń par acetonu, etanolu i amoniaku, pod kątem wykorzystania tych właściwości w sensorowych systemach monitoringu środowiska. Opisano również strukturę światłowodu planarnego, splittera i wzmacniacza optycznego opartą o właściwości warstw ciekłokrystalicznych.
19
Content available remote Multirange code-controlled active resistance imitator
PL
Badano wpływ rezystancji przewodów łączeniowych oraz rezystancji załączonych elementów komutacyjnych na dokładność odtworzenia rezystancji w aktywnych imitatorach rezystancji sterowanych kodowo. Opisano kombinowany sposób nastawiania zakresów imitowanej rezystancji oraz układ aktywnego imitatora rezystancji niezależnego od wpływu rezystancji przewodów i przełączników, który pozwala na przekazywanie wzorcowych miar rezystancji (nawet niskich) na odległość z zachowaniem wysokiej dokładności.
EN
The influence of connecting wires resistance and contact resistance of commutating elements on the accuracy of resistance imitators has been investigated. A new combined technique of setting the range of imitated resistance, as well as schematic design of an active resistance imitator independent of the influence of wire resistance and commutating elements is proposed. This construction allows the transfer of standard unit measures of resistance, with standard accuracy, to remote points even for low nominal values of standard resistances.
20
Content available remote Microprocessor temperature meter for dentistry investigation
EN
The peculiarities of measuring the temperature on the root surface of a tooth by means of thermoelectric transducers during obturation are described. Linearization methods for transfer functions of thermoelectric transducer within the range of interest in dentistry investigation: from 20°C to 60°C are discussed. The scheme of microprocessor temperature meter with the basic relative measurement error less than 1% is presented.
PL
Opisano uwarunkowania pomiarów temperatury na powierzchni korzeni zębów za pomocą czujników termoelektrycznych podczas obturacji. Rozpatrzono metody linearyzacji funkcji przetwarzania czujników termoelektrycznych dla zakresu temperatury od 20°C do 60°C, istotnego w badaniach stomatologicznych. Przedstawiono układ mikroprocesorowego miernika temperatury, którego błąd względny podstawowy wynosi poniżej 1%.