Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Measurements of the so-called lost alpha particles escaping from thermonuclear plasma in future tokamaks (such as ITER) for energy production would be essential for monitoring the energy balance in these devices. The detection would have to be carried out in a harsh environment (with high nuclear radiation fluxes, high temperature, etc.), which limits the use of common semiconductors for charged particle detection. Diamond seems to be an attractive material for alpha particle detectors in these conditions. In this paper an analysis of properties of a diamond detector for spectrometric alpha measurements is reported. A high purity CVD (chemical vapour deposition) single crystal diamond detector was used, fabricated for this dedicated application by the Diamond Detector Ltd. The energy calibration was carried out using a triple alpha particle isotope source, AMR33 (239Pu, 241Am, 244Cm). A very good energy resolution, ca. 20 keV at ca. 5.5 MeV had been obtained, which is comparable to that of the silicon detector. The linearity of the diamond detector amplitude response to the alpha particle energy was analyzed with the use of mono-energetic (0.4–2 MeV) ion beam from a Van de Graaff accelerator. Results of the measurements using the AMR33 source deviate at most 30 keV from the calibration line obtained in this way.
PL
Przekrój czynny na absorpcję neutronów termicznych w ośrodku niejednorodnym (ziarnistym) jest niższy niż w odpowiadającym ośrodku jednorodnym zawierającym te same składniki w tych samych ilościach. Taka niejednorodność może wystąpić bądź w naturalnym ośrodku skalnym, bądź w próbce użytej do badań. W pracy pokazano wpływ granulacji próbki skalnej na obserwowany przekrój czynny absorpcji mieszanin ziaren z roztworami absorbenta, jak również na interpretowany stąd przekrój czynny samej skały. Pomiary wykonano na stanowisku przy impulsowym generatorze neutronów w IFJ, używając próbek diabazu o drobnych (< 4 mm) i dużych (od 6,3 do 12,8 mm) ziarnach. Obliczenia teoretyczne przeprowadzono w oparciu o wcześniej opracowaną teorią absorpcji neutronów w ośrodku ziarnistym, zweryfikwaną w eksperymentach na modelach o kontrolowanej ziarnistości i dokładnie znanej absorpcji składników. Pokazano sposób oceny, czy próbka materiału użyta w pomiarze jest jednorodna z punktu widzenia transportu neutronów.
EN
The thermal neutron absorption cross section of a heterogeneous material is lower than of the corresponding homogeneous one which contains the same components. When rock materials are investigated the sample contains usually grains which create heterogeneity. The heterogeneity effect depends on the mass contribution of highly- and low-absorbing centres, on the ratio of their absorption cross sections, and on their sizes. An influence of the granulation of silicon and diabase samples on the absorption cross section measured with Czubek's method has been experimentally investigated. A 20 per cent underestimation of the absorption cross section has been observed for the diabase grains of sizes from 6.3 to 12.8 mm.
EN
The pulsed neutron generator in the Institute of Nuclear Physics in Kraków operates as a pulsed and/or stationary neutron source. Its experimental set-up for research of the time-dependent thermal neutron fields in various media is presented. The electronic control systems for the generator and for data acquisition, necessary to assure the required measurement conditions, have been designed and built by the authors. The new electronic equipment makes it possible to do the measurements with high accuracy and repeatability. The macroscopic absorption cross section for environmental materials, like rocks, borehole and formation fluids, are measured routinely using the pulsed neutron source by two methods elaborated in the INP. The pulsed neutron parameters for homogeneous and heterogeneous materials (e.g. containing absorbing centres in a low absorption matrix) can be also measured by the geometrical buckling method on the same experimental set-up. Experiments for materials of variable bulk densities are going on. Other experiments are related to a verification of new theoretical models of thermal neutron scattering in hydrogenous media.
PL
Generator neutronów prędkich działający w Instytucie Fizyki Jądrowej im. Henryka Niewodniczańskiego w Krakowie może pracować zarówno z wiązką ciągłą, jak i impulsową. W pracy opisane jest stanowisko pomiarowe do badania niestacjonarnych pól neutronowych w różnego rodzaju ośrodkach. Systemy sterowania i kontroli generatora neutronów i stanowiska pomiarowego oraz układy zapewniające utrzymanie odpowiednich i stabilnych warunków pomiarowych zostały zaprojektowane i wykonane przez zespół autorów. Nowoczesne rozwiązania elektroniczne umożliwiają wykonywanie pomiarów z wysoką dokładnością i powtarzalnością. Obecnie stanowisko pomiarowe wykorzystywane jest do pomiaru przekroju czynnego absorpcji neutronów termicznych dla materiałów geologicznych dwiema metodami impulsowymi opracowanymi w IFJ. Ponadto metodą zmiennego bucklingu geometrycznego wyznacza się tzw. impulsowe parametry neutronowe dla ośrodków jednorodnych i niejednorodnych (np. centra absorpcyjne w słabo absorbującym medium). Wykonuje się również eksperymenty dla materiałów o zmiennej gęstości nasypowej. Stanowisko może też być wykorzystywane do eksperymentów służących weryfikacji badań podstawowych dotyczących procesów spowalniania, rozpraszania i dyfuzji neutronów w ośrodkach o ograniczonych rozmiarach, w szczególności zawierających wodór związany w molekułach.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.