Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This study presents a selective high-performance liquid chromatography (HPLC) with diode array detection (DAD) method for the simultaneous estimation of diclofenac sodium and lidocaine hydrochloride in presence of four of their related substances and potential impurities, namely, 2,6-dimethylaniline (DMA), 2,6-dichloroaniline (DCA), N-phenyl-2,6-dichloroaniline (PDCA), and N-chloroacetyl-N-phenyl-2,6-dichloroaniline (CPDCA). Some of these related substances are reported as degradation products as well. Effective chromatographic separation was achieved using Waters Symmetry C18 column, (3.9 × 150 mm, 5 μm particle size) with gradient elution of the mobile phase composed of 0.05 M orthophosphoric acid and acetonitrile. The gradient elution started with 5% (by volume) acetonitrile, ramped up linearly to 65% in 5 min then kept constant till the end of the run. The mobile phase was pumped at a flow rate of 1.5 mL min−1. The multiple wavelength detector was set at 220 nm, and quantification of both drugs was based on measuring their peak areas. The retention times for lidocaine and diclofenac were about 5.5 and 9.5 min, respectively. The reliability and analytical performance of the proposed HPLC procedure were statistically validated with respect to system suitability, linearity, ranges, precision, accuracy, specificity, robustness, detection, and quantification limits. Calibration curves were linear in the ranges of 10–200 μg mL−1 for both drugs with correlation coefficients not less than 0.9998. The proposed method proved to be selective by resolution of the two drugs from their related substances and potential impurities. The validated HPLC method was successfully applied to the analysis of this binary mixture in the combined formulation (ampoules dosage form), and the assay results were favorably compared with a previously reported HPLC method. The proposed method made use of DAD as a tool for peak identity and purity confirmation.
EN
A simple and selective liquid chromatographic method was developed for the simultaneous determination of tenofovir disoproxil fumarate (TEN) and emtricitabine (EMT) in combined tablets. The method is based on separation of TEN and EMT on a Zorbax SB-C8 column, 5 μm, 4.6 × 250 mm, with a mobile phase consisting of 50 mM disodium hydrogen phosphate-acetonitrile (50:50, v/v). The mobile phase contains 0.1% triethylamine (TEA) and was adjusted to pH 6.0. Quantification of the analytes is achieved with diode array — ultraviolet detector (DAD-UV) at 260 and 280 nm for TEN and EMT, respectively, based on peak area. Different variables affecting the method were carefully investigated and optimized. Reliability and analytical performance of the proposed method, including linearity, range, precision, accuracy, and detection and quantitation limits, were statistically validated. The high-performance liquid chromatography (HPLC) method was successfully applied for determination of each drug in their binary tablets.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.