Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
We studied the effects of Aeroxide P25 titanium dioxide nanoparticles (TiO2 NPs) with a diameter of 21 nm on induction of DNA damage and long-term survival of three human cell lines: hepatocellular liver carcinoma HepG2, colorectal adenocarcinoma HT29 and lung carcinoma A549. The endpoints examined were DNA breakage estimated by the comet assay and oxidative base damage recognized by formamide-pyrimidine glycosylase (FPG) estimated with the FPG+ comet assay, frequencies of histone H2AX foci and micronuclei, apoptosis, cell metabolic activity measured by mitochondrial activity (MTT) assay and long-term survival measured by colony-forming ability. Each cell line had a different pattern of DNA breakage and base damage vs. nanoparticle (NP) concentration and treatment time. There was no increase in the frequencies of histone H2AX foci and micronuclei as compared to those in the untreated cells. In parallel with these results, no induction of apoptosis has been found in none of the cell lines tested. The reported experiments provided no evidence of the long-term in vitro toxicity of Aeroxide P25 TiO2 NPs, despite a slight decrease in mitochondrial activity and cell survival during the first 72 h.
PL
Dozymetria biologiczna oprócz oszacowania wysokości dawki powinna mieć możliwość rozpoznawania czy napromienione zostało całe ciało, czy tylko jego część. Bardzo dobrze sprawdza się tutaj test chromosomów dicentrycznych, jednak prowadzone są prace również z innymi testami dozymetrycznymi. Wyniki badań wskazują, że test mikrojądrowy nie pozwala jednoznacznie na rozpoznawanie częściowego napromienienia ciała.
EN
Biological dosimetry in addition to the estimation of the absorbed dose should be able to recognize whole or partial body irradiation. The dicentric chromosome test works very well here, however, other dosimetry tests are being examined to recognize partial body irradiation. The research results indicate that the micronucleus test does not explicitly allow the recognition of such a situation.
PL
Radon jest radioaktywnym gazem szlachetnym, obecnym w środowisku człowieka. Jest on drugim po paleniu papierosów czynnikiem odpowiedzialnym za powstawanie raka płuc. W 2019 r. do prawa polskiego została zaimplementowana Dyrektywa Rady Unii Europejskiej 2013/59/EURATOM (tak zwana BSS) wymagająca czynnej ochrony przed stężeniami radonu powyżej 300 Bq/m3. Jednak problem jakie stężenia radonu zwiększają ryzyko powstawania nowotworów płuc jest tematem dyskusji naukowej i nie jest jednoznaczny. Cytogenetyczne efekty działania radonu można pokazać przy pomocy testu kometowego w limfocytach krwi obwodowej oraz przy pomocy analizy częstości mikrojąder w komórkach nabłonkowych pochodzących z worka policzkowego.
EN
Radon is a radioactive noble gas present in the human environment. It is the second factor behind lung cancer after smoking cigarettes. In 2019, the European Council Directive 2013/59/EURATOM (so-called BSS) was implemented into Polish law, requiring active protection against radon concentrations above 300 Bq/m3. However, the problem of what radon levels increase the risk of lung cancer is a topic of scientific discussion and is not clear. The cytogenetic effects of radon can be demonstrated using a comet assay in peripheral lymphocytes or the micronucleus frequency analysis in buccal epithelial cells.
PL
W artykule opisano sposób funkcjonowania TSO w kilku krajach. Termin TSO używany jest dopiero od 10 do 15 lat. MAEA uznaje powstanie TSO za kluczowe do zapewnienia bezpieczeństwa jądrowego. TSO powinny być niezależne od operatorów elektrowni jądrowych i powinny mieć zapewnione stabilne finansowanie. Model organizacyjny TSO: czy to będzie jedna organizacja, czy kilka, jak duże TSO jest potrzebne – jest sprawą otwartą. W Polsce na poziomie oficjalnym nie ma organizacji TSO. Trzy instytuty są zainteresowane w powstaniu TSO (CLOR, IChTJ i NCBJ) i według planów Ministerstwa Energii mają zostać połączone w jedną organizację (łącznie z czwartym instytutem: IFPLM) Narodowe Laboratorium Energii Jądrowej. W kontekście zmian personalnych w Ministerstwie Energii i braku decyzji o budowie elektrowni jądrowych nie wiadomo czy plany dotyczące TSO w Polsce wejdą w życie.
EN
The article describes the functioning of TSO in several countries. The term TSO has only been used for 10-15 years. The IAEA recognizes the development of TSOs as key to ensuring nuclear safety. TSOs should be independent from nuclear power plant operators and should be provided with stable funding. The organizational model of the TSO: whether it will be one organization or several, how big TSO is needed - it is an open matter. In Poland, there is no TSO organization at the official level. Three institutes are interested in the founding of TSO (CLOR, ICHTJ and NCBJ) and according to the plans of the Ministry of Energy they are to be merged into one organization (including the fourth institute: IFPLM) National Laboratory for Nuclear Energy. In the context of personnel changes in the ME and the lack of decision on the construction of nuclear power plants, it is not known whether the plans for TSO in Poland will come into force.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.