Electromagnetic articulography (EMA) is one of the instrumental phonetic research methods used for recording and assessing articulatory movements. Usually, articulographic data are analysed together with standard audio recordings. This paper, however, demonstrates how coupling the articulograph with devices providing other types of information may be used in more advanced speech research. A novel measurement system is presented that consists of the AG 500 electromagnetic articulograph, a 16-channel microphone array with a dedicated audio recorder and a video module consisting of 3 high-speed cameras. It is argued that synchronization of all these devices allows for comparative analyses of results obtained with the three components. To complement the description of the system, the article presents innovative data analysis techniques developed by the authors as well as preliminary results of the system’s accuracy.
PL
W artykule opisano strukturę i funkcjonalność bazy danych artykulograficznych do przechowywania danych z badań przeprowadzanych z wykorzystaniem artykulografu elektromagnetycznego, kamery akustycznej i 3 kamer wideo. Baza danych umożliwia selektywne pobieranie różnych typów danych, w szczególności dotyczących mówcy, sesji nagraniowej, nagrań oraz eksperymentów. Opisano strukturę i budowę bazy danych. Przedstawiono również potencjalne przyszłe zastosowania do przeprowadzania analiz statystycznych oraz w eksperymentach dotyczących inwersji mowy z wykorzystaniem modeli sieci Bayesa.
EN
The article describes the structure and functionality of the articulographic database for storing data from articulographic research using an electromagnetic articulograph, an acoustic camera and 3 video cameras. The database enables selective extraction of various types of data for scientific research and interoperates with programs that carry out experiments. Structure and construction of the database is described. Potential future application in statistical analysis and experiments on speech inversion using dynamic Bayesian networks (DBN) was also presented.
EN
In the paper a measurement method of fluorescence intensity reduction (called photobleaching) caused by excitation light was presented. Intensity of fluorescence light was measured by silicon photomultiplier (SiPM) – sensor which allows single photons detection. It has more compact dimensions and lower bias voltage in comparison to photomultiplier tube, presently used in many laboratory devices. Standard photometric cuvettes with a capacity of 1.6 ml and optical path length of 10 mm were used for the measurements. Sodium fluoresceinate dissolved in 10 mM TRIS buffer at pH 8.5 was used as the fluorescent dye. The solution was tested at a concentration of 100 μg per ml with constant excitation light from LED source over the time of measurement.
EN
The paper presents method for thermal generation reduction in low level light applications, especially where measured phenomena have random character. The algorithm was developed basing on cosmic ray measurements. The main parts of the system are: Silicon Photomultipliers (SiPM), front-end ASIC for amplifying and shaping signals. SiPM is a very sensitive device which can detect single photons. Comparing to a standard photomultiplier SiPM has a compact size, low operating voltage and it is immune to an electromagnetic field. Thermally generated signals are disadvantage of SiPM. This paper presents the measurement method to reduce influence of thermal generation.
EN
The paper stresses the issue of strong temperature influence on the gain of a Silicon Photomultiplier (SiPM). High sensitivity of the detector to light (single photons) requires stable parameters during measurement, including gain. The paper presents a method of compensating the change of gain caused by temperature variations, by adjusting a suitable voltage bias provided by a precise power module. The methodology of the research takes in account applications with a large number of SiPMs (20 thousand), explains the challenges and presents the results of the gain stabilization algorithm.
6
Content available remote Fluorescence detection in microfluidics systems
EN
In this paper, two optical detection systems – first based on the tube and the second one on the silicon photomultiplier are described. The detection system was tested for fluorescent dyes - sodium fluoresceinate and resorufin excitated in two systems: static and dynamic i.e. in PMMA cuvettes and PDMS made microchannels, respectively. Sources of excitation light were 488 and 532 nm wavelength laser diodes and blue/green LEDs (light emitting diodes). In the experiment tube and silicon photomultipliers applied in the above-mentioned systems were compared.
PL
Jako fotodetektory w układach mikroprzepływowych stosuje się urządzenia takie jak matryce CMOS, fotodiody lawinowe czy fotopowielacze lampowe. W ostatnim czasie prowadzone są intensywne badania nad zastosowaniem fotopowielaczy krzemowych jako fotodetektorów. Jest to spowodowane między innymi względami ekonomicznymi oraz dużo łatwiejszą ich mobilnością. W naszym artykule zaprezentowane zostały porównawcze wyniki badań dla dwóch fotopowielaczy – lampowego oraz krzemowego w zastosowaniach w układach mikrofluidycznych.
EN
This paper presents the method for the compensation of the temperature fluctuations in the measurement system based on the Silicon Photomultipliers (SiPM). Temperature has very strong influence on the gain of the detectors. Because single photons are detected and the system is very sensitive, its parameters have to be steady during the measurements. Temperature is being stabilized by changeable bias voltage of the detector. This paper describes how the algorithm of compensation has been determined during series of measurements and presents first results of temperature compensation.
PL
Artykuł opisuje metodę kompensacji zmian temperatury w systemach pomiarowych zawierających krzemowe fotopowielacze. Temperatura ma duży wpływ na wzmocnienie krzemowego fotopowielacza. Ponieważ urządzenie to jest bardzo czułe i potrafi mierzyć pojedyncze fotony, jego parametry muszą być kontrolowane podczas pomiaru. Temperatura jest stabilizowana przez zmiany napięcia polaryzacji. Artykuł prezentuje opis opracowania metody kompensacji na podstawie pomiarów oraz pierwsze wyniki kompensacji temperatury.
EN
This paper presents an efficient measurement system for a low-level light detection, emitted by fluorescent dye. The system setup and measuring method has been discussed. Silicon photomultiplier, which is called Multi Pixel Photon Counter developed by Hamamatsu, has been used as a light detector. Tests has been done for fluorescein and resorufin specimens in 1.5 ml volume PMMA (Polymethyl Methacrylate) cuvettes positioned in a specially designed optical system. Solutions of this dyes were prepared in TRIS buffer with pH factor equal 8. Range of concentrations which has been used for measurements is from 1ug/ml to about 1 pg/ml.
PL
Artykuł przedstawia efektywny system pomiarowy do detekcji światła fluorescencyjnego o niskim natężeniu. Została w nim omówiona konstrukcja systemu oraz metoda pomiarowa. Jako czujnik światła fluorescencyjnego użyty został fotopowielacz krzemowy produkowany przez firmę Hamamatsu. Testy wykonano na próbkach fluoresceiny i rezorufiny umieszczonych w kuwetkach PMMA o pojemności 1,5 ml. Roztwory tych barwników przygotowano w roztworze TRIS o czynniku pH = 8. Stężenia barwników w roztworach, wykorzystane podczas pomiarów zawierają się w przedziale od 1ug/ml do około 1 pg/ml.
PL
W artykule przedstawiono konstrukcję kamery cyfrowej zbudowanej z wykorzystaniem układu FPGA serii Spartan-3. W kompaktowej obudowie został zintegrowany system akwizycji i przetwarzania obrazów pracujący z szybkością 5 ramek na sekundę. Kamera umożliwia efektywne wykorzystanie zasobów układu FPGA do implementacji algorytmów przetwarzania obrazów.
EN
In the paper an architecture of digital camera based on Spartan-3 FPGA device is presented. Acquisition and image processing systems have been integrated in a compact case. The camera is able to process 5 frames per second. Image processing algorithms are effectively executed in FPGA resources.