Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 39

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The paper presents the analysis of the influence of fasteners and connections flexibility on displacements of symmetrical single-bay pitched-roof steel building, including trapezoidal cladding acting as a diaphragm. The purpose of the article was to compare numerical models with and without taking into consideration fasteners and connections flexibility in order to observe the differences in transverse stiffness of the building during modifying model from the simple one to more complex and precise. The analyses were carried out for the 3D structure. Fasteners and connections were substituted by equivalent beam finite elements. Corrugated sheets were replaced by three types of equivalent orthotropic shell models and the influence of the choice of the model on the stiffness of the building was observed. The results showed that in the analysed structure the flexibility of fasteners and connections has negligible effect on transverse displacements of the building in the case of four sides fastening of the sheeting, however in the case of two sides fastening the influence significantly increases.
EN
Due to the technological reasons in modern lightweight steel trusses, fabricated from cold-formed sections, positive eccentricities appear in the truss nodes what induce additional forces in the truss chords. To account for the real load-carrying capacity of truss node area the steel structure research in scale 1:1 were conducted. The experiments consisted of two parts: preliminary and proper one, when conclusions from the first part were applied. Carrying out preliminary studies helped to identify of the research station drawbacks and eliminate most of them, what ensure the appropriate research results. The initial numerical analysis were also conducted what was presented in the paper.
PL
W nowoczesnych konstrukcjach stalowych dźwigarów kratownicowych, wykonywanych z kształtowników giętych na zimno, ze względów technologicznych w węzłach kratownic występują mimośrody dodatnie, które powodują powstanie dodatkowego zginania ze ścinaniem w rejonie węzła. W celu określenia rzeczywistej nośności takiego węzła przeprowadzono badania na modelach konstrukcji kratownicy w skali 1:1. Badania przeprowadzono w dwóch etapach: pierwszym wstępnym oraz drugim, w którym wykorzystano wnioski z etapu pierwszego. Przeprowadzenie badań wstępnych było pomocne w identyfikacji błędów oraz ich późniejszym usunięciu, co przyczyniło się do uzyskania poprawnych i wiarygodnych wyników badań. W artykule przedstawiono również wstępne analizy numeryczne badanego modelu kratownicy.
3
Content available Lekka obudowa w nadbudowach i renowacjach
PL
W artykule przedstawiono możliwości wykorzystania technologii lekkiej obudowy do nadbudowy i renowacji obiektów budowlanych. Opisano kolejne kroki przygotowania inwestycji dotyczącej projektowania i realizacji nadbudowy obiektu budowlanego.
EN
The paper presents the possibilities of use of lightweight building partitions in superstructures and renovations. The article describes the sequence of steps of the superstructure investment preparation.
4
Content available remote Kiedy są niezbędne rysunki warsztatowe konstrukcji stalowych
PL
W wielu przypadkach wymagany prawnie zakres rysunkowej dokumentacji projektowej jest niewystarczający do właściwego wykonania i montażu konstrukcji stalowych. W artykule przedstawiono sytuacje, w których wykonanie rysunków warsztatowych jest niezbędne. Ma to szczególne znaczenie w budownictwie energetycznym.
EN
Legally required range of the design documentation drawings is insufficient in many cases for the proper execution and erection of steel structures. The cases, when the execution workshop documentation is necessary are presented in the paper. It is of particular importance in power engineering building.
5
Content available remote Wymagania stawiane lekkiej obudowie
PL
W artykule omówiono wymagania stawiane lekkim obudowom. Przywołano odpowiednie normy i rozporządzenia dotyczące zagadnień ogólnobudowlanych i techniczno-użytkowych.
EN
The article presents performance requirements for lightweight external wall cladding. Relevant standards and regulations concerning general construction and technical requirements are quoted.
6
Content available remote Układy konstrukcyjne lekkiej obudowy
PL
W artykule przedstawiono rozwiązania konstrukcyjne przegród zewnętrznych lekkiej obudowy jednowarstwowych (nieizolowanych termicznie), wielowarstwowych (izolowanych termicznie) oraz szklano-metalowych. Omówiono procesy modyfikacji konstrukcji ścian. Podano przykładowe rozwiązania.
EN
Structural solutions of single-layer (no thermal insulation) and multi-layer (with thermal insulation) lightweight cladding and metal-glass walls are presented in the paper. The process of wall structure modification is described and example solutions are given.
7
Content available remote Remonty i przebudowy dachów z zastosowaniem elementów lekkiej obudowy
PL
W artykule przedstawiono przykładowe rozwiązania remontów i przebudowy dachów. Omówiono rozwiązania zmiany materiału pokrycia zarówno bez dodawania warstwy izolacyjnej, jak i z ułożeniem dodatkowej warstwy ocieplenia na istniejącej połaci dachowej, a także sposób przebudowy dachu, polegający na ustawianiu nowej, lekkiej konstrukcji nośnej dachu, bezpośrednio na istniejącym pokryciu dachu płaskiego.
EN
The paper presents examples of roof repairs and remodelling projects. Solutions are discussed for replacement of roofing material, with or without an additional insulation layer on the existing roof slope, as well as a method of roof remodelling through setting up new lightweight load-carrying structure directly on the existing flat roof finish surface.
PL
W artykule omówiono podział i charakterystykę lekkich przegród budowlanych. Przedstawiono możliwości zmian elewacji i wykonywania nadbudowy. Opisano kolejne kroki przygotowania inwestycji dotyczącej projektowania i realizacji nadbudowy obiektu budowlanego.
EN
The article discusses the classification and characteristics of light partitions, as well as the primary materials and components used in light cladding: metal, glass and insulation materials.
9
Content available Lekka obudowa. Część 4 – układy konstrukcyjne
PL
Duża dostępność i szeroka oferta materiałów oraz ogromne zapotrzebowanie na trwałe, estetyczne fasady z dużymi przeszklonymi powierzchniami spowodowały szybki rozwój nowoczesnych rozwiązań w dziedzinie metalowo-szklanych ścian osłonowych.
PL
Ściana osłonowa powinna być wykonana z materiałów, które nie stanowią zagrożenia dla otoczenia, i spełniać szereg normowych wymagań funkcjonalno-użytkowych.
11
PL
Wszelkie przegrody budowlane stosowane w obiektach użyteczności publicznej, przemysłowych, magazynowych oraz inwentarskich muszą spełniać stawianie im wymagania odpowiedniej izolacyjności typu R, E oraz I, stosownie do klasy odporności pożarowej budynku, w którym zostaną zastosowane.
12
PL
Wraz z rozwojem technologii budowlanych w ostatnim 50-leciu nastąpiły istotne zmiany w zakresie rozwiązań materiałowokonstrukcyjnych przegród budowlanych. Obudowę obiektów z żelbetowych płyt i bloków prefabrykowanych zastąpiła w wielu inwestycjach tzw. lekka obudowa, zarówno ścienna, jak i dachowa. Nowy cykl artykułów dotyczyć będzie wybranych rodzajów przegród, tzn. zewnętrznych lekkich ścian osłonowych i lekkich pokryć dachowych.
EN
This work describes why trending thin-walled technology is achieving popularity in steel construction sector. A purpose of this article is to present the influence of the cold-formed element cross-section shape on an axial compression and a bending moment resistance. The authors have considered four different shapes assuming constant section area and thickness. Calculations were based on three different steel grades taking into account local, distortional and overall buckling. The results are presented in a tabular and a graphical way and clearly confirm that cross-section forming distinctly impact the cold-formed member resistance. The authors choose these cross-sections that work better in compression state and the other (those slender and high) that function more efficiently are subjected to bending.
PL
W niniejszej pracy, wykorzystując możliwości programu Dlubal RFEM 5.04, przedstawiono efekty uwzględniania współpracy konstrukcji nośnej hali z poszyciem wykonanym z blach trapezowych. Przeprowadzono analizy obliczeniowe kilku wariantów modelu 3D przykładowej hali stalowej. Wyniki obliczeń oraz wnioski zestawiono w tablicach.
EN
Previous construction analysing methods were based on 2D models what is inaccurate and does not give a possibility to use a full, precise members mutual cooperation. In this article authors show an influence of taking into consideration the cooperation between trapezoidal sheeting and structural beam members illustrated with an example of a single storey buildings. This analysis was carried out in the state of the art computer program called Dlubal RFEM 5.04. This paper shows the stiffening profiled sheeting application impact on a general construction mass. 3D numerical calculations were based on a frame construction with 10 metre-high columns and a span of 12 m. Hot rolled truss-column system made out of S235 steel with stiff base in the foundation was used here. Steel profiled sheeting were assumed as an orthotropic surfaces, called diaphragm. Those 3 separate numerical models were analysed. The first one did not consider the cooperation between trapezoidal sheets and the structure. The second did consider the cooperation but only on the roof and the last one account the full integration (on the roof and on longitudinal walls as well). Calculations gave a surprising results. The displacement decreased by about 90% between the first and the second numerical models. Authors also noticed the decrease of general mass by 26%.
EN
One of the major advantages of light gauge steel structures made of cold-formed steel sections is their low weight so the production of typical single-storey steel structures of this kind of profiles is still rising. The well known profiles, e.o. Z-sections, C-sections and the so called hat-sections studied and described in the literature, are used mainly as purlins or truss components. A new profile GEB was patented for the use for primary load-bearing member in fabricated steel frames. According to the code [1] every novel cross section should be tested to assign the deformation shape and bearing capacity. The paper deals with the numerical and experimental research of bearing capacity of cold formed GEB profiles. The deformation shape and limit load was obtained from bending tests. The GEB cross section bearing capacity was also determined according to codes [1, 2].
PL
Jedną z najważniejszych zalet lekkich konstrukcji metalowych, wytwarzanych z kształtowników giętych na zimno, jest ich mała masa, dlatego też, producenci coraz częściej wykorzystują możliwości profili giętych do wytwarzania typowych konstrukcji halowych w budownictwie systemowym. Proces gięcia na zimno, pozwala na formowanie różnego rodzaju przekrojów poprzecznych, które mogą być wykorzystywane jako elementy konstrukcji. Typowe kształty elementów. tzn. Z, C oraz tzw. przekroje kapeluszowe, które zostały przebadane i opisane w literaturze, wykorzystuje się głównie jako płatwie lub części składowe wiązarów kratowych. Nowo opatentowany przekrój typu GEB ma być wykorzystany jako element nośny konstrukcji ramowych. W związku z tym innowacyjny kształt oraz parametry geometryczne przekroju takiego kształtownika, związane z możliwością jego wyprodukowania oraz z warunkami nośności, stateczności oraz sztywności, muszą być optymalne. Według normy PN-EN 1993-1-3, każdy nowo uformowany przekrój powinien być przebadany pod kątem nośności elementu i formy deformacji, dlatego też, ten innowacyjny kształtownik został poddany m.in. badaniom nośności na zginanie. Na ich podstawie została określona wartość nośności przekroju oraz forma jego deformacji. Jednocześnie dla analizowanego elementu zostały przeprowadzone obliczenia nośności przekroju, według normy PN-EN-1993-1-3 oraz numeryczne w programie MARC MENTAT.
EN
This work describes the restraints in the optimization problem. This is an important and complicated issue because it requires taking into account a vast range of information related to the design and production. In order to describe the relations of a specific optimization problem, it is essential to adopt appropriate criteria and to collect information on all kinds of restraints, i.e. boundary conditions. The following paper verifies the various restraints and defines three subsets: design assumptions, technological limitations and standard conditions. The provided classification was made with reference to the analysis of the construction applicability of the newly patented cold-formed profile.
PL
Continual trend to simplify structural elements and find less time-consuming solutions on construction site as well as inevitable increase in labour costs determine for instance elimination of those technological steps that are difficult to automation. Welding additional reinforcements and web stiffeners are great examples of such a step. The method presented in EN 1993-1-8 [8] is a result of long-term studies focused on calculating the moment resistance and stiffness of joints without transverse web stiffeners. Design calculations shown in this paper are based on resistance and stiffness growth analysis applying supplementary web plates. Authors consider validity of this solution due to construction effort and building durability remembering about minimization of the costs.
EN
This work is dedicated to establishing the load carrying capacity of tensed and compressed truss’ nodes made of cold-formed open cross sections. The occurrence of bending in the truss’ nodes is the result of a specific production technology for system lattice girders assumed by the designer and the producer. The aim of this research is to present the methodology of conduct for creation of computational models that best depict the behaviour of truss members welded from cold-formed sections with positive eccentricities in the node. Gradual introduction of more complex computational analysis methods allowed for following, how the assumed method influenced the results and facilitated their analysis and estimation.
PL
Konstrukcje wsporcze linii elektroenergetycznych były i są projektowane zgodnie ze specjalistycznymi normami, innymi niż stosowane w budownictwie. Dotyczą one zarówno oddziaływań środowiskowych, takich jak temperatura, wiatr, oblodzenie i oddziaływania stałe (naciąg przewodów, osprzęt), jak i zasad wymiarowania. W artykule przedstawiono wyniki analiz porównawczych dotyczących wpływu zmian wprowadzonych w normach europejskich na stalową konstrukcję słupa wsporczego.
EN
Supporting structures of the power lines were and are designed in accordance with the standards which differ from the guidelines being in force in the construction industry. They concern both the environmental impacts, such as temperature, wind, impact damage and dead loads (tension wires, accessories), aswell as the principles of designing. The results of the parametric analyses concerning the effects of introduced changes in supporting structures are presented in the paper.
20
Content available remote Badania stanów granicznych stalowych kasetonów elewacyjnych
PL
Zakres i program badań eksperymentalnych stanów granicznych nośności i użytkowania stalowych kasetonów elewacyjnych w warunkach oddziaływania parcia i ssania wiatru. Metodyka prowadzenia badań oraz wyniki i wnioski z badań.
EN
The range and experimental research program to determine the ultimate and serviceability limit states of the steel rainscreen panels under pressure and sucking wind loading. The research methodology and the conclusions of the research.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.