Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Currently, there is a significant increase in antibiotic resistance and associated multiresistance among microorganisms. An alternative may be the use of essential oils, which possess bactericidal properties. This paper discusses the effect of electromagnetic stimulation of a plant biologically active substance on the degree of their aseptic efficiency with respect to selected strains of Candida krusei ATCC 14243, Enterococcus faecalis ATCC 29212, Paseudomonas aeruginosa ATCC 278596 and Lactobacillus spp. It was found that the application of electromagnetic stimulation of essential oils affects their characteristics of antiseptic effect. Depending on the applied combination of 40 mT and 80 mT magnetic flux density and stimulation time, a progressive or regressive effect of the electromagnetic field was noted. In the case of 40 mT electromagnetic field irrespective of the stimulation time, a significant decrease in the antimicrobial properties of tea tree oil was noted.
PL
Obecnie odnotowywany jest znaczący wzrost antybiotykoodporności oraz związanej z nią wielooporności wśród drobnoustrojów. Alternatywą może być wykorzystanie olejków eterycznych, posiadających właściwości bakteriobójcze. W artykule omówiono wpływ stymulacji elektromagnetycznej substancji biologicznie czynnej roślin na stopień ich efektywności aseptycznej w odniesieniu do wybranych szczepów Candida krusei ATCC 14243, Enterococcus faecalis ATCC 29212, Paseudomonas aeruginosa ATCC 278596 i Lactobacillus spp. Stwierdzono, że zastosowanie stymulacji elektromagnetycznej olejków eterycznych wpływa na ich charakterystykę oddziaływania antyseptycznego. W zależności od zastosowanej kombinacji indukcji pola magnetycznego 40 mT oraz 80 mT i czasu stymulacji odnotowywano progresywne lub regresywne oddziaływanie pola elektromagnetycznego, a w przypadku oddziaływania pola elektromagnetycznego o indukcji 40 mT bez względu na czas stymulacji odnotowano znaczne zmniejszenie właściwości przeciwdrobnoustrojowych olejku z drzewa herbacianego.
PL
Zaproponowano numeryczno-analityczną metodę analizy torów prądowych z przewodami o przekroju kołowym. Metoda wywodzi się ze znanego podejścia, aby sąsiednie przewody traktować jak nitkowe. Polega na obliczeniu kolejnych poprawek uwzględniających skończone rozmiary przewodów. Jak przykład rozpatrzono tory trójfazowe w różnych konfiguracjach. Otrzymane poprawki w gęstości prądu sięgały 10%.
EN
A numerical-analytical method of analyzing current busducts with wires of circular cross-section was proposed. The method is derived from the approach to treat the neighboring wires as current filaments. It consists in calculating subsequent corrections taking into account the finite sizes of wires. Three-phase circuits in various configurations were considered. The obtained corrections in the current density reached up to 10%.
PL
Celem pracy jest wyznaczenie pola magnetycznego w przewodach i ich otoczeniu dla układu dwóch przewodów rurowych. W przypadku torów wielkoprądowych z własnymi prądami fazowymi pole magnetyczne w obszarze zewnętrznym jest sumą wektorową pola magnetycznego własnego i pola wytworzonego przez prądy w sąsiednich przewodach rurowych, z uwzględnieniem pola magnetycznego oddziaływania zwrotnego. W przewodach jest zaś sumą pola magnetycznego własnego z uwzględnieniem zjawiska naskórkowości i pola indukowanego przez pole magnetyczne sąsiednich prądów fazowych. Prąd własny, zgodnie z prawem Ampera, nie wytwarza pola magnetycznego wewnątrz przewodu rurowego, a pole magnetyczne w tym obszarze, pochodzące od prądów w przewodach sąsiednich, może być pominięte.
EN
The aim of this study is to determine the magnetic field in conductors and their surrounding areas for a system of two tubular conductors. For high-current busducts with their own phase currents, the magnetic field in the external area is the vector sum of their own magnetic field and the field generated by currents in the neighbouring tubular conductors, taking into account the reverse reaction magnetic field. In the conductors, on the other hand, we have the sum of their own magnetic field taking into account the skin effect and the field generated by the magnetic field of the neighbouring phase currents. The own current, according the Ampere’s law, does not generate a magnetic field in the tubular conductor and the magnetic field in this area which comes from currents in the neighbouring conductors is negligible.
PL
W artykule przedstawiono matematyczny model wyznaczania strat mocy oraz temperatury w kablu elektroenergetycznym średniego napięcia. Dokładne wyznaczenie mocy wydzielanej w kablu, a w konsekwencji jego temperatury jest bardzo skomplikowane. Straty mocy generowane w kablu uzależnione są od prądu oraz od napięcia. Straty zależne od prądu odnoszą się do ciepła generowanego w elementach przewodzących kabla (żyle roboczej oraz ekranie). Z kolei straty generowane w izolacji kabla związane są z napięciem roboczym. W niniejszym artykule wyznaczono straty mocy i temperaturę kabla pomijając straty występujące w izolacji. Obliczenia wykonano dla przypadku kabla z izolowanym ekranem oraz z prądem powrotnym w ekranie. W obliczeniach uwzględniono zjawisko naskórkowości oraz zbliżenia.
EN
The paper presents a mathematical model for determining power losses and temperature in a medium voltage cable. The exact determination of the power emitted in the cable and, consequently, its temperature is very complicated. The power losses generated in the cable depend on the current and voltage. Current-dependent losses refer to the heat generated in the cable's conductive elements (phase conductor and screen). In turn, the losses generated in the cable insulation are associated with the operating voltage. In the paper the power losses and cable temperature, excluding insulation losses were determined. The calculations were made for a cable with insulated shield and with return current in the shield. The calculations took into account the skin and proximity effects.
PL
W pracy wykazano, że rozkład pola magnetycznego w dwóch zewnętrznych fazach trójfazowego ekranowanego płaskiego toru wielkoprądowego jest niesymetryczny. Składowe tego pola uwzględniają pola magnetyczne oddziaływania zwrotnego prądów wirowych indukowanych w sąsiednich przewodach fazowych w wyniku zjawiska zbliżenia oraz zjawiska naskórkowości. Rozkłady pola w obszarze zewnętrznym faz skrajnych przedstawiono w funkcji parametrów uwzględniających częstotliwość prądu, konduktywność i wymiary poprzeczne przewodów rurowych.
EN
It has been demonstrated in the paper that the magnetic field distribution in two outer conductors of the flat, three-phase single-pole screened, high-current busduct is asymmetric. The components of this field reflect the magnetic field of the reverse reaction fields of the eddy currents induced in the conductors of the adjacent phases as the results of the proximity effect and the skin effect. The field distribution is shown in the outer area of the outer phases as the function of the parameters reflecting the current frequency, the conductivity, and the transverse dimensions of the tubular conductors.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.