Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The deposition-based direct indoor 222Rn and 220Rn progeny measurement techniques are mostly affected by the indoor environmental conditions, such as the ventilation, concentration of condensation nuclei, and reactions with the structure and its furnishings. In this study, a theoretical model of a direct 222Rn and 220Rn progeny monitor based on allyl diglycol carbonate (ADC or CR-39) was established to analyse the factors that influence the detection process by using the parameter sensitivity analysis. The aerosol parameters contributed the highest to the variance, followed by the aerodynamic parameters. With respect to the result of the Spearman’s correlation analysis, the aerosol-related and the room-related parameters are positive, whereas the aerodynamic parameters – which affect the turbulence of indoor deposition – are negative. It means that both the attachment process and the deposition process of 222Rn and 220Rn progenies are important to the performance of the progeny monitor.
EN
The exposure from radon, thoron, and thoron progeny was measured for 45 dwellings in high background radiation area in Takandeang, Indonesia with ambient dose equivalent rate ranging from 0.34 µSv•h-1 to 1.90 µSv•h-1 . The measurement was taken using passive radon and thoron discriminative detector and thoron progeny detector. This measurement was taken from November 2018 to October 2019, and within one month the detector would be replaced with a new detector. The concentrations of radon, thoron, and thoron progeny were calculated as 42–490 Bqm−3 , 20–618 Bqm−3 , and 4–40 Bqm−3 , respectively. The concentrations for outdoor were 49–435 Bqm−3 , 23–457 Bqm−3 , and 4–37 Bqm−3 , respectively, and the annual effective dose was 9.8–28.6 mSv•y-1 . Based on the result of Spearman’s correlations analysis between the indoor radon and thoron concentrations and between the indoor thoron progeny and thoron concentrations, we suggest that exposure to thoron cannot be predicted from exposure to radon, and the equilibrium equivalent thoron concentration has a large uncertainty when it is estimated from thoron concentration assuming a single thoron equilibrium factor.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.