Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
Proactive responding to emerging emergencies by effectively intervening and combating hazardous incidents, which by their nature are qualified for elimination by fire protection units (FPUs), place the area of fire protection within the framework of state security structures. In order to ensure the expected level of efficiency, the state security system makes use of structures and implementation systems that bring together entities carrying out a variety of tasks, in such a way enabling them to function efficiently in their respective fields. One of the most significant elements of the state security structure of this type is the National Firefighting and Rescue System (NFRS). It performs its tasks by carrying out hazard analyses, preventive safeguarding and combating the immediate threats identified in the area by taking up rescue operations. The NFRS, as a system, has been evolving since its inception, both in terms of its structural shape and the tasks it is carrying out. Therefore, the subject of this paper is to consider the evolutionary changes it has undergone, actively adapting to the changing hazard map and improving the model for organising rescue operations. The authors focus on the fact that the levels of rescue action leadership defined in the regulation [6] are interpreted in a variety of ways, and also point out the importance of the function of a commander of a rescue operation (CRO) in the organisation of a rescue or other emergency operation.
PL
Aktywne reagowanie na pojawiające się sytuacje kryzysowe poprzez skuteczne interweniowanie i zwalczanie zdarzeń niebezpiecznych, co do charakteru kwalifikowanych jako wskazane do usuwania przez jednostki ochrony przeciwpożarowej (JOP), umiejscawiają obszar ochrony przeciwpożarowej w ramach struktur bezpieczeństwa państwa. System bezpieczeństwa państwa dla zapewnienia oczekiwanego poziomu efektywności działania wykorzystuje struktury i systemy wykonawcze skupiające podmioty oraz instytucje realizujące różnorodne zadania, umożliwiając tym samym sprawne ich funkcjonowanie w swoich dziedzinach. Jednym z najistotniejszych tego rodzaju elementów struktury bezpieczeństwa państwa jest krajowy system ratowniczo-gaśniczy (KSRG). Realizuje on swoje zadania, prowadząc analizy zagrożeń, prewencyjne zabezpieczanie oraz zwalczanie zidentyfikowanych w danym obszarze bezpośrednich zagrożeń poprzez podejmowanie działań ratowniczych. KSRG jako system od początku powstania ewoluuje zarówno w zakresie kształtu strukturalnego, jak i zadań, które realizuje. Dlatego też przedmiotem opracowania są rozważania na temat ewolucyjnych zmian, jakim podlegał, aktywnie dostosowując się do zmieniającej się mapy zagrożeń oraz doskonaląc model i strukturę organizowania działań ratowniczych. Autorzy skupiają uwagę na fakcie różnorodnego interpretowania zdefiniowanych w rozporządzeniu [6] poziomów kierowania działaniem ratowniczym, a także wskazują na istotę funkcji kierującego działaniem ratowniczym (KDR) w organizacji akcji ratowniczej lub innego działania ratowniczego.
PL
W artykule przedstawiono zarys stanu prawnego, który precyzuje kwestie organizacji akcji i działań ratowniczych, usytuowania prawnego osób wstępujących w funkcję kierującego akcją ratowniczą (KAR) lub innym działaniem ratowniczym (KDR), ukazując obszary wymagające doprecyzowania i uszczegółowienia w celu zapewnienia oczekiwanej jakości realizowanych zadań. Wskazano również sposób precyzowania okresu pełnienia funkcji kierującego działaniem ratowniczym w danym zdarzeniu, ukazując różnicę stanu prawnego pomiędzy dowódcą danego pododdziału a kierującym konkretnym działaniem ratowniczym. Autorzy ukazali miejsca potencjalnego wystąpienia zwiększonego ryzyka decyzyjnego kierujących akcją lub innym działaniem ratowniczym, wynikające z niedookreślonych obszarów regulacji prawnych w rozpatrywanym zakresie, ukazując jednocześnie możliwości wdrożenia rozwiązań dla poszczególnych sytuacji.
EN
The material presents an outline of the applicable legal status intended to help clarify issues related to organisation of rescue actions and activities, legal position of persons acting as commanders of a rescue action or other types of rescue actions, pointing to areas that require clarification and detailing in order to ensure the expected quality of tasks performed. The way of specifying the period of performing the function of a commander of rescue action in a given incident has also been indicated, showing the difference in legal status between the commander of a given subdivision and the commander of a given rescue action. The authors have identified places of potential occurrence of an increased decision-making risk for persons in charge of an action or other types of rescue activities which could arise from insufficient definition of certain areas of legal regulations in the field under consideration, showing at the same time possibilities of implementing solutions for particular situations.
EN
Every day, firefighters put their health and life at risk by saving people and their property not only during fires, but by being always ready during all kinds of unfortunate events. Therefore, they need special personal protective equipment, including protective clothing. The purpose of the study was to compare thermal properties of new (PROTON and SYRIUSZ) and old (US-03) personal protective clothing for firefighters. Measurements of thermal insulation (total, effective and local) were carried out using a full body shape thermal manikin Newton consisting of 34 segments, in which temperature and heat flux were controlled independently. Results of the total thermal insulation of the entire clothing reveal differences between all three models. The lowest values were noticed for the model PROTON with light and shorter jacket and the highest values of thermal insulation for the new model SYRIUSZ, indicating that this model protect the user against heat most effectively. New models of personal protective clothing for firefighters should be recommended for use in everyday work, because they are characterized by better parameters than the previous type of protective clothing, both in terms of thermal protection and mobilit.
PL
Codziennie strażacy narażają swoje zdrowie i życie, ratując ludzi i ich mienie nie tylko podczas pożarów, ale będąc zawsze w gotowości podczas wszelkiego rodzaju nieszczęśliwych zdarzeń. Dlatego też potrzebują oni specjalnych środków ochrony osobistej, w tym odzieży ochronnej. Celem pracy było porównanie właściwości termicznych nowej (PROTON i SYRIUSZ) i starej (US-03) odzieży ochronnej dla strażaków. Pomiary izolacyjności cieplnej (całkowitej, efektywnej i miejscowej) przeprowadzono przy użyciu manekina termicznego Newton o pełnym kształcie ciała, składającego się z 34 segmentów, w którym niezależnie kontrolowano temperaturę i strumień ciepła. Wyniki dotyczące całkowitej izolacji cieplnej całej odzieży wykazują różnice pomiędzy wszystkimi trzema modelami. Najniższe wartości odnotowano dla modelu PROTON z lekką i krótszą kurtką, a najwyższe dla nowego modelu SYRIUSZ, co wskazuje, że ten model najskuteczniej chroni użytkownika przed gorącem. Nowe modele odzieży ochronnej dla strażaków powinny być rekomendowane do stosowania w codziennej pracy, gdyż charakteryzują się lepszymi parametrami niż dotychczasowy typ odzieży ochronnej, zarówno pod względem ochrony termicznej, jak i mobilności.
PL
Rozwój cywilizacyjny niesie za sobą wzrost poziomu zagrożenia oraz złożoności prowadzonych działań ratowniczo-gaśniczych. W celu jak najlepszego zabezpieczenia oraz zachowania BHP na najwyższym poziomie zachodzi konieczność wprowadzanie nowoczesnych rozwiązań umożliwiających jeszcze bardziej efektywne wykonywanie działań przez strażaków-ratowników działających w strefie objętej pożarem. Wielokrotnie strażacy-ratownicy prowadzący działania przy pożarach muszą zabierać ze sobą bardzo dużo dodatkowego sprzętu, który jest im niezbędny m.in. do działań gaśniczych, uzyskiwania dostępu do pomieszczeń, poruszania się w przestrzeni zadymionej i zaciemnionej czy szybkiej lokalizacji osób poszkodowanych i ogniska pożaru. Sprzęt ten choć jest niezbędny powoduje dodatkowe obciążenie dla strażaków pracujących w zagrożonej strefie i może spowodować np. obniżenie czasu reakcji ratownika co może przekładać się na obniżenie poziomu BHP. Fakt ten determinują do poszukiwania nowoczesnych rozwiązań technicznych usprawniających i ułatwiających pracę strażaków działających podczas różnego typu zagrożeń przyczyniających się do podniesienia poziomu bezpieczeństwa oraz zwiększenia efektywności ich działań. W artykule przedstawione zostały główne założenia dotyczące podniesienia poziomu BHPpoprzez zastosowanie innowacyjnego hełmu strażackiego zintegrowanego z obserwacyjnym systemem termowizyjnym, systemem umożliwiającym monitorowanie funkcji życiowych strażaka-ratownika oraz wyjściem do transmisji obrazów i danych do urządzeń zewnętrznych, którego najważniejszym zadaniem będzie ograniczenie wpływu oddziaływania termicznego oraz zagrożeń dynamicznych niesionych przez pożar na strażaka działającego na miejscu akcji.
EN
Civilization development entails an increase in the level of danger and the complexity of rescue and fire-fighting operations. In order to provide the best protection and maintain health and safety at the highest level, it is necessary to introduce modern solutions enabling even more effective performance of actions by firefighters-rescuers operating in the fire zone. Repeatedly firefighters-rescuers conducting actions at fires must take with them a lot of additional equipment, which they need, among others for firefighting, access to rooms, moving in a smoky and darkened space or rapid location of injured persons and fire. Although this equipment is necessary, it causes an additional burden for firefighters working in the danger zone and may, for example, reduce the response time of the rescuer, which may result in the reduction in OHS level. This fact determines the search for modern technical solutions to streamline and facilitate the work of firefighters operating during various types of threat scontributings of threats contributing to increasing the level of safety and increasing the efficiency of their activities. The article presents the main assumptions about raising the level of health and safety through the use of an innovative firefighter helmet integrated with the thermal imaging observation system, a system that allows monitoring the vital functions of the fireman-rescuer and an output for the transmission of images and data to external devices, whose most important task will be to reduce the impact of thermal impact and threats dynamic carried by the fire to the firefighter operating on the spot.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.