Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
W artykule przedstawiono zakres oraz wyniki badań doświadczalnych elementów dwugałęziowych z ceowych lub zetowych kształtowników giętych na zimno o rozpiętości 3 m w schemacie czteropunktowego zginania. Porównano nośności otrzymane z badań doświadczalnych dla przekrojów bazowych i przekrojów z dodatkowymi usztywnieniami na środniku oraz opisano uzyskane formy zniszczenia.
EN
The article presents the course and results of experimental tests conducted on built-up members consisting of two cold-formed channel or zeta sections with a span of 3m in four point bending scheme. The bending resistance obtained from experimental tests for basic sections and sections with additional stiffeners on the web are compared and the observed forms of failure are described.
PL
W artykule przedstawiono przebieg oraz wyniki badań doświadczalnych przeprowadzonych na elementach składających się z dwóch kształtowników giętych na zimno: ceowych lub zetowych długości 1 m. Porównano nośności na ściskanie otrzymane z badań doświadczalnych dla przekrojów bazowych oraz przekrojów z dodatkowymi usztywnieniami na środniku i obliczone wartości nośności przekroju brutto.
EN
The article presents the course and results of experimental tests carried out on elements consisting of two cold-formed sections: channel or zeta sections, 1 m length. The compressive resistance obtained from experimental tests for basic sections and sections with additional stiffeners on the web are compared, as well as the calculated values of the gross section resistance.
EN
This article presents the results of reinforcement cover thickness measurements carried out in several buildings erected in 2022 in Rzeszów. The results of the measurements are presented in two variants depending on the reinforcement cover thickness assumed by the designer: the first variant contains all the results and the second contains results only from places where the designed cover thickness was 25 mm. For both variants, a histogram of the percentage deviation from the design value was determined and mean values, standard deviation, coefficient of variation and maximum values of negative and positive deviation were calculated. The obtained reinforcement cover thickness distributions were used to determine the reliability of a floor slab with a simply supported beam static scheme. Analyses were carried out for 4 slabs differing in span, thickness and selected reinforcement. Using the FORM analytical method, values for the reliability index and probability of failure were determined. The reliability index values obtained were compared with the values required by EC 1990 and ISO 2394. The results obtained did not meet the standard requirements.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.