This paper describes the control modes (boiler follow and turbine follow) commonly used in the operation of thermal power units for automatic active power control of power plants in the Polish National Power System. The benefits and disadvantages of both control modes are discussed. A novel concept is presented for a so-called smooth control of active power, which is based on real-time grouping of several power units to operate as one (in the so-called substitute unit) in both control modes discussed here and with boiler follow as the predominant mode. As demonstrated by initial research and simulation, this novel approach to power unit group control (operated to one bus bar) meets the accuracy of active power control specified by the Transmission System Operator (TSO). The completed simulations and studies also reveal that application of smooth active power control will help reduce the negative effects present in currently applied individual power unit control (with each power unit operated independently in turbine follow). The novel concept will also reduce the number of control processes and eliminate a considerable part of internal disturbances of the substitute unit is eliminated so they will not be transferred to the power system. Furthermore, implementation of the novel concept can help reduce fuel combustion, meet the environmental protection targets by reducing harmful gas and particulate emissions, and extend the operating life of power unit thermal and pressure equipment.
PL
Opisano powszechnie stosowane tryby pracy bloków cieplnych („prowadzący kocioł” i „prowadząca turbina”) wykorzystywane do automatycznej regulacji mocy czynnej w elektrowniach pracujących w KSE. Omówiono zarówno wady, jak i zalety obu trybów pracy. Przedstawiono nowatorską koncepcję tzw. łagodnej regulacji mocy czynnej, opartą na tworzeniu w czasie rzeczywistym grupy złożonej z kilku bloków pracujących jako całość (wieloblok) w omówionych trybach pracy, z przewagą trybu wiodący kocioł. Jak wykazały prace wstępne i symulacje, przedstawione nowatorskie podejście do regulacji grupą bloków (pracującą na wspólne szyny) spełnia wymagania dotyczące dokładności regulacji mocy czynnej wymaganej przez operatora systemu przesyłowego (Polskie Sieci Energetyczne – PSE). Ponadto wykonane analizy i symulacje wskazują, że zastosowanie tej regulacji pozwoli na ograniczenie nega- tywnych skutków występujących przy obecnie stosowanej regulacji indywidualnej dla każdego bloku (bloki pracują indywidualnie w trybie „prowadzącej turbiny”). Proponowane rozwiązanie ograniczy liczbę wymaganych procesów regulacji i zlikwiduje znaczną część zakłóceń bloku, nie przenosząc ich do systemu elektroenergetycznego. Wprowadzenie proponowanego rozwiązania będzie skutkować ograniczeniem ilości spalanego paliwa, zmniejszeniem emisji szkodliwych gazów i pyłów oraz wydłużeniem czasu eksploatacji urządzeń cieplnych i ciśnieniowych bloków.
PL
W artykule opisano system do monitorowania i kontroli jakości automatycznej regulacji oraz diagnostyki pracy bloku energetycznego. Jest to zestaw specjalistycznych programów i algorytmów współpracujących z istniejącymi systemami DCS. Na podstawie pobieranych, rejestrowanych i przetwarzanych danych, prezentowane są wyniki analiz. Pozwalają one na ocenę pracy układów regulacji i bloku w dowolnie zdefiniowanym czasie. Uzyskane informacje dają możliwość wczesnego wykrycia zagrożeń dla stabilnej pracy bloku i podjęcia ewentualnych działań prewencyjnych z odpowiednim wyprzedzeniem. Dzięki temu można uzyskać wydajniejszą, optymalną i niezawodną pracę elektrowni oraz redukcję kosztów eksploatacyjnych. System został z powodzeniem wdrożony na czterech blokach energetycznych w ENEA Wytwarzanie Sp. z o.o.
EN
Presented is a system which purpose is to monitor and check the quality of an automatic control system and to diagnose a power unit operation. The system is based on expert programs and algorithms which cooperate with existing DCS systems. Using the received, registered and processed data, the analysis results are presented. They allow the performance evaluation of control systems and a power unit in a given period. The received information enables operators to take possible preventive actions in advance. Consequently, it is possible to obtain more efficient, optimal and reliable power station operation as well as the exploitation cost reduction. The system has already been successfully implemented for four power units in ENEA Wytwarzanie Sp. z o.o.
PL
Opisano układ do wykrywania zakłóceń swobodnego spływu strumienia paliwa w przykotłowym zasobniku węgla oraz jego praktyczne zastosowanie na obiekcie energetycznym. Zakłócenia te są częstym zjawiskiem występującym w zasobnikach przykotłowych gromadzących węgiel lub mieszaninę węgla i biomasy. Świadczą one o zlepianiu się mas paliwa i tworzeniu przez nie struktur zakłócających pomiar aktualnej zawartości paliwa w zasobniku, prowadząc tym samym do niebezpiecznych zjawisk polegających na niedowęgleniu zespołu młynowego oraz przedmuchiwaniu gorącego powietrza z młyna do komory zasobnika, co z kolei może doprowadzić do zapłonu pyłu węgla i biomasy. Zapłon taki może prowadzić dalej do wybuchu i rozprzestrzenienia się pożaru po całej drodze nawęglania powodując liczne zniszczenia, a nawet wypadki śmiertelne wśród personelu elektrowni. Opisany układ został stworzony w celu wczesnego wykrycia i ostrzegania przed takimi zjawiskami, bez konieczności osobistego wglądu do samego zasobnika.
EN
Presented is a method for detection of disturbances in a free flow of solid fuel stream in a boiler-side coal bunker and its practical use in selected power units. The disturbances are common phenomena in coal bunkers storing either coal or a biomass-coal mixture. They are represented by clustering of fuel masses and formation of structures which impede the measurement of actual fuel level within the coal bunker. This leads to dangerous occurrences associated with deficiency of fuel feed to the mill unit as well as overblow of hot air from the mill unit back to the coal bunker, which may further lead to ignition of coal and biomass dust. The ignition may in turn trigger explosion and the spread of fire over the entire fuel supply line, causing numerous destructions and even fatal accidents among a power plant personnel. The described system was created in order to early detect and warn against such phenomena without the necessity of individual coal bunker inspections.
PL
Opisano uproszczony model pierścieniowo-kulowego młyna węglowego i praktyczne wykorzystanie zamodelowanych w nim sygnałów: temperatury mieszanki pyłowo–powietrznej, który wykorzystano do identyfikacji zapłonów w młynie węglowym oraz sygnału mocy silnika młyna węglowego, który wykorzystano do identyfikacji zaniku paliwa w młynie węglowym, prowadzącego do przegrzania młyna, a następnie do zapłonu. Identyfikacja powyższych zjawisk jest szczególnie istotna podczas procesu współspalania węgla i biomasy, i może przyczynić się do ochrony młyna węglowego przed jego zniszczeniem.
EN
Described is a simplified model of a ring–ball coal mill and the practical use of signals applied to it: the air-dust mixture temperature signal which was used to identify ignitions in the coal mill and the coal mill motor power signal which was used to identify the loss of fuel in the coal mill that leads to overheating of the mill and then ignition. The identification of these phenomena is particularly important during the coal and biomass co-firing process and may contribute to protection of a coal mill.