Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 34

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
PL
W artykule zaprezentowano wyzwania i innowacyjne rozwiązania konstrukcyjne i technologiczne z zakresu budownictwa mostowego na podstawie realizacji firmy GOTOWSKI. Przedstawione zostały konkretne problemy techniczne i wyzwania oraz sposoby ich rozwiązania niejednokrotnie innowacyjnie.
EN
The article presents challenges as well as innovative construction and technological solutions in the scope of bridge construction industry on the basis of the construction project managed by the GOTOWSKI company. It discusses specific technical problems and challenges as well as methods to solve them, which are frequently innovative.
PL
Wieloletnia eksploatacja konstrukcji żelbetowych powoduje różne zużycie elementów konstrukcyjnych w zależności od warunków eksploatacji. Najszybszej degradacji ulegają części zewnętrzne i niezabezpieczone przed skrajnymi wpływami atmosferycznymi. Klasycznym przykładem są żelbetowe balkony budynków wielorodzinnych. Powstałe uszkodzenia prowadzą do utraty nośności wykluczającej dalszą eksploatację płyt. W zależności od stanu betonu, otuliny prętów i samego zbrojenia przywrócenie pierwotnych parametrów użytkowych może być wykonane w różny sposób. W skrajnych przypadkach konieczna jest globalna rekonstrukcja elementów. W artykule przedstawiono stwierdzony stan żelbetowych płyt balkonowych po długim okresie eksploatacji oraz sposób ich odbudowy na przykładzie elementów budynków wielorodzinnych.
EN
Reinforced concrete elements used for many years under various conditions have different degree of destruction. Elements subjected to the direct weather impact and unprotected from it are subjected faster to the general degradation. Reinforced concrete slabs of balconies are the most often met example. Damage arising causes degradation of slabs and do not let to use it more. Depending on the state of concrete, the cover of bars and separately reinforcement restoring original functional parameters can be made in the different way. In extreme cases global reconstruction of elements is necessary. Current state of reinforced concrete slabs of balconies after many years of usage and a way of reconstruction at the example of the elements of multifamily buildings are presented in this paper.
PL
Zbadano wybrane właściwości mechaniczne eksperymentalnego kompozytu stomatologicznego, przed i po jego modyfikacji wybranymi monomerami dimetakrylowymi. Badania uwzględniały ocenę mikrotwardości, średnicowej wytrzymałości na rozciąganie oraz wytrzymałości na zginanie. Kompozyt eksperymentalny charakteryzuje się zadowalającymi właściwościami mechanicznymi, biorąc pod uwagę niewielką zawartość napełniacza, porównywalnymi do niektórych materiałów typu flow. Wprowadzenie monomerów dimetakrylanowych do matrycy kompozytu stomatologicznego powoduje zmiany właściwości mechanicznych tylko w niewielkim stopniu.
EN
An expt. dental composite based on dimethacrylate resins and silanized SiO₂ was modified by addn. of 1,6-hexanediol or diurethane dimethacrylates, photocured (14000 mW/cm2) for 10 or 20 s (1 mm) and studied for micro-hardness, diam., tensile strength and tree-point bending strength. The modified composite showed satisfying mech. properties comparable to some com. flow materials. A slight decrease in mech. properties was however obsd.
PL
Określono wpływ pokrycia warstwą nanokompozytową cementu szkłojonomerowego na ilość oraz dynamikę uwalnianych jonów fluorowych. W przypadku cementu bez powłoki całkowita ilość uwalnianych jonów do roztworu sztucznej śliny wynosiła 0,12-0,28 μg/mm², a materiał z powłoką uwalniał ich 0,001-0,007 μg/mm². Zastosowana warstwa zabezpieczała także cement szkłojonomerowy przed pęknięciami.
EN
Com. dental cement and composite coating were used to make dental fillings. Immediately after prepn. of the fillings, they were placed in an artificial saliva at 36.7°C for 10 days to det. the amt. of released F ions as the quality indicator of the filling. The use of the coating significantly reduced the amt. of released ions.
PL
Badano naprężenia skurczowe generowane podczas fotoutwardzania eksperymentalnego kompozytu stomatologicznego, jak również materiału, do którego dodano 1-10% mas. dimetakrylanu diuretanu lub dimetakrylanu 1,6-heksanodiolu (monomery). Na podstawie uzyskanych wyników stwierdzono, że eksperymentalny kompozyt stomatologiczny oraz jego analog zmodyfikowany dimetakrylanem diuretanu (1 lub 5% mas.) generują niewielkie naprężenia skurczowe, znacznie mniejsze od naprężeń generowanych podczas naświetlania komercyjnych materiałów żywiczych o tradycyjnym składzie osnowy polimerowej.
EN
An expt. dental composite was modified by addn. of diurethane or 1,6-hexanediol dimethacrylate (1-10% by mass), photocured and studied for shrinkage stress during its curing. The stress was significantly smaller in comparison with com. dental composite materials.
EN
This paper synthetically describes results of research conducted in Gdańsk in 2009–2014. The chemical composition of groundwater varies between aquifers. Intermoraine, Miocene and Oligocene aquifers conduct freshwater with a mineralisation of below 600 mg/dm3. These waters preserve natural chemical composition and are characterized by first- and second-class quality. The groundwater of the Cretaceous formation are low-mineralised and represent mainly the HCO3-Na type and, to a smaller extent, to the HCO3-Ca type. High concentrations of fluoride ion are also a specific feature of these waters, reaching even 2 mg/dm in some places. The groundwater composition of the Pleistocene-Holocene aquifer is often altered due to the impact of anthropogenic factors. The performed study has enabled identification of zones of past groundwater pollution. The work was focused on determining the type, extent, concentration and the rate of transport of contaminants. Two zones of polluted water have been identified with different specific substances. Based on the study, activities aimed at reducing the risks and improving an appropriate water management have been undertaken, particularly with regard to the endangered groundwater intakes.
EN
The purpose of this article is to identify the main factors influencing groundwater resources and chemistry in the area of the Gdańsk agglomeration. Two groups of factors were identified: natural – including physico-geographical location, geological structure and hydrogeological conditions and also anthropogenic impact. The studied area is located within a few morphological units: Kashubian Lakeland, Coastal Terrace and Żuławy Gdańskie (Gdańsk Delta Plain). Each of the above unit is characterized by diverse geological structure and lithology of sediments, which in turn affects the diversity of hydrogeological conditions of multiaquifer formations from Pleistocene to the Upper Cretaceous. Groundwater circulation system includes so-called Gdańsk aquifer system. The main recharge area of covers the Kashubian Lakeland. The discharge zone ncludes Coastal Terrace and Żuławy Gdańskie. The aquifers are confined to varying degree which has a direct impact on the rate of contaminants migration. Anthropogenic pollutions are induced by: industry, transport, development and intensive exploitation of groundwater resources. The geogenic risks that affect aquifers in of the Gdańsk agglomeration are: salt water intrusion, brines ascent and fluoride hydrogeochemical anomaly in water from the Upper Cretaceous aquifer in Żulawy Gdańskie.
8
PL
Materiały nanostrukturalne z powodu ich bardzo dobrych mechanicznych i fizycznych właściwości są coraz szerzej wykorzystywane w różnych zastosowaniach. Jedną z możliwości nakładania powłok nanostrukturalnych jest natryskiwanie plazmowe. W pracy przedstawiono badania mikrostruktury i właściwości mechanicznych powłok ZrO2-8Y2O3. Powłoki zostały natryskane z zawiesiny przy użyciu systemu do natryskiwania plazmowego Axial III oraz z proszku Metco 204 NS stosując system Plancer PN120. Powłoka osadzona z proszku posiadała typową lamellarną strukturę, natomiast powłoka natryskana z zawiesiny miała zróżnicowaną mikrostrukturę, w której nanoziarna otoczone były przez całkowicie stopiony materiał powłokowy. Przeprowadzone badania nanoindentacji powłok (twardość i moduł Younga) wykazały zróżnicowanie wartości w zależności od badanego obszaru powłoki (strefa całkowicie lub częściowo stopiona).
EN
Nanostructured materials are of particular scientific interest because of their physical and mechanical properties, which are superior compare to those of conventional materials. They are more widely used in various industrial applications mainly due to decreasing production costs. The work is concerned with a study of microstructure and mechanical properties of ZrO2-8Y2O3 coatings. The coatings were sprayed by means of a SPS (Axial III) and APS (Plancer 120, Metco 204 NS). In opposite to conventional lamellar APS microstructure, SPS coatings showed two-zone microstructure which consisted of nano-particles surrounded by fully molten areas. Nanoindentation tests showed a distribution of the mechanical properties (hardness and Young’s modulus) which is related to the different areas (molten and partially molten) present in the coatings.
PL
Przedstawiono wyniki badań doświadczalnych możliwości uzyskania połączenia materiału kompozytowego z mikrohybrydowymi wypełnieniami kompozytowymi podczas ich naprawy w zależności od sposobu przygotowania powierzchni. Stwierdzono różnice w strukturze i składzie chemicznym powierzchni wypełnień w zależności od sposobu przygotowania ich powierzchni. Na podstawie wyników badań doświadczalnych ustalono warunki dla uzyskania połączenia kompozyt-kompozyt o najwyższej wytrzymałości.
EN
Microhydrid polymer-matrix dental composite was photochemically cured then polished and HF – etched or corundum – sandblasted, optionally silanized and joined to flow type dental composite. The bonds were tested for shear strength. The strength depended on the treated surface quality. The best results were achieved after surface polishing or sand blasting.
PL
Dokonano oceny średnicowej wytrzymałości na rozciąganie, mikrotwardości oraz naprężeń skurczowych generowanych przez materiały kompozytowe o zmodyfikowanej matrycy polimerowej i małym skurczu polimeryzacyjnym w porównaniu z kompozytami o tradycyjnym składzie matrycy polimerowej. Z wyników uzyskanych w badaniach widać jednoznacznie, że oceniane materiały kompozytowe Filtek Bulk Fill oraz SDR generowały małe naprężenia, mniejsze w porównaniu z materiałem X-Flow o tradycyjnym składzie matrycy polimerowej. Materiał SDR charakteryzował się najmniejszą twardością HV1 spośród badanych materiałów. Natomiast materiały Filtek Bulk Fill oraz X-Flow wykazywały zbliżoną twardość. Średnicowa wytrzymałość na rozciąganie w przypadku materiału SDR była mniejsza niż tych materiałów.
EN
Three com. polymer-matrix composites were studied for diam. tensile strength, microhardness and shrinkage stress during light-induced polymerization to compare their applicability in dentistry.
EN
Silver and gold have been used for centuries as antimicrobial agents. The aim of the study was to investigate diametral tensile strength, microhardness, ion release and light transmission of experimental resin composites. Flowable dental composite SDR (Dentsply, United Kingdom) was modified by nanogold, nanosilver and silica addition. The metal ion release, light transmission study, microhardness, Diametral Tensile Strength were evaluated. The experimental nanosilver-containing composites released significant amounts of Al, Si, Sr and Ba ions up to 30 days, and negligible silver ion amounts. Significant Ag ion release occurred in nanosilver- and nanogoldmodified composite. Resin composites modified with nanogold and nanosilver deposited on silica carrier exhibit lower light transmission and have opaque appearance. All experimental composites exhibited higher microhardness in comparison to non-modified resin composites. Diametral Tensile Strength of the experimental composites was comparable to the control group.
PL
W celu uzyskania połączenia materiałów kompozytowych podczas naprawy wypełnień jest konieczne odpowiednie przygotowanie ich powierzchni, umożliwiające wytworzenie tak mikromechanicznego, jak i chemicznego połączenia. Starzenie się matrycy polimerowej z upływem czasu stwarza ograniczone możliwości uzyskania połączeń chemicznych. Rozwiązaniem problemu może być zastosowanie obróbki tribochemicznej w połączeniu z silanizacją powierzchni, zapewniającej oprócz mechanicznego także chemiczne połączenia materiałów kompozytowych. Celem pracy była ocena wpływu obróbki tribochemicznej na wytrzymałość połączenia materiałów kompozytowych z wcześniej spolimeryzowanym kompozytem. Badania przeprowadzono na próbkach mikrohybrydowego materiału kompozytowego Spectrum TPH3/Dentsply, poddanych procesowi starzenia obejmującego przechowywanie w atmosferze powietrza przez 24 miesiące. Następnie próbki szlifowano na mokro papierami ściernymi 500C i po osuszeniu powietrzem poddano obróbce tribochemicznej. Obróbka obejmowała wstępne piaskowanie korundem 110 μm (Rocatec Pre) i końcowe korundem 110 μm modyfikowanym krzemionką (Rocatec Plus), a następnie aplikację silanu. Próbki grup kontrolnych piaskowano korundem 110 μm oraz 50 μm i silanizowano. Na powierzchnię obydwu grup aplikowano i polimeryzowano system wiążący oraz materiał kompozytowy. Wytrzymałość połączenia materiałów badano w próbie ścinania za pomocą urządzenia Zwick Z020Zwick-Rooel. Dodatkowo w badaniach mikroskopowych (SEM-EDS) oceniono strukturę powierzchni próbek kompozytu i skład chemiczny. Zastosowanie obróbki tribochemicznej umożliwia rozwinięcie powierzchni i zapewnia uzyskanie wytrzymałości połączenia kompozyt-kompozyt porównywalnej z obróbką strumieniowo-ścierną korundem 110 μm bądź 50 μm.
EN
The appropriate preparation of the composite surface can guarantee micromechanical and chemical bond between dental composites during repair of resin restoration. The polymer matrix aging leads to lower capability of creating chemical bond. The application of tribochemical process, together with silanization, that provide both chemical and micromechanical bond between dental composites, might be an option. The aim of this study was to evaluate the influence of tribochemical process on the bond strength between dental composites and previously polymerized composite. Research was conducted on speciments of microhybrid dental composite Spectrum TPH3/Dentsply, that had undergone aging process (24 months storage in air). Samples were subsequently wet-polished with 500C abrasive paper, dried with air and treated with tribochemical process. Process included initial sandblasting with 110 μm corundum (Rocatec Pre) and final sandblasting with 110 μm silica-modified corundum (Rocatec Plus) and silane application. Samples from control groups were sandblasted with 110 μm and 50 μm corundum and silanized. All samples were covered with bonding system and dental composite, that were polymerized. Bond strength was evaluated in shear test, using Zwick Z005/Zwizk-Roel testing device. Surface structure and chemical composition was evaluated using SEM-EDS. The application of tribochemical process allows for surface development and provides composite-composite bond comparable to sandblasting with 50 μm or 110 μm corundum.
PL
Uzyskanie klinicznie trwałych połączeń materiałów kompozytowych z wypełnieniami kompozytowymi podczas ich naprawy wymaga odpowiedniego przygotowania powierzchni wypełnień. Różnice w składzie chemicznym, ilości wypełniacza i mikrostrukturze materiałów kompozytowych mogą być przyczyną różnej podatności na adhezyjne przygotowanie powierzchni wypełnień. Celem pracy była ocena wpływu sposobu przygotowania powierzchni wypełnień kompozytowych na strukturę ich powierzchni oraz wytrzymałość połączenia z materiałami kompozytowymi w zależności od rodzaju naprawianego materiału kompozytowego. Próbki spolimeryzowanych kompozytów (mikrofilowego i mikrohybrydowego) szlifowano, trawiono 9,5% kwasem fluorowodorowym bądź piaskowano. Za pomocą SEM oceniono strukturę powierzchni tak przygotowanych próbek. Zbadano także wytrzymałość połączenia kompozytów (mikrofilowego i mikrohybrydowego) z materiałem kompozytowym typu flow przy różnych sposobach przygotowania powierzchni i silanizacji. Materiały kompozytowe po odpowiednim przygotowaniu powierzchni łączono systemem wiążącym. Po 24 godzinach badano wytrzymałość uzyskanego połączenia w porównaniu z próbkami, w których materiał kompozytowy łączono ze szlifowanym kompozytem systemem wiążącym. Wytrzymałość połączenia oceniano w próbie ścinania w urządzeniu testującym Zwick Z005. Najmniejszą wytrzymałość połączenia kompozyt-kompozyt uzyskano po szlifowaniu powierzchni oraz trawieniu kwasem HF i silanizacji. Szlifowanie powierzchni i silanizacja oraz piaskowanie powierzchni i silanizacja zapewniały większą wytrzymałość połączenia kompozyt-kompozyt za pomocą systemu wiążącego.
EN
Obtaining clinically durable bond of dental composites to previously applied composite restorations, for repair purposes, needs the proper preparation of restoration surface. Differences in chemical composition, proportion of filler and microstructure of dental composites might be the reason for various susceptibility to adhesive preparation of composite surface. Conflicting opinion on efficiency of different methods of bonding composites convinced us to compare the durability of composite-composite bond, acquired with use of different surface preparation techniques. The aim of this research was to evaluate the influence of composite surface conditioning method on surface structure and durability of bond to composite material depending on type of repaired material. Samples of polymerized materials (microfill and microhybrid dental composite) were wet polished and treated with 9.5% HF or air-abraded. Surface structure of samples were evaluated in SEM. Durability of bond between samples of material (microfill and microhybrid) and flowable composite was also studied. Surface of composite material (microfill and microhybrid) after conditioning (HF etching and air-abrasion), application of silan and bonding system, was bonded to flowable composite. After 24 hours of storage, durability of bond between materials was measured and compared to samples, in which flowable composite was bonded to polished composites with bonding system. Bond durability was evaluated in shear test in Zwick Z005 testing device. The lowest durability of bond was acquired after polishing, treatment with HF acid and silanization. Silanization after polishing and silanization after air-abrasion provided sigificantly higher durability of composite-composite bond.
PL
Przyczyną niepowodzeń klinicznych przy wykonywaniu wypełnień kompozytowych są głównie naprężenia skurczowe polimeryzującego materiału. Jedną z metod ograniczenia naprężeń indukowanych na granicy wypełnień i tkanek zębów są techniki warstwowej polimeryzacji wypełnień. W ostatnich latach zostały wprowadzone materiały typu bulkfill, kompozyty o zmienionych właściwościach, zmodyfikowanej transmisji światła i zmienionym układzie katalitycznym, przystosowane do wypełniania ubytku w grubych, 4 mm warstwach materiału. Przy braku informacji o ich właściwościach zachodzi konieczność oceny naprężeń skurczowych tych materiałów w zależności od sposobu ich aplikacji, co pozwoli na rzeczywistą ocenę wartości lansowanej ostatnio techniki wypełniania ubytków bulkfill w porównaniu z tradycyjnymi, warstwowymi technikami aplikacji i polimeryzacji materiałów. W pracy określono wielkości naprężeń skurczowych indukowanych podczas polimeryzacji przez materiały kompozytowe typu bulkfill w porównaniu z materiałami tradycyjnymi w zależności od sposobu wypełniania ubytku (technika bulkfill, polimeryzacja warstwowa z wykorzystaniem warstw poziomych i skośnych). Przeprowadzono elastooptyczne pomiary wielkości naprężeń zredukowanych w badaniach na płytkach z optycznie czułej żywicy epoksydowej oraz analizę stanu naprężeń wokół wykonanych wypełnień. Pomiary przeprowadzono za pomocą polaryskopu kołowego FL200/Gunt, wykorzystując do analizy program komputerowy ACD-System oraz metody analizy matematycznej. Materiały o tradycyjnym składzie matrycy polimerowej indukowały większe naprężenia skurczowe od materiałów typu bulkfill i obserwowano istotne zmniejszanie się naprężeń dla aplikacji warstwowej poziomej (średnie naprężenia) i skośnej (najmniejsze naprężenia). Materiały typu bulkfill indukowały mniej sze naprężenia, a dla materiału Tetric Evo Ceram Bulk Fill nie wykazano wpływu sposobu aplikacji na wielkość naprężeń skurczowych.
EN
The reason for clinical failure after appllication of composite restorations is, at most, the phenomenon of shrinkage stresses, occuring during polymerization of dental composites. Among the methods of reducing the stresses, induced on the margin of restoration and tooth hard tissues, are multilayer polymerization techniques. However, in recent years new bulkfill dental composites, with changed properties, different cathalitic system and modified light transmission, adjusted to fill cavities in layers up to 4 mm thick, were released. With the lack of information on their properties, evaluation of shrinkage stresses due to the methods of application is necessary. It should provide the assessment of the real value of bulkfill application method in comparison to multilayer application and polymerization techniques. In this research, quantities of shrinkage stresses of various bulkfill dental composites in comparison to traditional composites during polymerization were measured in dependance to application method (bulkfill, multilayer technique including horizontal and oblique layers). In photoelastic research with use ofplates made of photoelastic sensitive epoxy resin, measurements of reduced stresses quantities and analysis of stresses condition around restorations were made. Measurements were conducted with use of FL200/Gunt circular polariscope, ACD-System software for computer analysis and various methods of mathematical analysis. Materials of traditional matrix compound induced higher stresses than bulkfill dental composites, significantly lower stresses for horizontal layers application method (average stresses) and oblique layers application method (lowest stresses) were also obseryed. Bulkfill dental composites induced lower stresses, for Tetric Evo Ceram Bulk Fill composite no impact of application method on shrinkage stresses was showed.
PL
Z klinicznego punktu widzenia podczas wykonywania wypełnień kompozytowych najistotniejsze jest maksymalne ograniczenie naprężeń skurczowych generowanych na granicy wypełnienie-tkanki zębów, są one bowiem zasadniczą przyczyną powikłań klinicznych. W ostatnich latach dla ograniczenia naprężeń generowanych na granicy wypełnień i twardych tkanek zębów proponuje się wykorzystanie nowo opracowanych materiałów kompozytowych o zmienionym składzie matrycy polimerowej, wskazywanych jako kompozyty o małym skurczu polimeryzacyjnym. O wielkości powstałych naprężeń decyduje jednak nie tylko skurcz polimeryzacyjny, ale także sprężystość materiału kompozytowego. Brak jakichkolwiek badań oceniających naprężenia skurczowe generowane przez te materiały skłonił do podjęcia badań w tym zakresie. W pracy określono wielkości naprężeń skurczowych generowanych podczas polimeryzacji przez różne materiały kompozytowe o małym skurczu polimeryzacyjnym w porównaniu z kompozytami tradycyjnymi. W badaniach elastooptycznych na płytkach z optycznie czułej żywicy epoksydowej przeprowadzono pomiary wielkości naprężeń zredukowanych oraz analizę stanu naprężeń wokół wykonanych wypełnień. Pomiary przeprowadzono za pomocą polaryskopu kołowego FL200/Gunt, wykorzystując do analizy program komputerowy ACD-System oraz metody analizy matematycznej. W badaniach uzyskano różne wartości naprężeń generowanych przez poszczególne materiały kompozytowe. Oceniane materiały kompozytowe różniły się istotnie pod względem naprężeń skurczowych generowanych podczas polimeryzacji. Najmniejsze naprężenia generowały materiały o małym skurczu polimeryzacyjnym, aczkolwiek część materiałów o tradycyjnym składzie fazy polimerowej generowało stosunkowo niskie naprężenia.
EN
From clinical point of view, maximal reduction of shrinkage stresses, generated on the material-hard tissues margin, is the key factor in avoiding clinical complications during cavity restoration with use of dental composites. In recent years, use of new type of low polymerization shrinkage dental composites including modified matrix was suggested to decrease stresses between material and tissues. Quantity of stresses is determined not only by the polymerization shrinkage, but also by flexibility of the composite. Lack of research evaluating shrinkage stresses generated by the materials mentioned has led to the decision on conducting study on this matter. In the research, quantities of shrinkage stresses of various low-shrinkage dental composites in comparison to traditional composites during polymerization were measured. In photo-elastic research with use of plates made of photoelastic sensitive epoxy resin, measurements of reduced stresses quantities and analysis of stresses condition around restorations were made. Measurements were conducted with use of FL200/Gunt circular polariscope, ACD-System software for computer analysis and various methods of mathematical analysis. In research, various values of stresses generated by certain composites were acquired. Evaluated composites varied significantly in shrinkage stresses generated during polymerization. The lowest stresses were observed in composites of low polymerization shrinkage, but some materials of classic composition of matrix also generated low stresses.
PL
Autorzy artykułu podejmują próbę omówienia zaledwie kilku wybranych problemów występujących podczas przyłączenia podmiotów do sieci, z którymi spotyka się w swojej działalności Prezes Urzędu Regulacji Energetyki (Prezes URE). Jednym z takich zagadnień jest wpływ decyzji o lokalizacji inwestycji celu publicznego na decyzję rozstrzygającą spór z art. 8 ust. 1 ustawy z 10 kwietnia 1997 r. − Prawo energetyczne1).
PL
Ocenę jakości wód podziemnych Gdańska i Sopotu wykonano na podstawie szeroko zakrojonych badań, zarówno pod względem liczebności, jak i zakresu oznaczeń. Przeanalizowano wpływ terenów zurbanizowanych i poprzemysłowych, znajdujących się w strefach dopływu wód do części ujęć oraz obecny stopień oddziaływania słonych wód morskich na warstwy wodonośne. Przy pomocy analizy hydrodynamiki wyznaczono kierunki przepływu wód podziemnych, ze szczególnym wskazaniem kierunków migracji wód zanieczyszczonych.
EN
Groundwater quality assessment for Gdansk and Sopot was based on extensive research, both in number and scope. The stress of urban and post-industrial land, located on the part of water intakes, were considered as well as the influence of salty sea water on aquifer. The analysis of hydrodynamics revealed groundwater flow direction, that let determine the contaminated groundwater flow destination.
PL
Dokonano analizy wybranych właściwości elementów wykonanych ze stopu Zenotec™ NP metodą frezowania oraz porównania odporności korozyjnej elementów bez i po procesach pasywacji elektrochemicznej. Do badań użyto elementów ze stopu CoCr Zenotec NP/Wieland, frezowanych w urządzeniu Zenotec/Wieland. Określono ich mikrostrukturę i skład chemiczny. Morfologię stopów scharakteryzowano metodą skaningowej mikroskopii elektronowej z użyciem EDS. Badania obejmowały również ocenę odporności na korozję elektrochemiczną przez analizę krzywych polaryzacji anodowej. Zbadano także wpływ pasywacji elektrochemicznej, w fizjologicznym roztworze NaCl, powierzchni stopu na jego właściwości korozyjne. Wyniki badań wskazują na wysoki stopień jednorodności składu chemicznego wytwarzanych elementów, a co za tym idzie również dobre właściwości antykorozyjne, natomiast badania elektrochemiczne metodą polaryzacji potencjodynamicznej wykazały większą odporność korozyjną elementów poddanych procesowi modyfikacji powierzchni.
EN
Profile-milled, blast sanded or founded com. CoCr and CoCrMo alloy prosthetic elements compn. and electrochem. corrosion resistance optionally after passivation in 0.9% NaCl soln. at 10–40 mV. The profile-milled elements showed the highest homogeneity of the chem. compn. The passivation at 10 mV resulted in an increased corrosion resistance of the elements.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.