EN
Partial discharges (PD) are influencing electrical insulating systems of high voltage electrical devices. Typically, in laboratory and diagnostics AC tests focused on measuring and analysis of PD, a pure sinusoidal voltage waveform is assumed. However, in practice the spectral content of the working voltage is rarely so ideal and additional spectral components have a significant impact on the discharge behaviour in electrical insulation systems. In this paper the influence of voltage harmonics on PD behaviour and phase-resolved PD patterns evolution is analysed. The presented experiments were conducted on a specimen representing a gaseous inclusion embedded in electrical insulation. The experimental results showed that various harmonic compositions superimposed on the fundamental sinusoidal waveform have a significant impact on PD intensity and maximum charge. In consequence, the derived patterns of PD phase, and magnitude distributions are distorted, and statistical parameters calculated on their basis are changed. In certain environments, neglecting harmonic content in the testing voltage may lead to a misleading interpretation and assessment of PD severity.
PL
Omówiono referaty poświęcone zagadnieniom oceny i monitorowania rozwoju nowych materiałów elektrotechnicznych i nowoczesnych technik badawczych ich właściwości eksploatacyjnych. Problemy te dotyczą zarówno materiałów izolacyjnych jak i przewodzących. Przedstawiono także nowoczesne techniki diagnostyczne oraz metody analizy i interpretacji wyników badań procesów przemian w ich strukturach przy narażeniach elektrycznych, cieplnych i środowiskowych. Szczególnym zainteresowaniem objęte są nowe techniki badawcze mające zastosowanie do oceny stanu obiektów w ­elektroenergetyce. Tematami preferowanymi referatów były: kompaktowe systemy izolacyjne (AC i DC), nowe materiały oraz niestandardowe narażenia i nowe techniki badawcze.
EN
Discussed are papers dedicated to problems of assessment and monitoring of the development of new electrotechnical materials and modern research techniques concerning their operational properties. One must remeber that these problems concern both insulation and conductive materials. Presented are also modern diagnostic techniques as well as analysis and interpretation methods concerning results of research on processes related to changes in these materials when exposed to electrical, thermal and environmental hazards. Particular attention is paid to new research techniques applied for assessment of technical condition of power industry facilities. Preferential subjects of the papers were AC and DC compact insulation systems, new materials as well as non-standard hazards and new diagnostic techniques.
3
PL
Wartości szczytowe przepięć pojawiających się na zaciskach transformatorów są ograniczane przez stosowanie beziskiernikowych ograniczników przepięć do wartości wynikających z koordynacji izolacji. Wartości przepięć docierających do zacisków transformatora są jednak większe od wartości maksymalnych napięć roboczych. Przepięcia są przenoszone przez uzwojenia transformatorów i propagują się wzdłuż linii zasilających. Zjawiska przejściowe w uzwojeniach i liniach mają wpływ na przebiegi i wartości maksymalne przepięć. W artykule przedstawiono analizę przepięć przenoszonych przez transformator i propagujących się w układzie doświadczalnym modelującym typowy fragment sieci rozdzielczej. Wyznaczono wartości maksymalne oraz częstotliwości rezonansowe przepięć generowanych przez udar napięciowy prostokątny o stromym czole i sygnał sinusoidalny w szerokim zakresie częstotliwości.
EN
The crest values of overvoltages appearing at the transformer terminals are limited by surge arresters to the level determined by the insulation coordination. Those values are much higher than maximum nominal voltage. Overvoltages are transferred through transformers and propagate along supplying lines. Transient phenomena in transformers and lines have influence on shapes and maximal values of overvoltages. Analysis of overvoltages transferred through transformers and propagated in experimental system modeling typical part of electrical distribution network are presented in the paper. Wartości maksymalne and resonant frequency overvoltages generated by surge voltage with short time to the crest nad sinusoidal signal in wide frequency have been determined
4
Content available remote Narażenia przepięciowe układów izolacyjnych transformatorów rozdzielczych
PL
Spośród narażeń eksploatacyjnych transformatorów przepięcia mają decydujący wpływ na optymalizację wytrzymałości elektrycznej układów izolacyjnych i zwiększenie niezawodności pracy transformatorów wpływające na ciągłość dostarczania energii elektrycznej. W artykule przedstawiono analizę narażeń przepięciowych układów izolacyjnych, podczas oddziaływania udarów napięciowych o zróżnicowanych przebiegach, odzwierciedlających przepięcia powstające w warunkach eksploatacji transformatorów rozdzielczych w układach elektroenergetycznych oraz podczas prób napięciowych. Podstawą analizy były wyniki badań przepięć narażających układy izolacyjne transformatorów zawierających uzwojenia o zróżnicowanych rozwiązaniach konstrukcyjnych i parametrach elektrycznych.
EN
From amang exploitation impacts of transformers the overvoltages have decisive influence on optimization of electric strength of insulation systems and guarantee reliability for work of transformers which have great meaning to improvement of continuity delivery for electrical energy. Analysis of overvoltage impacts on insulation systems during influence of voltage strokes with different shapes where model overvoltages generated during exploitation conditions of distribution transformers in electrical power systems and during voltage tests is presented in the paper. As a basis of the analysis are results of investigations for overvoltages in insulation systems of transformer windings with different constructions and electrical parameters.
PL
Transformatory w warunkach eksploatacji są narażone na oddziaływanie przepięć o zróżnicowanych przebiegach. Narażenia przepięciowe układów izolacyjnych wewnętrznych są zależne od reakcji transformatora na przepięcia powstające w układach elektroenergetycznych. Doskonalenie konstrukcji układów izolacyjnych oraz zwiększenie niezawodności pracy wymaga analizy tych narażeń. W artykule przedstawiono narażenia przepięciowe układów izolacyjnych transformatorów podczas prób napięciem udarowym oraz w warunkach eksploatacji. Podstawą analizy były wyniki rejestracji przepięć wewnętrznych w uzwojeniach transformatora podczas oddziaływania napięć udarowych piorunowych pełnych i uciętych oraz udarów modelujących przepięcia powstające w układach elektroenergetycznych.
EN
Transformers in exploitation conditions are impact to action overvoltagrs with different courses. Influence of overvoltages on internal insulation systems depend from reaction of transformer to overvoltages generated in electrical power systems. Development of construction for insulation systems and increase of reliability of work need analysis of such impacts. Analysis of overvoltage impacts on insulation systems during voltage tests and in exploitation conditions is presented in the paper. As a basis of the analysis are results of investigations for overvoltages in insulation systems of transformer windings during action full and chopped lightning voltage strokes and voltage strokes modeling overvoltages generated in electrical power systems.
PL
W niniejszym artykule zaprezentowano sposób modelowania łuku elektrycznego za pomocą specjalistycznego programu przeznaczonego do przeprowadzania analiz stanów przejściowych w systemach elektroenergetycznych (program EMTP-ATP). Celem przedstawianych symulacji jest określenie wartości przepięć oraz czasu łukowego w trakcie trwania operacji łączeniowych wykonywanych przy użyciu rozpowszechnionych styczników elektromechanicznych. Zaprezentowano porównanie przebiegów symulacyjnych oraz pomiarowych napięcia powrotnego zmierzonego pomiędzy stykami stycznika, oraz przebiegi przerywanego prądu. Wykazano, że symulacje są efektywnym i praktycznym narzędziem w analizie łączeniowych stanów przejściowych.
EN
This paper presents the electric arc modelling and its implementation in specialized simulation software for transient analyses during switching conditions in LV circuits (EMTP-ATP software). Simulations can be very useful to estimate overvoltages and arcing times during switching operations performed by means of electromechanical relays, which are commonly used in automation. Comparison of measured and calculated Transient Recovery Voltage (TRV) and current waveforms is shown in this article. It is clearly indicated that severe overvoltages may arise upon electromechanical relays operation, and that the simulation is an efficient tool when analyzing such phenomena.
EN
Modern electric motors of small power are often supplied with electronic power converters producing PWM voltages. For this reason, it is necessary to study the properties of winding insulation of these motors using pulse voltages with variable rise times and switching frequencies. The paper describes the results of investigations of magnet wires insulation with different diameters in a standardized model samples, for the assessment of their resistance to exposure on pulse voltages.
PL
Współczesne silniki elektryczne małych mocy są często zasilane z przekształtników energoelektronicznych wytwarzających napięcia typu PWM. Z tego powodu zachodzi konieczność badania właściwości izolacji uzwojeń tych silników z zastosowaniem napięć impulsowych o zmiennych czasach narastania oraz częstotliwościach kluczowania. Artykuł opisuje wyniki badania izolacji drutów nawojowych o różnych średnicach w standaryzowanych próbkach modelowych, dla oceny ich odporności na narażenia napięciami impulsowymi.
PL
Przepięcia piorunowe stanowią realne zagrożenie dla izolacji transformatorów energetycznych oraz ograniczenie ich niezawodności eksploatacyjnej. Bezpośrednie skutki ekonomiczne tych zjawisk wskazują na potrzebę rozpoznania rzeczywistych warunków oddziaływania przepięć na układy izolacyjne oraz analizę ich wpływu na pracę transformatorów. Przepięcia piorunowe w uzwojeniach transformatorów stanowią szczególnie ważne zagadnienie. W pracy przedstawiono wyniki analizy rozkładu przepięć piorunowych w eksperymentalnym uzwojeniu warstwowym transformatora energetycznego, wyposażonym w dwa ekrany elektrostatyczne. Analizowano wpływ ekranów na wartości maksymalne przepięć oraz ich przebiegi czasowe. Wyniki symulacji rozkładów początkowych napięcia w uzwojeniu warstwowym ekranowanym oraz nieekranowanym zostały również przedstawione w artykule.
EN
Surge overvoltages pose a threat to a power transformer insulation system and may lead to the transformer failure. Internal overvoltages in the windings are particularly dangerous due to their direct impact on condition of the winding insulation system. The analysis of surge overvoltages distribution in an experimental layer type winding of power transformer is presented in this paper. The influence of electrostatic shields on magnitude and waveforms of surge voltages in the winding is analyzed based on measurement results. The simulation results of initial voltage distributions for shielded and unshielded winding are also presented.
PL
Analiza narażeń przepięciowych układów izolacyjnych urządzeń elektrycznych powinna obejmować także przepięcia przenoszone przez transformatory. Szczególne znaczenie ma analiza przepięć przenoszonych przez transformatory rozdzielcze do sieci niskiego napięcia z powodu zwiększającej się liczby urządzeń elektrycznych i elektronicznych o małej odporności na oddziaływanie przepięć. Narażenia przepięciowe urządzeń elektrycznych są zależne od wartości maksymalnych i przebiegów przepięć oraz warunków propagacji przepięć w sieciach elektrycznych oraz ochrony przepięciowej. W artykule przedstawiono analizę propagacji przepięć przenoszonych przez transformator rozdzielczy w typowych fragmentach sieci elektrycznych niskiego napięcia. Podstawą analizy były symulacje przepięć wykonane przy zastosowaniu programu Electromagnetic Transients Program-Alternative Transients Program (EMTP-ATP). Do modelowania transformatora zastosowano model wysokoczęstotliwościowy, opracowany na podstawie wyników pomiarów funkcji przenoszenia.
EN
Analysis of overvoltage impacts of insulation systems for electrical devices should include also overvoltages transferred through transformers. Special mean have analysis of overvoltages propagated through distribution transformers to low voltage networks because number of electrical devices and electronic equipment with smal overvoltage hardnes is more and more large. Overvoltages impact on electrical devices are depended on maximal values and time courses of overvoltages and condition of overvoltage propagation in eletrical networks and overvoltage protection. Analysis of propagation for overvoltages transferred through distribution transformers in typical part of low voltage networks is presented in the paper. As a basis of the analysis were results of simulations done by use of Electromagnetic Transients Program-Alternative Transients Program (EMTP-ATP). Distribution transformer was modeled by use of high frequency model of transformer prepared on basis of measurement results of transfer functions.
PL
Analiza narażeń przepięciowych układów izolacyjnych urządzeń elektrycznych powinna obejmować także przepięcia przenoszone przez transformatory. Szczególne znaczenie ma analiza przepięć przenoszonych przez transformatory rozdzielcze do sieci niskiego napięcia z powodu zwiększającej się liczby urządzeń elektrycznych i elektronicznych o małej odporności na oddziaływanie przepięć. Narażenia przepięciowe urządzeń elektrycznych są zależne od wartości maksymalnych i przebiegów przepięć oraz warunków propagacji przepięć w sieciach elektrycznych oraz ochrony przepięciowej. W artykule przedstawiono analizę propagacji przepięć przenoszonych przez transformator rozdzielczy w typowych fragmentach sieci elektrycznych niskiego napięcia. Podstawą analizy były symulacje przepięć wykonane przy zastosowaniu programu Electromagnetic Transients Program-Alternative Transients Program (EMTP-ATP). Do modelowania transformatora zastosowano model wysokoczęstotliwościowy, opracowany na podstawie wyników pomiarów funkcji przenoszenia.
EN
Analysis of overvoltage impacts of insulation systems for electrical devices should include also overvoltages transferred through transformers. Special mean have analysis of overvoltages propagated through distribution transformers to low voltage networks because number of electrical devices and electronic equipment with smal overvoltage hardnes is more and more large. Overvoltages impact on electrical devices are depended on maximal values and time courses of overvoltages and condition of overvoltage propagation in eletrical networks and overvoltage protection. Analysis of propagation for overvoltages transferred through distribution transformers in typical part of low voltage networks is presented in the paper. As a basis of the analysis were results of simulations done by use of Electromagnetic Transients Program-Alternative Transients Program (EMTP-ATP). Distribution transformer was modeled by use of high frequency model of transformer prepared on basis of measurement results of transfer functions.
PL
Omówiono referaty poświęcone zagadnieniom oceny i monitorowania rozwoju nowych materiałów elektrotechnicznych i nowoczesnych technik badawczych ich właściwości eksploatacyjnych. Problemy te dotyczą zarówno materiałów izolacyjnych jak i przewodzących. Oprócz właściwości materiałów elektrotechnicznych omówiono problemy dotyczące ładunku przestrzennego i powierzchniowego oraz rozkładu potencjału i testów narażeń eksploatacyjnych. Przedstawiono także nowoczesne techniki badawcze i narzędzia diagnostyczne oraz metody analizy i interpretacji wyników badań procesów przemian w ich strukturach przy narażeniach elektrycznych, cieplnych, środowiskowych i innych. Szczególnym zainteresowaniem objęte są nowe techniki badawcze mające zastosowanie do oceny stanu obiektów w elektroenergetyce. Wiele miejsca poświęcono również właściwościom i zastosowaniom nowych materiałów, w tym nadprzewodzących, przyjaznych środowisku, a także materiałom do kształtowania pola elektrycznego.
EN
Discussed were lectures dedicated to the problems of assessment and monitoring of new electrotechnical materials and modern research techniques of their operating properties, not forgetting about the fact that the problems concern both insulating and conducting materials. Apart from the properties of electrotechnical materials there were discussed problems referring to space and surface charges as well as to the potential distribution and operational hazards’ tests. Presented were also modern research techniques and diagnostic tools as well as the analysing and interpretation methods of testing results of transformation processes occurring in structures of electrotechnical materials exposed to electrical, heat, environmental and other hazards. Particular attention was paid to new research techniques used for condition assessment of the power industry facilities. Substantial space was also given to properties and applications of new materials including the environment-friendly superconductive ones and the ones for electric field shaping.
EN
Lightning overvoltages occurring in electrical power systems are especially dangerous for devices installed in network. Lightning transients may cause damages of devices installed in power system. Therefore, analysis of lightning overvoltages in electrical power systems is important to ensure reliability of power supply. For this purpose, development of mathematical models is necessary, however mathematical complexity can lead to slightly different results. In this paper, both various overhead transmission lines models as well as exemplary insulation coordination analysis performed in HV power system have been presented. Simulation results performed for various models of overhead lines implemented in EMTP/ATP software have been presented and compared in this paper.
PL
Przepięcia atmosferyczne są szczególnie niebezpiecznie dla urządzeń zainstalowanych w sieciach elektroenergetycznych. Z tego powodu, zdeterminowanie poziomu przewidywanych przepięć atmosferycznych jest istotne z punktu widzenia koordynacji izolacji. Do tego celu, konieczne jest opracowanie modeli matematycznych poszczególnych elementów sieci elektroenergetycznej. Jednakże, w zależności od sposobu modelowania, wyniki symulacji mogą się różnić pomiędzy sobą. Artykuł zawiera zestawienie trzech modeli matematycznych linii przesyłowych, mogących posłużyć do przeprowadzania symulacji przepięć atmosferycznych. W artykule przedstawiono wyniki symulacji przepięć atmosferycznych przeprowadzonych dla przykładowego systemu z wykorzystaniem różnych modeli linii przesyłowych.
13
Content available remote Symulacje przepięć przenoszonych przez transformatory energetyczne
PL
Przepięcia przenoszone przez uzwojenia transformatorów energetycznych stanowią narażenia układów izolacyjnych transformatorów oraz urządzeń zasilanych. Przepięcia są przenoszone przez transformatory w wyniku zjawisk przejściowych w uzwojeniach stanowiących złożone układy nieliniowe pomiędzy którymi istnieją silne sprzężenia elektromagnetyczne. Symulacje przepięć przenoszonych przez transformatory wymagają stosowania modeli transformatorów, odzwierciedlających zjawiska występujące w warunkach propagacji przepięć między uzwojeniami. W artykule przedstawiono wyniki symulacji przepięć przenoszonych przez uzwojenia transformatora wykonane przy zastosowaniu modeli transformatorów istniejących w programie EMTP/ATPDraw oraz opracowanego modelu wysokoczęstotliwościowego transformatora. Symulacje porównano z wynikami badań.
EN
Overvoltages transferred through power transformer windings affects on insulation of power transformers and equipment connected to its terminals. Overvoltages are transferred through transformers due to transient phenomena existing between windings, which are complex non-linear systems with electromagnetic couplings. Simulations of overvoltages transferred through windings are possible with usage of transformer models, which take into account phenomena occurring during propagation of overvoltages between windings. This paper presents simulations results of overvoltages transferred through transformer windings, performed with transformer models implemented in EMTP/ATPDraw software and designed high-frequency model. Simulation results were compared to measurements.
EN
This paper deals with frequency-dependent surge arresters models and transmission lines models utilized for insulation coordination studies. Simulations have performed by means of EMTP/ATP software. Various frequency-dependent surge arresters models and transmission lines models have been compared in this article. Simulations of lightning transient in analyzed power system have been performed and results presented in this paper for various surge arrester and overhead line models. Influence of models application during calculations on simulation results has also been analyzed.
PL
Artykuł dotyczy modelowania zmienno-częstotliwościowych modeli ograniczników przepięć oraz modeli linii przesyłowych, stosowanych do obliczeń koordynacji izolacji przy użyciu programu symulacyjnego EMTP/ATP. W niniejszym artykule przedstawiono wyniki symulacji przepięć podczas wyładowań piorunowych w rozpatrywanej sieci elektrycznej. Obliczenia przeprowadzono z wykorzystaniem różnych modeli ograniczników przepięć oraz linii przesyłowych, w celu porównania wpływu zastosowanego modelu ograniczników przepięć i linii przesyłowych, na wyniki symulacji.
15
PL
W sieciach elektroenergetycznych średnich napięć coraz szersze znaczenie znajdują wyłączniki próżniowe. Wyróżnia je duża trwałość i niezawodność działania. Wykazują one jednak specyficzne właściwości wpływające na przebiegi przepięć łączeniowych. W artykule przedstawiono analizę narażeń przepięciowych transformatorów rozdzielczych. Podstawą analizy były wyniki badań przepięć generowanych podczas wyłączania transformatorów wyłącznikami próżniowymi. Analizowano wpływ konfiguracji układów elektrycznych i ograniczników przepięć z tlenków metali na przepięcia łączeniowe.
EN
The importance of vacuum breakers used in medium voltage electrical networks has increased. They are extremaly durable and reliable and due to their special qualities. They can influence the switching surge waveforms. The following paper presents an analysis of overvoltages generated by vacuum breakers during the process of switching off the transformers. Additionally, the influence of configuration of electrical network and metal oxide surge arresters on switching overvoltages was also analysed.
EN
In-service stresses are the cause of progressive degradation of electrical insulation systems. The assessment of intensity and dynamics of these processes which are, among others, consequence of local working electric field strength is usually performed at sinusoidal voltage. However, in applications where power electronics converters are used the voltage stress has usually a form of fast switching pulses composing of repetitive sequences. Special problems for Pulse Width Modulation (PWM) driven induction motors arise from overvoltages and partial discharges (PD) in insulating systems of feeding cables and motors. The PWM waveforms produce complex overvoltages that stress the insulation more severely than sinusoidal voltage waveforms. The overvoltages form trials of pulses with very short rise times. Such conditions have essential influence on inception and activity of partial discharges in insulation systems. Selected aspects of these problems are presented in the paper: the numerical simulations of electric stress in coil-to-coil insulation of stator windings, the influence of the pulsed voltages modelling the PWM sequences, and the experimental results of PD in model twisted pair (TP) samples.
PL
Narażenia eksploatacyjne są powodem postępującej degradacji elektrycznych układów izolacyjnych. Ocena intensywności i dynamiki tych procesów, będących m.in. konsekwencją lokalnego, roboczego natężenia pola elektrycznego jest zwykle prowadzona dla napięcia sinusoidalnie zmiennego. W aplikacjach, w których stosowane są energoelektroniczne układy przekształtnikowe narażenia napięciowe mają formę impulsów szybkozmiennych, tworzących powtarzalne sekwencje. Szczególne problemy powstają w układach napędowych silników indukcyjnych z modulacją szerokości impulsów (PWM), a związane są one z przepięciami oraz wyładowaniami niezupełnymi (wnz) w izolacji kabli zasilających oraz silników. Przebiegi PWM wytwarzają złożone przepięcia, które narażają izolację w większym stopniu niż napięcia przemienne. Przepięcia tworzą ciągi impulsów o bardzo krótkich czasach narastania, co ma zasadniczy wpływ na powstawanie i aktywność wyładowań niezupełnych w układach izolacyjnych. Artykuł przedstawia wybrane aspekty tych problemów: symulacje numeryczne naprężeń elektrycznych izolacji międzyzwojowej, wpływ napięć impulsowych modelujących sekwencje PWM oraz wyniki badań eksperymentalnych wnz w próbkach modelowych typu para skręcona (TP).
EN
Nowadays photovoltaic power plants are becoming more and more popular in terms of power generation. Thus, it is necessary to provide safe and reliable working conditions in terms of power generation, conversion and transmission. DC power produced by PV panels is converted by inverter into AC and transformed into medium voltage level by a transformer, where entire power plant can be interconnected with distribution network. Most medium voltage switchgears are equipped with vacuum circuit breakers, which can cause excessive overvoltage escalation during switching off operations. In most severe cases it can lead to damage of working transformers or apparatus. This paper presents modeling techniques for described network in various topologies.
PL
Aktualne tendencje w rozwoju elektroenergetyki wskazują na budowę elektrowni fotowoltaicznych. Zapewnienie odpowiedniego poziomu bezpieczeństwa sieci dystrybucyjnej, poprzez którą będzie wyprowadzona generowana moc ma szczególne znaczenie z punktu widzenia pewności zasilania. Wyprowadzenie mocy z elektrowni fotowoltaicznej odbywa się zazwyczaj poprzez rozdzielnicę średniego napięcia wyposażoną w liczną aparaturę pomiarową, a także łączeniową w postaci wyłącznika próżniowego. Podczas otwierania lub zamykania wyłącznika może dojść do wielokrotnych zapłonów łuku elektrycznego pomiędzy jego zaciskami, co z kolei może prowadzić do uszkodzenia pracujących maszyn i urządzeń elektrycznych. W pracy zaprezentowano przykładowe symulacje przepięć z uwzlędnieniem przykładowych topologii sieci.
EN
Overvoltages occurring in electrical power networks are caused by changes of power network operation conditions (e.g. faults, lightning strikes or switching operations). In order to limitation of overvoltages, Metal Oxide Surge Arresters (MOSA) are installed in electrical networks. To analyze and determine overvoltages values in electrical power systems, dedicated simulations are necessary. This paper deals with frequencydependent surge arresters models utilized for overvoltages studies by means of EMTP/ATP simulation software. Various surge arresters models have been presented in this article. In order to compare simulation results, each surge arrester model has been used to perform lightning overvoltages simulations occurring in the analyzed electrical network. Simulation results show influence of surge arrester model type on obtained simulation results and estimated overvoltages observed in electrical network.
PL
Przepięcia występujące w sieciach elektroenergetycznych powodowane są przez zmianę warunków pracy obwodu – m. in. przez zwarcia, wyładowania atmosferyczne do linii przesyłowych, czy też operacje łączeniowe. W celu ograniczenia przepięć w sieciach elektroenergetycznych stosowane są ograniczniki przepięć z tlenków metali. Aby określić wartości przepięć podczas trwania stanów nieustalonych, konieczne jest przeprowadzanie symulacji komputerowych. Niniejszy artykuł zawiera opis zmienno-częstotliwościowych modeli ograniczników przepięć, wykorzystywanych do symulacji komputerowych. W celu porównania poszczególnych model, opracowano ich schematy zastępcze w programie EMTP/ATP, a także wykonano z ich użyciem analizę przepięć atmosferycznych w sieci elektroenergetycznej.
PL
W artykule przedstawiono wybrane aspekty analizy koordynacji izolacji wykorzystywane w praktyce projektowania stacji wysokich i najwyższych napięć. Omówiono główne założenia typowych analiz przepięciowych oraz przedstawiono metody obliczeniowe wspomagające proces poprawnego doboru środków ochrony odgromowej. Przedstawiono metody modelowania narażeń przepięciowych oraz modele poszczególnych elementów systemu, istotnych z puntu widzenia koordynacji izolacji. Szczególny nacisk położono na uwzględnienie zjawisk nieliniowych oraz charakterystyk częstotliwościowych, pozwalających na uzyskanie wymaganej dokładności obliczeń. Przedstawiono wyniki przykładowej analizy wpływu długości linii kablowej na wartości przepięć występujących w miejscu zainstalowania transformatora. Analizę przepięciową przeprowadzono dla schematu jednokreskowego typowej stacji rozdzielczej wysokich napięć w izolacji gazowej typu SF6, dla której przyjęto typowe parametry konstrukcyjne linii napowietrznych i kablowych, parametry konstrukcji wsporczych linii napowietrznych, oraz modele aparatów i urządzeń stacji wraz z doprowadzeniami, w szczególności modele transformatorów oraz ograniczników przepięć. Dla ograniczników przepięć dokonano oceny skuteczności i niezawodności ograniczników, związanej ze zdolnością ograniczników do pochłaniania i skutecznego odprowadzania energii wydzielanej podczas zadziałania, oraz pozwalającej na weryfikację poprawności doboru ograniczników dla pracy w danych warunkach przepięciowych. Przedstawiona w pracy analiza wskazuje, że połączenia kablowe mogą w znaczny sposób zmieniać narażenia powstałe w wyniku przepięć atmosferycznych w linie dochodzące do stacji, a tym samym wpływać na narażenia napięciowe, jakim w trakcie eksploatacji poddawane są układy izolacyjne aparatów i urządzeń.
EN
In the paper practical aspects of insulation co-ordination analyses are presented for high and ultra high voltage Gas Insulated Switchgear substations. Modeling methods are elaborated for proper selection of overvoltage protection measures, such as surge arresters, overhead lines towers grounding system, and line insulators chain lengths. The methods of lightning surges and substation equipment modeling were presented with special interest in modeling of nonlinear phenomena and high frequency characteristics, allowing for the required accuracy of the simulation results. The results for exemplary insulation co-ordination analysis are presented, showing the cable line impact on the substation overvoltages. The analysis was performed for a Single Line Diagram of an exemplary typical High Voltage GIS substation, for which a typical configuration and parameters of the elements have been assumed: overhead lines, substation apparatus, transformers and surge arresters. For the surge arresters, the analysis of the arresters reliable and efficient energy dissipation was analyzed, which allowed for evaluation and verification of proper selection and operation of the equipment in given voltage stress conditions and the assumed substation layout. The analyses presented in the paper shows that the cable line connections within or between substations have significant impact on overvoltages, which can threaten insulation system of transformers and can also influence selection of number and location placement of the surge arresters.
EN
Novel protection method of wind turbine transformers against high frequency transients occurring during switchgear operation is described in this paper. Presented results are continuation of research on Very Fast Transients mitigation methods previously published in literature [8]. Principles of novel suppressing device parameters optimization for windmill transformers are also included. ATP-EMTP simulations results for wind farm application were verified by full scale functional tests.
PL
W artykule przedstawiono nową metodę ochrony transformatorów turbin wiatrowych przed wysokoczęstotliwościowymi przepięciami mogącymi wystąpić w trakcie ich pracy. Przedstawione rezultaty są wynikiem kontynuacji wcześniejszych badań prowadzonych nad ochroną transformatorów dystrybucyjnych przed zakłóceniami o wysokokiej częstotliwości mogącymi wystąpić w sieci SN [8, 9]. Wyniki symulacji przepięć oraz doboru parametrów urządzeń ochronnych, zostały zweryfikowane w trakcie testów funkcjonalnych.