EN
Harmonic issue in the wind power plant is a concerning problem for both consumers and producers as that it affects the power quality of the distribution systems. This paper presents an improved control strategy for harmonic current compensation in wind turbine-based DFIG connected to the grid, using RIP-ADALINE for harmonic currents detection. A vector control-based fuzzy logic controller is applied to improve the active and reactive power flow. The active filtering is achieved using the grid side converter of the DFIG. The studied system has been simulated using MATLAB/SIMULINK platform. The results obtained show the effectiveness of the control strategies applied to the system Therefore the power quality in terms of grid current waveform, total harmonic distortion (THD) factor; frequency spectrum, and system power factor is improved within permissible standard values as defined by IEEE-519.
PL
Zagadnienia harmoniczne w elektrowni wiatrowej stanowią problem zarówno dla odbiorców, jak i producentów, ponieważ wpływają na jakość energii elektrycznej w systemach dystrybucyjnych. W artykule przedstawiono udoskonaloną strategię sterowania kompensacją harmonicznych prądu w elektrowni wiatrowej DFIG podłączonej do sieci, wykorzystującą RIIP-ADALINE do wykrywania harmonicznych prądu. Do poprawy przepływu mocy czynnej i biernej zastosowano sterownik wektorowy oparty na logice rozmytej. Filtracja czynna jest realizowana przy użyciu przekształtnika DFIG podłączonego do sieci. Badany system jest symulowany przy użyciu platformy MATLAB/SIMULINK. Uzyskane wyniki wskazują na skuteczność zastosowanych strategii sterowania, dlatego jakość energii elektrycznej w zakresie kształtu przebiegu prądu sieciowego, współczynnika całkowitych zniekształceń harmonicznych (THD), widma częstotliwości oraz współczynnika mocy systemu została poprawiona w zakresie dopuszczalnych wartości standardowych określonych przez IEEE-519.
EN
The purpose of this paper is to present and demonstrate the performance of a series active power filter (SAPF) with PI controller and Fuzzy controller associated by the pulse width modulation technique with simulation validations. This performance is manifested in the compensation of voltage sags and swells and distortions source voltage, the elimination of harmonic voltage and the regulation of the load terminal voltage by injecting a voltage component in series with the source voltage that is increased or decreased with respect to the source voltage, thus maintaining the load side waveforms as pure sinusoidal. The control method used in this work is not complex and is based on Synchronous Reference Frame (SRF) Theory, that is used to control the series active power filter. It is valid only in the phase system. The effectiveness of the suggested method is affirmed by the simulation results by MATLAB/Simulink®. These results show the capability of the proposed methods.
PL
Celem niniejszej pracy jest przedstawienie i zademonstrowanie działania szeregowego aktywnego filtra mocy z regulatorem PI i regulatorem rozmytym powiązanym z techniką modulacji szerokości impulsu wraz z walidacją symulacyjną. Działanie to przejawia się w kompensacji spadków i wzrostów napięcia oraz zniekształceń napięcia źródłowego, eliminacji harmonicznych napięcia oraz regulacji napięcia końcowego obciążenia poprzez wstrzykiwanie składowej napięcia szeregowo z napięciem źródłowym, które jest zwiększane lub zmniejszane w odniesieniu do napięcia źródłowego, utrzymując w ten sposób przebiegi po stronie obciążenia jako czyste sinusoidalne. Metoda sterowania zastosowana w niniejszej pracy nie jest skomplikowana i opiera się na teorii synchronicznej ramy odniesienia (SRF), która jest wykorzystywana do sterowania filtrem aktywnym. Obowiązuje ona tylko w układzie fazowym. Skuteczność proponowanej metody potwierdzają wyniki symulacji w programie MATLAB/Simulink®. Wyniki te pokazują możliwości proponowanych metod.
EN
This paper deals with the use of an adaptive linear (ADALINE) neural network in a harmonic extraction algorithm based on the calculation of instantaneous active and reactive powers. This technique, called "ANN-PQ", is developed in order to achieve an effective separation between the fundamental and harmonic components of the instantaneous powers, which used as reference variables in the control of the shunt active power filter (SAPF). In order to further increase the filtering performances of the SAPF, fuzzy logic theory is used in two parts of the SAPF control system. The first concerns the modulation technique where the hysteresis band of the current control strategy will be generated by a fuzzy inference system. In the second part, the fuzzy logic will be integrated into the external control loop of the SAPF to maintain the DC voltage at its reference value. The numerical simulation results, given at the end of this paper, clearly show the effectiveness of the proposed control techniques.
PL
W artykule omówiono zastosowanie adaptacyjnej liniowej sieci neuronowej (ADALINE) w algorytmie ekstrakcji harmonicznych opartym na obliczaniu chwilowych mocy czynnych i biernych. Technika ta, zwana „ANN-PQ”, została opracowana w celu uzyskania skutecznego oddzielenia składowych podstawowych i harmonicznych mocy chwilowych, które są wykorzystywane jako zmienne odniesienia w sterowaniu bocznikowym filtrem mocy czynnej (SAPF). W celu dalszego zwiększenia wydajności filtrowania SAPF, w dwóch częściach systemu sterowania SAPF zastosowano teorię logiki rozmytej. Pierwsza dotyczy techniki modulacji, w której pasmo histerezy jest generowane przez rozmyty system wnioskowania. W drugiej części logika rozmyta została zintegrowana z zewnętrzną pętlą sterowania SAPF, aby utrzymać napięcie stałe na jego wartości odniesienia.
4
Content available remote Genetic algorithm optimization of a SAPF based on the fuzzy- DPC concept
EN
This article presents a study on the use of the concept of direct power control (DPC) based on intelligent techniques in the control of a shunt active power filter (SAPF). In order to improve harmonic mitigation and reactive power compensation capabilities, the conventional switching table is replaced by a fuzzy inference system to generate the switching sequences of the shunt active power filter. To ensure an active power exchange stable and efficient, the DC voltage of the SAPF in controlled using an integrated proportional controller (PI) optimized by a heuristic optimization technique based on genetic algorithms (GA). The combination of two intelligent techniques in this proposed control strategy makes it possible to reduce ripples in different variables of the SAPF, to maintain the direct voltage at their reference value and to improve the THD of the grid current. The numerical simulation results obtained under Matlab / Simulink confirm the importance of the SAPF's proposed control technique
PL
W artykule opisano wykorzystanie metody DPC (direct power control) do poprawy parametrów bocznikowego filtru aktywnego SAPF. Konwencjonalna tabela przełączeń jest zastąpiona przez system logiki rozmytej. Do optymalizacji filtru wykorzystano też algorytm genetyczny.