Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 35

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The technological process of ready-mixed concrete production, which is designed to ensure the quality of concrete and the durability of the constructed buildings in accordance with the European Standard EN 206, consists of several stages. In this standard, to ensure the stability of both the concrete production process itself and its individual stages, appropriate requirements have been formulated. Some of these requirements pertain to the on-line stage of the production process, and some to the off-line stage. Some of these requirements, if not properly controlled, can disrupt the stability of the production process and also negatively impact the quality and durability of concrete structures. The article analyzes the significance of these standard requirements. For this purpose, the AHP method was used, and the Pareto principle was applied to interpret the results. The AHP analysis showed that three out of seven requirements have the most significant impact on the quality of concrete and concrete structures. These are: the constituents of concrete, the limitations for concrete composition, and the delivery of fresh concrete. The applied Pareto principle confirmed their dominant role. These three criteria account for almost 80% of the importance in ensuring the quality of concrete.
EN
The knowledge of the impact and the load-bearing capacity of unstrengthened/strengthened structures is a crucial source of information about the safety of masonry buildings near deep excavations, especially in dense urban areas. Incorrect calculations made for such designs can seriously affect not only an analyzed object but also the adjacent buildings. The safety of masonry buildings can be determined by many factors that are closely related to the hazards presented during the performance of deep excavations. These factors are at first identified and then prioritized. The AHP process in the multi-criteria analysis was used to support the decision-making process related to the verification of factors affecting the safety assessment of masonry buildings in the area of deep excavations. The proper design of building structures, including the verification of the structure strengthening near deep excavations, was found to be the most significant factor determining the safety of such buildings. The methodology for proceeding with the verification of ultimate (ULS) and serviceability (SLS) limit states in accordance with the literature data, current regulations, such as Eurocode 6 and other design standards, and the know-how of the authors, described in this paper was the next stage of the discussed analysis.
PL
Stropy z płyt kanałowych pomimo ponad stu lat historii i miliarda metrów kwadratowych wykonanych tego typu konstrukcji w samej Europie nadal w pewnych aspektach projektowych budzą wątpliwości. W artykule przedstawiono wyniki wpływu krótkotrwałych i długotrwałych obciążeń na pełnoskalowy strop z płyt kanałowych o wymiarach 6,31 x 6,31 m. Badanie przeprowadzono pod niesymetrycznym obciążeniem grawitacyjnym, a ostatni pomiar wykonano po 665 dniach. Wykonana analiza obliczeniowa wykazała ponad trzykrotne przeszacowanie ugięć modelu płyty jednokierunkowej w odniesieniu do badań doświadczalnych. Przedstawiono uproszczone przestrzenne modele obliczeniowe, wraz z podaniem kryteriów stosowania. Badania i analizy wykazały, że powszechnie stosowana metoda obliczeniowa prowadzi do bardzo konserwatywnych wyników - nie oddając rzeczywistej charakterystyki pracy stropów z płyt kanałowych.
EN
Despite over a hundred years of history and a billion square meters made in Europe alone, hollow-core slabs still raise doubts in some design aspects. The article presents the results of the short-term and long-term loads on a full-scale hollow-core slab with dimensions of 6.31 x 6.31 m. The test was carried out under an unsymmetrical gravity load, and the last measurement was carried out after 665 days. The computational analysis indicates over three times overestimated deflections of the one-way slab model compared to the experimental tests. Simplified spatial computational models are presented, along with application criteria. The research and the presented analyses have shown that the commonly used calculation method leads to very conservative results, without reflecting the actual performance characteristics of hollow-core slabs.
5
Content available remote Rozwój konstrukcji murowych w Polsce
PL
Konstrukcje murowe w Polsce przez ostatnie dwadzieścia pięć lat mocno się rozwinęły. Wprowadzono nowe elementy murowe i zaprawy, dzięki czemu mury wznosi się obecnie szybciej i dokładniej. Zwiększono wymagania dotyczące parametrów mechanicznych, cieplnych i akustycznych ścian murowanych. Opracowano zaprawy do cienkich spoin oraz kleje do łączenia elementów murowych. W artykule przedstawiono stan obecny i perspektywy rozwoju konstrukcji murowych.
EN
Masonry structures in Poland have developed significantly over the last twenty-five years. New masonry elements and mortars were introduced, thanks to which the walls are now erected faster and more accurately. The mechanical, thermal, and acoustic parameters of masonry walls were increased. Mortars for thin joints and adhesives for joining masonry elements have been developed. The article presents state and development prospects of masonry structures.
PL
W artykule opisano możliwości nieniszczących badań istniejących konstrukcji z elementów murowych, z autoklawizowanego betonu komórkowego. Opracowano zależności umożliwiające wyznaczenie znormalizowanej wytrzymałości na ściskanie autoklawizowanego betonu komórkowego, metodą semi-nieniszczącą MDT. Wykorzystano ogólną postać znanej z diagnostyki betonu zwykłego krzywej Neville’a, którą skalibrowano do ABK nominalnych klas gęstości 400, 500, 600 i 700. Wykonano badania i opracowano dodatkowe zależności empiryczne, pozwalające uwzględnić wpływ gęstości i wilgotności. Przedstawiono ponadto ultradźwiękową metodę nieniszczącą NDT wykalibrowaną na standardowych próbkach sześciennych 100×100×100 mm, o różnej gęstości i wilgotności. Oprócz nieniszczącej metody ultradźwiękowej zastosowano także metodę sklerometryczną skalibrowaną na całych elementach murowych, ograniczoną do jednej nominalnej gęstości, o zróżnicowanej wilgotności. Przedstawiono praktyczną ocenę wytrzymałości ABK, w istniejącej konstrukcji murowej.
EN
The article describes the possibilities of non-destructive testing of existing structures, made of autoclaved aerated concrete [AAC] masonry units. Relationships that allow the determination of the normalized compressive strength of autoclaved aerated concrete, were developed with the MDT semi-non-destructive method. The general form of the Neville curve, known from the diagnosis of plain concrete was used, which was calibrated to AAC of nominal density classes 400, 500, 600 and 700. The tests were performed and additional empirical relationships were built, to allow for the influence of density and moisture. Moreover, an ultrasonic non-destructive NDT method calibrated on standard cubic 100 × 100 × 100 mm samples of various densities and moisture, is presented. In addition to the non-destructive ultrasound method, the sclerometric method, calibrated on the entire masonry elements, limited to one nominal density of 600 kg/m3 with varying moisture, was also used. A practical application of AAC strength assessment in the existing masonry structure, has been presented.
EN
The internal forces in stiffening walls are usually determining by numerical methods. Extreme values of forces and displacements can be achieved without significant problems. The numerical model is always labour-intensive; therefore, it is not used for single-family or multi-family buildings with a simple wall layout. To calculate efficiently internal forces in such walls uses an analytical model. Eurocode 6 (prEN 1996-1-1:2019) does not provide specific guidelines for determining geometrical characteristics and procedures for calculating the values of internal forces in the stiffening walls. The use of numerical methods and other reliable methods was allowed. The paper presents the adaptation of the total stiffness method to determine internal forces in a building with a simple wall system. The method was based on dividing the masonry wall with openings into pillars, lintels, bottom sprandels and flanged walls. The analytical results were compared with linear-elastic FEM calculations. It has been demonstrated that flexural stiffness, shear stiffness and localization of rotation centre (RC) had a crucial impact on masonry structure.
PL
Zasadniczym celem pracy była adaptacja metody całkowitej sztywności ścian do rozdziału obciążeń na ściany usztywniające w budynku o prostym układzie ścianowym według ogólnych zaleceń Eurokodu 6. Na wstępie przedstawiono normowe zalecenia dotyczące ścian usztywniających podane w Eurokodzie 6. Następnie zaproponowano uszczegółowienie procedury obliczeniowej. Przyjętą procedurę porównano z wynikami obliczen MES modelu budynku o prostym układzie ścianowym. Wiekszość zaleceń normowych nie podaje szczegółowych wytycznych i procedur rozdziału sił oraz wyznaczania sił wewnętrznych w murowanych ścianach usztywniających. Przepisy ograniczają się do ogólnych zaleceń dotyczących identyfikacji ścian usztywniających, ewentualnej współpracy z innymi elementami budynku oraz do opisu warunków konstrukcyjnych. Dotyczy to również projektu Eurokodu, 6 w którym jednak do stosowania dopuszczono wiarygodne metody analityczne lub metody numeryczne bazujące na MES. W pracy dokonano adaptacji przepisów kanadyjskich (National Building Code of Canada (NBCC) 2005) do opracowania metody obliczania całkowitej sztywności ściany. Uwzględniając zapisy Eurokodu 6 (w aspekcie współpracy z innymi ścianami) wyznaczono zależności pozwalające na wyznaczenie przemieszczeń ściany z otworami, dzięki podziałowi na elementy składowe. Przemieszczenia składowych elementów ściany wyznaczono w zależności od geometrii i warunków brzegowych ściany. Przy obliczeniach całkowitej sztywności ściany uwzględniono odkształcenia giętne oraz postaciowe.
PL
Technika ultardźwiękowa wykorzystywana jest do określania wytrzymałości na ściskanie lub wykrywania wewnętrznych nieciągłości struktury. Używana jest także do określania stanu odkształceń oraz naprężeń w konstrukcjach i bazuje na efekcie elastoakustycznym (AE). Dotychczas efekt AE dość dobrze rozpoznano w materiałach jednorodnych, natomiast w przypadku materiałów porowatych czy niejednorodnych, takich jak beton czy skała, badania nie były prowadzone. Przedmiotem badań prezentowanych w artykule było wykorzystanie zjawiska AE do wyznaczania naprężeń w niewielkich modelach muru wykonanego z elementów z autoklawizowanego betonu komórkowego. Przedstawiono zależności wiążące wartość naprężeń ściskających z prędkością podłużnej fali ultradźwiękowej z uwzględnieniem wilgotności.
EN
The ultrasonic technique is used not only to determine the compressive strength or to detect internal structure discontinuities. It is also used to determine the state of deformation and stress in structures and based on the elastoacoustic effect (AE). So far, the AE effect has been recognized quite well in homogeneous materials in the case of porous or heterogeneous materials such as concrete or rock, due to the large dispersion of the results, the study has not been conducted. The subject of the presented research was the use of the AE efect to determine the stresses in small models of masonry made of autoclaved aerated concrete masonry units. The relationship between the value of compressive stresses and the velocity of the longitudinal ultrasonic wave with regard to humidity was presented.
PL
Przedmiotem prezentowanych badań jest wykorzystanie efektu elastoakustycznego AE do wyznaczania naprężeń w murze wykonanym z autoklawizowanego betonu komórkowego poddanego osiowemu ściskaniu. Wykorzystano zależności wiążące wartość naprężeń ściskających z prędkością podłużnej fali ultradźwiękowej z uwzględnieniem wilgotności ABK. Identyfikację stanu naprężeń przeprowadzono w dziewięciu niewielkich modelach muru poddanego osiowemu ściskaniu. Wykazano, że średnie naprężenia ściskające w murze, wyznaczone proponowaną metodą, można z zadowalającym poziomem ufności rozpoznać do poziomu ok. 50% naprężeń niszczących. Przy naprężeniach rzędu 75% naprężeń niszczących wyniki okazały się istotnie zaniżone.
EN
The subject of the presented research was the use of the AE electroacoustic effect to determine the stresses in a wall made of AAC subjected to axial compression. The relationships linking the value of the compressive stresses with the velocity of the longitudinal ultrasonic wave, taking into account the AAC humidity, were used. The stress state was identified in 9 small models of masonry subjected to axial compression. It was shown that the average compressive stresses in the wall determined by the proposed method can be recognized with a satisfactory level of confidence up to the level of about 50% of the failure stresses. At higher stresses of 75% of the breaking stress, the results turned out to be significantly underestimated.
PL
W artykule przedstawiono wyniki badania ścian niezbrojonych i zbrojonych, z otworami różnych kształtów, wykonanych z silikatowych elementów murowych. Podstawowym celem przeprowadzonych eksperymentów było określenie wpływu zastosowanego zbrojenia na morfologię zarysowań oraz mechanizm zniszczenia. Wszystkie ściany wykonano z silikatowych elementów murowych z pionowymi drążeniami (grupa I wg PN-EN 1996-1-1:2013). Zbadano 12 ścian o zewnętrznych wymiarach l = 4,45 m, h = 2,45 m, t = 180 mm z otworami zróżnicowanymi pod względem kształtu i wymiarów. Do zbrojenia zastosowano stalowe kratowniczki typu EFZ 140/Z 140 type (typ Z1) oraz siatki z tworzywa sztucznego (typ Z2). Wykazano, że rozwój zarysowań zależał od wielkości otworu. W ścianach zbrojonych propagacja zarysowań była istotnie ograniczana.
EN
The article presents the results of tests of unreinforced and reinforced walls with openings of various shapes made of calcium silicate masonry units. The main aim of the conducted experiments was to determine the influence of the applied reinforcement on the cracking morphology and the failure mechanism. All walls are made of calcium silicate masonry elements with vertical traverses (group I according to PN-EN 1996-1-1:2013). 12 walls with external dimensions of l = 4,45 m, h = 2,45 m, t = 180 mm with openings of different shape and dimensions were constructed and tested. Steel trusses of the EFZ 140/Z 140 type (type Z1) and plastic meshes (type Z2) were used for reinforcement. It was shown that the development of cracking depended on the size of the opening. In reinforced walls, the propagation of scratches was significantly limited.
PL
W artykule przedstawiono wyniki badań ścian zbrojonych z otworami o rożnym kształcie wykonanych z silikatowych elementów murowych. Określono wpływ zbrojenia na zależność naprężenie ścinające – kąt odkształcenia postaciowego oraz wartość naprężeń rysujących i niszczących. Wykonano i zbadano 12 ścian o zewnętrznych wymiarach l = 4,45 m, h = 2,45 m, t = 180 mm z otworami zróżnicowanymi pod względem kształtu i wymiarów. W przypadku wszystkich zbrojonych modeli stopień zbrojenia elementów wynosił ρ = 0,07 (> ρmin = 0,05). Ściany badano przy wstępnych naprężeniach ściskających σc = 0,1; 1,5 lub 0,75 N/mm2. Wykazano istotny wpływ zbrojenia na sztywność ścian oraz wartość analizowanych naprężeń w chwili zarysowania i zniszczenia.
EN
The article presents the results of research on reinforced walls with openings of various shapes made of calcium-silicate masonry units. The main aim of the conducted experiments was to determine the influence of the applied reinforcement, on the relationship shear stress – shear strain angle and the value of cracking and ultimate stresses. 12 walls with external dimensions of l = 4,45 m, h = 2,45 m, t = 180 mm with openings of different shape and dimensions were constructed and tested. In all reinforced models, the element reinforcement ratio was ρ = 0,07 (> ρmin = 0,05). The walls were tested at the initial compressive stress of σc = 0,1; 1,5 or 0,75 N/mm2. The significant influence of the reinforcement on the wall stiffness and the values of the analyzed stresses at cracking and ultimate was demonstrated.
PL
W artykule opisano badanie wpływu zbrojenia spoin wspornych na wytrzymałość na ściskanie i ścinanie murów z autoklawizowanego betonu komórkowego (ABK) zgodnie z wytycznymi odpowiednio normy europejskiej EN 1052-1:2000 i amerykańskiej ASTM ES519-81. Zastosowano zbrojenie w postaci pasów siatki rozwijanej z rolki, składającej się z linek stalowych z osnową z włókna szklanego. Wpływ tego typu zbrojenia porównano również z wynikami badań ścian murowanych z ABK bez zbrojenia oraz wzmocnionych odpowiednio zbrojeniem kratownicowym i siatką syntetyczną.
EN
This paper presents a research of influence of horizontal reinforcement on compressive and shear strength of Autoclaved Aerated Concrete (AAC) masonry. Specimens were tested according to guidelines of EN 1052-1:2000 and ASTM ES519-81 code in case of compression and shear test respectively. Reinforcement in the form of strips of mesh rolled out from a roll, consists of steel cords with an interwoven fiberglass roving was used. The influence of this type of reinforcement was also compared with the results of tests of AAC masonry walls without reinforcement, reinforced with truss type reinforcement and reinforced with synthetic mesh respectively.
PL
W artykule przedstawiono wyniki badań wytrzymałości na ścinanie wzmocnionych powierzchniowo murów z elementów z autoklawizowanego betonu komórkowego (ABK). Stanowią one kolejny etap badań doświadczalnych mających na celu określenie wpływu wzmocnienia powierzchniowego systemem FRCM na wytrzymałość murów z ABK. Badania przeprowadzono wg procedury A zgodnie z wymaganiami normy PN-EN 1052-3 [6]. Program badań obejmował modele wzmocnione z jednej oraz dwóch stron. Uzyskane wyniki porównano z wynikami badań modeli bez wzmocnienia [4].
EN
This paper describes the results from the test of the shear strength of superficial strengthened of walls made of autoclaved aerated concrete (AAC) masonry units. These tests constitute the next stage of experimental research aimed at determining the influence of surface reinforcement with the FRCM system on the strength parameters of AAC walls. The tests were carried out in accordance with the procedure A of PN-EN 1052-3 [6]. The research program included models reinforced on one and two sides. The results were compared with the test results of models without reinforcement [4].
15
PL
Przeprowadzono badania wpływu krótko trwałych oraz długotrwałych obciążeń pełnoskalowego modelu stropu panelowego TERIVA PANEL o wymiarze 6,30 x 6,30 m. Panele TERIVA PANEL wykonano jako prefabrykowane płyty sprężane w układzie dwóch odwróconych żeber połączonych wspólną półką dolną. W płytach specjalnie ukształtowano złącza boczne (zamek), umożliwiające przenoszenie obciążeń pomiędzy panelami. Badanie prowadzono pod obciążeniem grawitacyjnym umieszczonym na stropie przykładanym sekwencyjnie zgodnie z ustalonymi schematami, a pomiary realizowano za pomocą czujników indukcyjnych. W celu weryfikacji wpływów długotrwałych, w tym możliwości wystąpienia klawiszowania, obciążenie przyłożono niesymetrycznie. Porównanie uzyskanych przemieszczeń z modelu doświadczalnego z obliczeniami modelu płyty jednokierunkowej wykazały ponad trzykrotną różnicę uzyskanych wyników ugięć. Obecnie stosowane metody obliczeniowe prowadzą do bardzo konserwatywnych wartości ugięć, nie oddając rzeczywistego modelu pracy stropów o złączach zapewniających współpracę prefabrykatów.
EN
Tests of a full-scale slab model with dimensions of 6,30 x 6,30 m, built of TERIVAPANEL panels, were carried out under short-term and long-term load. TERIVA PANEL panels are half precast, prestressed concrete slabs with ribs connected at the bottom with specially shaped cross-connection (shear key), enabling transfer loads between the panels. The tests were carried out under load placed on the top of the slab. Additionally, the load was applied sequentially, and measurements were made by the electronic method. In one of the stages of long-term testing, the load was applied to one half of the slab to examine the possibility of faulting. Comparing the displacements obtained from the experimental model with the calculations of the one-way slab model showed more than threefold differences in the obtained results. The currently used calculation methods lead to very conservative displacement values, not reflecting the actual work model of slabs with joints transferring loads between the panels.
PL
Przedstawiono postępowanie przy sprawdzaniu nośności przekroju ściany ścinanej przy wykorzystaniu wykresu interakcji, zbudowanego według zaleceń Eurokodu 6 (prEN 1996-1-1:2019). Sformułowano niezbędne równania określające nośność przekroju w funkcji pionowego obciążenia NEd. Przeanalizowano wpływ kształtu ściany oraz mimośrodu obciążenia pionowego na kształt wykresu interakcji.
EN
This paper describes the procedure for verifying shear load capacity by means of the interaction diagram drawn as specified in Eurocode 6 (prEN 1996-1-1:2019). Necessary equations for determining load-carrying capacity of cross-section against vertical load NEd were worked out. The effect of wall shape and eccentricity of vertical load on the shape of the interaction diagram was analysed.
PL
Jedną z metod określania stanu odkształcenia i naprężenia istniejących konstrukcji jest tensometria ultradźwiękowa wykorzystująca efekt akustoelastyczny (AE). Metoda jest stosowana głównie w przypadku materiałów jednorodnych, takich jak stal lub tworzywa sztuczne. Przedmiotem prezentowanych badań było wykorzystanie zjawiska AE do wyznaczania naprężeń w próbkach z autoklawizowanego betonu komórkowego. Wyznaczono zależności wiążące naprężenia ściskające z prędkościami podłużnej fali ultradźwiękowej, z uwzględnieniem wilgotności.
EN
One of the methods of determining the state of deformation and stresses of existing structures is ultrasonic strain gauges using the acoustoelastic effect (AE). The method is mainly used for homogeneous materials such as steel or plastics. The subject of the presented research was the use of the AE efekt to determine the stresses in samples made of autoclaved aerated concrete. The relationships linking the value of compressive stresses with the velocity of the longitudinal ultrasonic wave with regard to humidity were determined.
EN
Vector II slab was tested on a natural scale (a slab with a dimension of 6.30 × 6.30 m) and a strip 6.30 m long and 1.20 m wide. The Vector II slab is built by precast panel 60 cm wide, 4 cm thick and 14-20 cm thick concrete overtopping on the construction site. The main purpose of the slab tests on a natural scale was to observe the "faulting" effect and temporary deflections. During the tests, the displacements in the area of the panel joints in the middle of the slab span were recorded. The maximum difference in displacement between adjacent panels of the slab model was 0.16 mm, and the vertical displacement was 1.9 mm. The strip model had no cracks that could indicate a interface cracks between the precast element and the concrete overlay. After completion of the field tests, the load was left on the slab model to verify long-term effects.
PL
Artykuł przedstawia zachowanie się niezbrojonych połączeń ścian wykonanych z elementów murowych z autoklawizowanego betonu komórkowego (ABK). Na podstawie badań własnych zdefiniowano i opisano poszczególne fazy pracy połączenia. Zaproponowano empiryczne podejście umożliwiające określenie sił i przemieszczeń połączenia ścian z wykorzystaniem parametrów uzyskiwanych ze standardowych testów zawartych w przepisach normowych.
EN
The article presents the description of the behavior of unreinforced joints of walls made of masonry elements of autoclaved aerated concrete (AAC). Based on our own research, the individual phases of the connection were defined and described. An empirical approach was proposed to determine the forces and displacements of the wall connection using parameters obtained from standard tests included in the standard provisions.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.