Power System Stabilizer (PSS) is a supplementary control that provides additional control actions on the excitation side of the generator. In this study a Craziness Particle Swarm Optimization (CRPSO) based tuning method is proposed to optimize the PSS parameters. CRPSO is a development of the conventional PSO method, where in conventional PSO there is a tendency to achieve premature convergence. This condition causes the solution obtained to be the optimum local. With optimal PSS parameters, the optimal PSS performance is obtained. The combination of PSS and excitation is used to reduce the oscillation that occurs in the system. In this research a case study of load addition and load shedding is used. From the simulation results, it is found that system performance is more optimal using CRPSO than using conventional PSO. System performance is shown by the response of the generator speed and rotor angle which results in a small overshoot and a faster settling time when there is an increase in load and also load shedding. Increased system performance is also viewed from the negative system eigenvalue, negative eigenvalue indicates the system is stable.
PL
Stabilizator systemu zasilania (PSS) jest dodatkowym sterowaniem, które zapewnia dodatkowe działania sterujące po stronie wzbudzenia generatora. W tym badaniu zaproponowano metodę strojenia opartą na Craziness Particle Swarm Optimization (CRPSO) w celu optymalizacji parametrów PSS. CRPSO jest rozwinięciem tradycyjnej metody PSO, gdzie w konwencjonalnym PSO istnieje tendencja do osiągnięcia przedwczesnej konwergencji. Stan ten powoduje, że otrzymane rozwiązanie jest optymalne miejscowo. Przy optymalnych parametrach PSS uzyskuje się optymalną wydajność PSS. Połączenie PSS i wzbudzenia służy do zmniejszenia oscylacji występujących w systemie. W tym badaniu wykorzystano studium przypadku dodawania i odciążania. Z symulacji wynika, że wydajność systemu jest bardziej optymalna przy użyciu CRPSO niż przy użyciu konwencjonalnego PSO. Wydajność systemu jest pokazana przez reakcję prędkości generatora i kąta wirnika, co skutkuje niewielkim przeregulowaniem i szybszym czasem ustalania, gdy występuje wzrost obciążenia, a także zmniejszenie obciążenia. Zwiększona wydajność systemu jest również postrzegana z ujemnej wartości własnej systemu, ujemna wartość własna wskazuje, że system jest stabilny.
EN
Wind turbine generator (WTG) installation has been rapidly growing globally in the last few years. In the year of 2017, the WTG installation has reached a global cumulative installation of about 539 GW. Among several types of WTG, the doubly fed induction generator (DFIG) has been taking a large portion of the overall WTG installation since 2004. This popularity is due to the DFIG several advantages that include more extracted energy when compared with the fixed speed type and low cost due to the one-third size of the used converters when compared to the full converter type. However, the DFIG is vulnerable to grid faults. In this paper, a new application of Vector Based Hysteresis Current Regulator (VBHCR) of STATCOM is introduced to enhance the dynamic performance of DFIG-based wind turbine farm. The system under study is investigated using Matlab. Robustness of the proposed VBHCR is investigated through exploring the system performance under various levels of voltage sags. Simulation results show that for certain level of voltage sags at the point of common coupling (PCC), VBHCR-STATCOM can effectively improve the performance of the DFIG. As a result, voltage profile at the PCC can comply with the fault ride through codes of Spain to avoid the disconnection of the DFIGs from the grid.
PL
Zaprezentowano nowy sterownik do turbiny wiatrowej DFIG – Vector Based Hysteresis Current Regulator VBHCR systemu STATCOM umożliwiający poprawę dynamiki. Zbadano pracę układu przy różnych poziomach zapadu napięcia. Stwierdzono poprawę dynamiki i zabezpieczenie przed odłączeniem generatora od sieci.
EN
Wind energy becomes a popular source for renewable energy based power plants since a recent decade ago. Within many types of wind turbine generator (WTG), Doubly Fed Induction Generator currently dominating the market niche by about 64% on all installed capacity all around the world in 2015. A DFIG consists of two converters that linked by a capacitor or so-called as DC link that works to allow the transfer energy from WTG to the grid and vice versa. These converters are very sensitive to any faults particularly when the DC link voltage reach beyond the safety margin, it may be ended with the disconnection of DFIG to avoid any damage on the DFIG's converters. This paper aims to investigate the impact of SMES Unit on DC link voltage of DFIG during various types and levels of faults. The study was conducted through a simulation program and shows that SMES Unit is very effective in reducing the voltage at DC link during grid swell events and slightly affecting the voltage overshoot during grid sag and short circuit events. For the last two cases, the SMES Unit control system is designed to work properly and optimally, therefore, impact of SMES rather insignificant due to the DC link voltages are within the safety margin, however, when DC particularly for the case where the DC link voltage tends to increase and potential to damage the switching parts of DFIG, the SMES Unit could significantly compensate the faults and maintain the voltage within the safety margin.
PL
W artykule analizowany jest wpływ układu SMES (superconducting magnetic energy storage) na pracę układu generatora DFIG typu. DC-link przy różnych typach zakłóceń na przykład zapadów napięcia lub zwarć w sieci. Układy konwerterów w systemie DFIG są bowiem bardzo czułen na przekroczenie przez napięcie marginesu bezpieczeństw co skutkować może odłączeniem generatora.