Comparison of dichromate and ethanol-chlorobenzene dosimeters in high dose radiation processing

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Dichromate and ethanol-chlorobenzene dosimeters were studied in conditions of annual temperature changes during process control at the Radiation Unit of the Vinča Institute. Measurements were performed in February (10-14°C) and August (22-35°C) for the dose range 10-50 kGy. The difference between measurements using these dosimeters is in agreement with the previous laboratory studies of temperature effect on the dose response of a dichromate dosimeter. The absorbed doses measured by these two dosimeters are in good agreement and the difference is within a limit of 3% for the studied dose range. The uncertainties of dose measurements using dichromate dosimeter arising from irradiation during annual temperature changes appear to be well within acceptable limits indicating that this dosimeter can be used as a routine dosimeter.
Słowa kluczowe
Czasopismo
Rocznik
Strony
85--87
Opis fizyczny
Bibliogr. 8 poz., rys.
Twórcy
autor
autor
  • Institute of Nuclear Sciences "Vinča", P. O. Box 522, 11001 Belgrade, Serbia,Tel./Fax: +381 113 441 953,, bojana@vin.bg.ac.yu
Bibliografia
  • 1. IOS (1993) Guide to expression of uncertainty in measurement.International Organization for Standardization,Geneva, Switzerland
  • 2. ISO/ASTM 51538-2002 (2002) Standard practice for use of the ethanol-chlorobenzene dosimetry system
  • 3. ISO/ASTM 51707-2002 (E) (2002) Standard guide for estimating uncertainties in dosimetry for radiation processing
  • 4. ISO/ASTM 51401-2003 (E) (2003) Standard practice for use of a dichromate dosimetry system
  • 5. Mai HH, Ražem D (1991) Temperature effects on the ethanol-chlorobenzene dosimeter (Dvornik dosimeter).Int J Appl Radiat Isot 42;7:637–641
  • 6. Mai HH, Tachibana H, Kojima T (1998) Effects of temperature during irradiation and spectrophotometry analysis on the dose response of aqueous dichromate dosimeters. Radiat Phys Chem 53:85–91
  • 7. Marković VM, Eymery R, Yuan HC (1977) A new approach to 60Co plant design for introduction of radiation sterilization in developing countries. Radiat Phys Chem 9:625–631
  • 8.Sharpe P, Miller A (1999) Guidelines for calibration of dosimeters for use in radiation processing. NPL Report,CIRM 29
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUJ6-0023-0026
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.