The influence of mechanical factors in the biological adaptation process of implants

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents the analysis of mechanical properties of implants basing on the finite elements methods (FEM) and experimental techniques of the mechanics of materials. Models of normal femoral bone and hip joint after the endoprosthesis implantation have been worked out. Stress patterns in these biomechanical systems have been determined. Mechanical material properties of polyethylene endoprosthesis cup have been determined as well. The results indicate that exposure to X-rays and ageing leads to hardening of the cups. The influence of geometrical and material feactures of stems and cups of endoprosthesis of hip joint on its adaptation process in the human organism has been discussed. Important mechanical properties of implants, which influence their behaviour in the human organism, have been determined. It has been stated that prediction of biological properties and behaviour of new implants in human body could be based on methods applied in mechanics of materials.
Twórcy
autor
  • Silesian University of Technology, Gliwice
autor
  • Public Hospital in Siemianowice Śląskie
autor
  • Silesian University, Katowice
Bibliografia
  • [1] KUSZ D., Application of densitometric examination in the evaluation of hip joint endoprothetis results with the aid of computer simulation of stress patterns in acetabular bone tissue. Annales Academiae Medicae Silesiensis, Katowice 1998 (in Polish)
  • [2] KUSZ D., OKRAJNI J., Evaluation of the influence of effort state in femoral joint after implantaion Weller's endoprothesis upon changes occurring in cone tissue in correlation with densitometric examination. Polish Orthopaedics Surgery, 1997; 62(3), pp. 225-232 (in Polish).
  • [3] KUSZ D., TOKAROWSKI A., BOŻEK M., JURKIEWICZ A., KALETA M., SKABA T.: examination in cement alloplastics of hip joint Polish Orthopaedics Surgery, 1996; 61(supl. 3A), pp. 83-87 (in Polish).
  • [4] KUSZ D., OKRAJNI J., DOMAGAŁA-PASEK A., Modem evaluation possibilities of mineral changes in femoral joint after total alloplastics of a hip joint. Annales Academiae Medicae Silesiensis (supl.29), Katowice 1999, pp.81 - 90 (in Polish).
  • [5] Gruen T.A, McMEICE G.M., AMSTUTZ H.C., "Modes of failure" of cemented stem-type femoral components. Clin. Orthop., 1979, pp.17-27.
  • [6] OKRAJNI J., KUSZ D., ŻMUDZKI J., Biological and mechanical conditioning of adaptation processes in acetabular bone tissue. Annales Academiae Medicae Silesiensis (supl.29), Katowice 1999, pp.1 19-127 (in Polish).
  • [7] HUISKES R., Van RIETBERGEN B., Preclinical testing of total hip stem. Clin. Orthop., 1995; 319, pp. 64-76.
  • [8] BĘDZIŃSKI R., Engineering Biomechanics. Chosen issues. Print of Wroclaw University of Technology, Wrocław 1997 (in Polish)
  • [9] OKRAJNI J., MYALSKI J., TOBOREK J., KUSZ D., CYBO J., DUDA P., Forecasting changes in polyethylene properties of polyethylene cup component of a hip joint endoprothesis. Annales Academiae Medicae Silesiensis (supl.29), Katowice 1999, pp.128-133 (in Polish).