PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The influence of saliva and its substitutes on corrosion of some implant alloys

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The purpose of this paper is evaluation of the influence of human saliva and its substitutes on the corrosion re sistance of some implant alloys used in stomatology, which included: austenitic steel (316L), titanium alloy (Ti6Al4V), and cobalt alloy (CoCrMo). Corrosion studies were conducted by means of the potentiodynamic method with the application of the VoltaLab 21 kit with VoltaMaster 4 software. The reference electrode was a saturated calomel electrode (SCE), whereas the counter electrode was a platinum electrode. The results of conducted studies indicate an increased current density in the passive range on potentiodynamic curves of studied alloys in the envi- ronment of human saliva, and also in a commercial saliva solution – Mucinox. On the basis of conducted corrosion studies, it can be stated that in terms of corrosion resistance the developed saliva substitutes may constitute competitive solutions to commercial saliva substitutes. The prepared substitutes should be studied further from the perspective of practical application for patients. The original value of the paper is a proposition of new saliva substitutes.
Rocznik
Strony
69--74
Opis fizyczny
Bibliogr. 42 poz., il. tab., wykr.
Twórcy
  • Faculty of Mechanical Engineering, Department of Materials and Biomedical Engineering, Bialystok University of Technology, ul. Wiejska 45 C, 15-351 Bialystok, Poland
Bibliografia
  • 1. Adya N., Alam M., Ravindranath T., Mubeen A., Saluja B. (2005), Corrosion In titanium dental implants: literature review, The Journal of Indian Prosthodontic Society, Vol 5, 3, 126-13.
  • 2. Amerongen A. V. N., Veerman E. C. I. (2002), Saliva - the defender of the oral cavity, Oral Diseases, 8, 1, 12-22.
  • 3. Andrysewicz E., Dąbrowski J. R., Leonow G. (2008), Methodologi-cal aspects of rheological testing saliva, Twoj Prz. Stomatol., 10-15.
  • 4. Barao V. A. R., Mathew M. T., Assuncao W. G., Chia-Chun Yuan J., Wimmer M. A., Sukotjo C. (2011), Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH – an electro-chemical study, Clin Oral Impl, 1–8.
  • 5. Bedi R. S., Beving D. E., Zanello L. P., Yan Y. (2009), Biocompati-bility of corrosion-resistant zeolite coatings for titanium alloy biomedi-cal implants, Acta Biomaterialia, 5, 8, 3265-3271.
  • 6. Bellefontaine G. (2010), The Corrosion Of CoCrMo. Alloys For Biomedical. Applications, University of Birmingham.
  • 7. Blackwood D. J. (2010), Corrosion In body fluid, Singapore, 1208-1322.
  • 8. Brosky M. E. (2007), The role of saliva in oral health, Strategies for prevention and management of xerostomia, J Support Oncol, 5(5), 215-225.
  • 9. Bundy K.J. (1994), Corrosion and other electrochemical aspects of biomaterials, Critical Reviews in Biomedical Engineering, 22, 3-4, 139-251.
  • 10. Canay S., Őktemer M. (1992), In vitro corrosion behavior of 13 prosthodontic alloys, Quint Int., 23, 4, 279–87.
  • 11. Chaturvedi T. P. (2009), An overview of the corrosion aspect of dental (titanium and its alloys), Indian J Dent Res, 20 (1), 91-98.
  • 12. Dobrzański L. A., Reimann Ł. (2011), Influence of Cr and Co on hardness and corrosion resistance CoCrMo alloys used on den-tures, J. Achiev. Mater. Manuf. Eng., Vol. 49, 2, 193-199.
  • 13. Dodds M. W. J., Johnson D. A., Yehc Ch. K. (2005), Health bene-fits of saliva: a review, J Dent, 33, 223–233.
  • 14. Grosgogeat B., Reclaru L., Lissac M., Dalard F. (1999), Measure-ment and evaluation of galvanic corrosion between titanium/Ti6Al4V implants and dental alloys by electrochemical techniques and auger spectrometry, Biomaterials, 20, 933-941.
  • 15. Hansen D. C. (2008), Metal corrosion in the human body: the ulti-mate bio-corrosion scenario, The Electrochemical Society, 31-34.
  • 16. Hermawan H., Ramdan D., Djuansjah J. R. P. (2011), Metals for Biomedical Applications, Biomedical Engineering, from: http://www.intechopen.com/books/biomedical-engineering-from-theory-toapplications/metals-for-biomedical-applications.
  • 17. Ige O. O., Umoru L. E., Adeoye M. O., Adetunji A. R., Olorunniwo, O. E., Akomolafe I. I. (2009), Monitoring, Control and Prevention Practices of Biomaterials Corrosion, Trends Biomater. Artif. Organs, Vol. 23, 2, 93-104.
  • 18. Jayaraman A., Cheng E. T., Earthman J. C., Wood T. K. (1997a), Axenic aerobic biofilms inhibit corrosion of SAE 1018 steelthrough oxygen depletion, Appl Microbiol Biotechnol, 48, 11-17.
  • 19. Jayaraman A., Earthman J.C., Wood T.K. (1997b), Corrosion inhibition by aerobic biofilms on SAE 1018 steel, Appl Microbiol Bio-techno,l 47, 62-68.
  • 20. Kaczmarek U. (2007), Treatment of mouth dryness – literature review, Czas. Stomatol. LX, 2, 88-95 (in Polish).
  • 21. Kocjan A., Conradi M. (2010), The corrosion behaviour of austenitic and duplex stainless steels in artyfical body fluids, Materials and Technology, 44, 21-24.
  • 22. Lee A. K., Newman D. K. (2003), Microbial iron respiration: impacts on corrosion processes, Appl Microbiol Biotechnol, 62, 134–139.
  • 23. Liu Y., Wang Q., Song Y., Zhang D., Yu S., Zhu X. (2009), A study on the corrosion behavior of Ce-modified cast AZ91 magnesium alloy in the presence of sulfate-reducing bacteria, Journal of Alloys and Compounds, 473, 550–556.
  • 24. Manivasagam G., Dhinasekaran D., Rajmanickam A. (2010), Biomedical implants: corrosion and its prevention – a review, Recent Patents on Corrosion Science, 2, 40-54.
  • 25. Marciniak J., Paszenda Z. (2005), Biotolerance of metallic bio-materials, Spondyloimplantologia advanced spine treatment system DERO, Wyd. Polska Grupa DERO, Zielona Gora, 133-142.
  • 26. Mareci D., Romas M., Cailean A., Sutiman D. (2011), Electrochem-ical studies of cobalt-chromium-molybdenum alloys in artificial saliva, Revue Roumaine de Chimie, 56, 697-704.
  • 27. Mareci D., Ungureanu G., Aelenei D. M., Rosca J. C. (2007), Electrochemical characteristics of titanium based biomaterials in arti-ficial saliva, Materials and Corrosion, 58, 848-856.
  • 28. Paszenda Z., Walke W., Jadacka S. (2010), Electrochemical inves-tigations of Ti6Al4V and Ti6Al7Nb alloys used on implants in bone burger, Journal of Achievements in Materials and Manufacturing En-gineering, Vol. 38, 1, 24-32.
  • 29. PN-EN ISO 10993-15:2009. Biological evaluation of medical devices, Part 15: Identification and quantification of degradation products from metals and alloys.
  • 30. Rajendran S., Chitradevi P., Johnmary S., Krishnaveni A., Kan-chana S., Christy L., Nagalakshmi R., Narayanasamy B. (2010), Corrosion behaviour of SS 316L in artificial saliva in presence of electral., Zastita Materijala, 51, 149-158.
  • 31. Rantonen P.( 2003), Salivary flow and composition in healthy and diseased adults, University of Helsinki, Helsinki.
  • 32. Reclarua L., Lüthyb H., Eschlera P.-Y., Blattera A., Suszc Ch. (2005), Corrosion behaviour of cobalt–chromium dental alloys doped with precious metals, Biomaterials, 26, 4358–4365.
  • 33. Reza H., Bidhendi A., Pouranvari M.(2011), Corrosion, Study of Metallic Biomaterials In. Simulated Body Fluid, Metallurgia, Vol.17, 13-22.
  • 34. Santonen T., Stockmann-Juvala H., Zitting A. (2010), Review on toxicity of stainless stell, 87s.Helsinki.
  • 35. Sharma M., Kumar A.V.R., Singh N., Adya N., Saluja B. (2008), Electrochemical Corrosion Behavior of Dental/Implant Alloys in Artifi-cial Saliva, JMEPEG, 17, 695–701
  • 36. Surowska B. (2009), Metaliic biomaterials and metal-to-ceramic of dental applications, Wyd. Liber Duo S.C., Lublin.
  • 37. Świeczko-Żurek B. (2009), Biomaterials, Wyd. Politechniki Gdańskiej,151.
  • 38. Unalan F., Aykor A., Bilhan H. (2009), The Galvanic Interaction Between a CoCtMo Alloy, Pure Titanium and Two Different Dental Amalgams with Special Attention on the Area Size, The open Corro-sion Journal, 2, 17-25.
  • 39. Upadhyay D., Panchal M. A., Dubey R. S., Srivastava V. K. (2006), Corrosion of alloys used in dentistry: A review, Materials Science and Engineering: A, 432, 1–11.
  • 40. Wang K. (1996), The use of titanium for medical applications in the USA, Materials Science and Engineering: A, 213 134-137
  • 41. Wataha J. C. (2000), Biocompatibility of dental casting alloys: a review., J Prosthet Dent, 83, 223–34.
  • 42. Zalewska A. K., Waszkiel D., Kowalczyk A. (2007), Saliva as a main component of oral cavity ecosystem, Wiad. Lek., 60, 3-4.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-4c14ed20-fd66-4d4f-ba4c-a8571510c6e7
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.