Tytuł artykułu

Zastosowanie metod modelowania matematycznego do wyznaczania bezpiecznego czasu stosowania rękawic chroniących przed czynnikami chemicznymi

Identyfikatory
Warianty tytułu
EN
Application of the methematical modeling methods to estimate the end-of-service-life of gloves protecting against chemicals
Języki publikacji
PL
Abstrakty
EN
A new approach to determining the end-of-service-life protecting against chemicals made from polymeric materials, which includes the application of mathematical modeling methods is presented in the article. The definition of the end-of-service-life concerns time, after which the polymeric material of protective gloves does not exhibit effective barrier against chemicals at workplace. Based on the review of the literature, factors, which influence on the structural changes of polymeric materials, and are not taken into account in the standard procedure acc. EN 16523-1:2015 (PN-EN 16523-1:2015-05) were characterized in detail.These factors determine the end-of-service-life of protective gloves. The procedure of exploring of functional dependency in mathematical modelling was also presented.
Rocznik
Tom
Strony
23--28
Opis fizyczny
Bibliogr. 31 poz., rys., tab.
Twórcy
autor
  • Centralny Instytut Ochrony Pracy - Państwowy Instytut Badawczy, Zakład Ochron Osobistych, Pracownia Ochron Rąk i Nóg w Łodzi
  • Centralny Instytut Ochrony Pracy - Państwowy Instytut Badawczy, Zakład Ochron Osobistych, Pracownia Ochron Rąk i Nóg w Łodzi
Bibliografia
  • [1] Majchrzycka Katarzyna, Adam Pościk [red.]. 2007. "Dobór środków ochrony indywidualnej". Warszawa: CIOP-PIB.
  • [2] Rozporządzenie Ministra Pracy i Polityki Socjalnej z dnia 26.09.1997 r. w sprawie ogólnych przepisów bezpieczeństwa i higieny pracy (tekst jednolity) Dz.U. 2003, nr 169, poz. 1650 ze zm.
  • [3] PN-EN 16523-1:2015-05 (EN 16523-1:2015) "Wyznaczanie odporności materiału na przenikanie substancji chemicznych - Część 1: Przenikanie ciekłej substancji chemicznej w warunkach ciągłego kontaktu."
  • [4] Wulfhorst B., M. Bock, Ch. Skudlik, W. Wigger-Alberti, S. M. John. 2011. "Prevention of Hand Eczema: Gloves, Barrier Creams and Worker’s Education. W Contact Dermatitis 5th, J. D. Johansen, P. J. Frosch, J. P. Lepoitterin (Eds.), 985-1016. Berlin Heidelber: Springer-Verlag.
  • [5] Packham Chris. 2006. "Gloves as Chemical Protection - Can They Really Work?". Annals of Occupational Hygiene 50 : 545-548.
  • [6] Ogden Trevor. 2010. "Managing Dermal Risk: Moving on From Gloves". Annals of Occupational Hygiene 54 : 131-133.
  • [7] PN-EN 374-1:2005 (EN 374-1:2003) "Rękawice chroniące przed substancjami chemicznymi i mikroorganizmami -- Część 1: Terminologia i wymagania".
  • [8] Chęsy Paulina, Emilia Irzmańska. 2016. "Jak długo używać rękawic ochronnych w narażeniu na substancje chemiczne?". Promotor BHP 9 (16) : 16-21.
  • [9] Vahdat Nader, J. S. Johnson, A. Neidhardt, J. Cheng, D. Weitzman. 1995. "Permeation of Chemicals Trough Glove Box Glove Materials". Applied Occupational and Environmental Hygiene 10 (11) : 943-950.
  • [10] Duncan B., J. Urquhart, S. Roberts. 2005. "Review of Measurement and Modelling of Permeation and Diffusion in Polymers". NPL REPORT DEPC MPR 012.
  • [11] Irzmańska Emilia, Agnieszka Stefko. 2013. "Bezpieczny czas użytkowania rękawic chroniących przed czynnikami mechanicznymi i olejami mineralnymi". Promotor 6 (2-13) : 30-33.
  • [12] Irzmańska Emilia, Katarzyna Dyńska-Kukulska, Magdalena Jurczyk-Kowalska. 2014. "Characteristics of microstructural phenomena occurring on the surface of protective gloves by the action of mechanical and chemical factors". Polimery 59 (2) : 136-146.
  • [13] Irzmańska Emilia, Agnieszka Stefko. 2015. "Simulation method for assessing the end of service life of gloves used by workers exposed to mineral oils and mechanical factors". International Journal of Industrial Ergonomics 47 : 61-71.
  • [14] Irzmańska Emilia, Agnieszka Stefko, Katarzyna Dyńska-Kukulska. 2015. "Factors influencing the end of the service life of protective gloves used in car repair shop: A preliminary report". Archives of Environmental and Occupational Health 70 (2) : 81-90.
  • [15] Klingner Thomas D., Mark F. Boenigner. 2002. "A critique of assumptions about selecting chemical-resistant gloves: a case for workplace evaluation of glove efficacy". Applied Occupational and Environmental Hygiene 17 (5) : 360-367.
  • [16] Mickelsen R. L., M. M. Roder, S. P. Berardinelli. 1986. "Permeation of chemical protective clothing by three binary solvents mixtures". American Industrial Hygiene Association Journal 47 (4) : 236-240.
  • [17] Linnarson A., K. Halvarson. 1981. "Study of the permeation of polymer materials with respect to organic compounds". Sweden Defense Research Facility, Main Division 2, Report 1.
  • [18] Perkins Jimmy L., Arthur D. Tippit. 1985. "Use of three-dimensional solubility parameter to predict glove permeation". American Industrial Hygiene Association Journal 46 (8) : 455-459.
  • [19] Andreasson H., A. Boman, S. Johnsson, S. Karlsson, L. Barregård. 2003. "On permeability of methyl methacrylate, 2-hydroxyethyl methacrylate and triethyleneglycol dimethacrylate through protective gloves in dentistry". European Journal of Oral Science 111 : 529-535.
  • [20] Świdwińska-Gajewska Anna, Małgorzata Kupczewska-Dobecka. 2009. "Metakrylan metylu - Dokumentacja dopuszczalnych wielkości narażenia zawodowego". Podstawy i Metody Oceny Środowiska Pracy 3(61) : 127-158.
  • [21] Krzemińska Sylwia. 2006. "Metoda badania odporności barierowych materiałów na przenikanie mieszanin substancji chemicznych". Bezpieczeństwo Pracy 2 : 18-19.
  • [22] Krzemińska Sylwia. 2005. "Badania odporności błon z wulkanizatów kauczuku butylowego na przenikanie mieszanin rozpuszczalników organicznych". Polimery 50 : 11-12.
  • [23] Chao Keh-Ping, Hsu Ya-Ping, Chen Su-Yi. 2008. "Permeation of aromatic solvent mixtures through nitrile protective gloves". Journal of Hazardous Material 153 : 1059-1066.
  • [24] Evans Paul G., John J. McAlinden, Peter Griffin. 2001. "Personal Protective Equipment and Dermal Exposure". Applied Occupational and Environmental Hygiene 16 (2) : 334-337.
  • [25] Vahdat Nader, Michael M. Bush. 1989. W "Influence of temperature on the permeation properties of protective clothing material". W "Chemical Protective Clothing Performance in Chemical Emergency Response". ASTM STP 1037, American Society for Testing and Materials, Philadelphia.
  • [26] Zellers E. T., R. Sulewski. 1993. "Modelling the temperature dependence of n-Methylpyrrolidone permeation through butyl and natural rubber gloves". American Industrial Hygiene Association Journal 54 (9) : 465-479.
  • [27] Alexy B., R. M. Buchan. 1987. "Temperature as a variable in evaluating the permeability of 1,1,1-Trichloroethane through four types of chemical protective clothing". American Industrial Hygiene Association Journal 48 (2) : 104-109.
  • [28] Phalen Robert N., Wong Kee Wong. 2012. "Chemical resistance of disposable nitrile gloves exposed to simulated movement". Journal of Occupational Environmental Hygiene 9 (11) : 630-639.
  • [29] Program Wieloletni pn. "Poprawa bezpieczeństwa i warunków pracy", etap II, Część A: Program realizacji zadań w zakresie służb państwowych w latach 2011-2013, pt. "Opracowanie metody badania czasu zużycia rękawic chroniących przed olejami mineralnymi i wybranymi czynnikami chemicznymi".
  • [30] Kowalski Bruce R. (Ed.). 1984. "Chemometrics - Mathematics and Statistics in Chemistry". Springer.
  • [31] Brereton Richard G. 2003. "Chemometrics - Data Analysis for the Laboratory and Chemical Plant". John Wiley & Sons Ltd.
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-8af3bd5e-e285-494a-aea6-72ec40073320
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.