Poland’s third largest city, Lodz, underwent rapid industrial and demographic growth in the 19th and 20th centuries, followed by a steep decline over the last three decades. This paper describes how the water supply system has been adapted over the last century to meet these challenges, and in particular how the source of water (surface or underground) and structure of the supply system has been adapted to maintain drinking water quality. The Lodz water supply has been managed since 1925 by the firm Zaklad Wodociagow i Kanalizacji Sp. z o.o. The water supply system was designed by the Englishman William H. Lindley (in 1909), but because of World War I and the global depression that followed work began only in 1934. After World War II further deep wells were constructed, followed by a pipeline network and treatment plant. A 50-kilometre pipeline bringing surface water from the Pilica River was completed in 1955, followed by the Sulejowski Reservoir on the same river (1968–1973). Algal blooms on the reservoir presented a major challenge, and deep wells were turned to as a solution. By 2010 Lodz had 58 deep well intakes, so that in 2013 it was no longer necessary to take taking surface water from the Sulejowski Reservoir.
Projekt łódzkiej sieci wodociągowej, wykonany przez najlepszego europejskiego fachowca W. Lindleya, powstał już w 1909 r. Realizację rozpoczęto w 1934 r., przy współudziale polskiego inżyniera S. Skrzywana. Po II wojnie światowej dokonano wiercenia dalszych studni głębinowych i zbudowano system wodociągowy oraz stację uzdatniania wody. Zbudowano 50 km rurociągu Tomaszów–Łódź (1955 r.), zbiornik retencyjny na Pilicy (1968–1973) i kolejne studnie głębinowe. W 2010 r. istniało już 58 ujęć wód podziemnych dlatego też w 2013 r. zapadła decyzja o rezygnacji z ujmowania wody powierzchniowej z Zalewu Sulejowskiego. Celem pracy było przedstawienie miejsc pobierania wody i struktury sieci wodoci ągowej, której budowa ulegała zmianom w zależności od potrzeb i rozwoju dużego miasta, w powiązaniu z uzyskiwaniem wody pitnej najwyższej jakości. Piecze nad eksploatacją i dystrybucją nieprzerwanie od 1925 r. sprawuje Zakład Wodociągów i Kanalizacji Sp. z o.o. w Łodzi.
Czasopismo
Rocznik
Tom
Strony
1255--1264
Opis fizyczny
Bibliogr. 11 poz., wykr.
Twórcy
autor
- Faculty of Process and Environmental Engineering, Lodz University of Technology, ul. Wólczańska 213, 90–924 Łódź, Poland, phone: +48 42 631 37 88
autor
- Municipal Water and Wastewater Company, 90–133 Łódź, Wierzbowa 52, Poland.
Bibliografia
- [1] Archive and internal documents of the ZWiK, Łódź: Archive of the ZWiK; 1920-2013.
- [2] Regulation of the Minister for Health and Social Welfare dated 4 May 1990 amending the regulation on the standards to be met by water for drinking and for commercial purposes. Journal of Laws 1990, No 35, item 205.
- [3] Regulation of the Minister for Health dated 4 September 2000: On the conditions that should be met by water for drinking and for commercial purposes and water in bathing areas, and the basis for conducting water quality inspections by Health Inspectorate bodies. Journal of Laws 2000, No 82, item 937.
- [4] Regulation of the Minister for Health dated 29 March 2007: On the quality of water intended for human consumption. Journal of Laws 2007, No 61, item 417.
- [5] Regulation of the Minister for Health dated 20 April 2010 amending the regulation on the quality of water intended for human consumption. Journal of Laws 2010, No 72, item 466.
- [6] Świerk D, Szpakowska B. An ecosystem valuation method for small water bodies. Ecol Chem Eng S. 2013:20(2):397-418. DOI: 10.2478/eces-2013-0029.
- [7] Tynan N. Nineteenth century London water supply: Processes of innovation and improvement. The Review of Austrian Economics. 2013:26(1):73-91. DOI 10.1007/s11138-012-0182-8.
- [8] Bruggen B, Borghgraef K, Vinckier C. Causes of water supply problems in urbanised regions in developing countries. Water Res Manage. 2010:24(9):1885-1902. DOI: 10.1007/s11269-009-9529-8.
- [9] Patterson C, Adams J. Emergency response planning to reduce the impact of contaminated drinking water during natural disasters. Frontiers of Earth Sci. 2011:5(4):341-349. DOI: 10.1007/s11707-011-0196-8.
- [10] Chmiel MJ. Metoda luminescencyjna jako alternatywa w badaniach zanieczyszczenia bakteriologicznego wody. Gaz, Woda i Technika Sanitarna. 2012;539-541.
- [11] Goncharuk VV, Kovalenko VF, Zlatskii IA. Comparative analysis of drinking water quality of different origin based on the results of integrated bioassay. J Water Chem Technol. 2012:34(1):61-64. DOI: 10.3103/S1063455X12010092.