EN
This article deals with the subject of simulation of power losses and thermal processes occurring in semiconductors, as illustrated by an example of a DC/DC buck converter. The simulations were performed in PLECS software. The results obtained from the program were compared with measurement results of a laboratory converter model. The physical model is based on the same components as assumed in the simulation. Similarly, the parameters of the transistor control signal were the same. During operation of the converter, the temperature changes were analyzed using a K-type thermocouple. Based on the obtained results of the temperature measurement in the steady state of the converter operation, the correctness of the simulation carried out in the PLECS program was verified and confirmed.
PL
W pracy zbadano wpływ zmiennej rezystywności elektrycznej na nieustalone pole termiczne szynoprzewodu cylindrycznego. Analizę przeprowadzono metodą funkcji Greena. Na tej podstawie wyznaczono długotrwałe prądy dopuszczalne, krzywe rozgrzewu oraz termiczne stałe czasowe modeli układu ze zmiennym i stałym oporem właściwym. Wyniki pozytywnie zweryfikowano metodą elementów skończonych za pomocą modułu matematycznego modelowania programu Comsol Multiphysics.
EN
The influence of the variable electric resistivity on the transient thermal field of a cylindrical bus bar has been analysed in this paper. The Green’s function was used for this purpose. On this basis, the steady state current rating, the heating curves and the thermal time constants of the model of the system with variable and state resistivity were determined. Results were verified with the finite elements method. A mathematical modeling module of the Comsol Multiphysics software was applied for this purpose.
EN
In the article a spatial-temporal heating curve and distribution of the local time constant of the plano-parallel system were determined by the method of states superposition. The heat exchange is characterized by three different coefficients of the heat transfer on a perimeter of the system cross-section. The transient component of the thermal field was found solving the boundary-initial problem for the equation of heat conduction by the separation of variables method. The presented solution can be a mathematical model of the transient thermal field in a rectangular DC busway or in a long dielectric capacitative heated. It was proved that the busway can be approximated by the element of lumped parameters. In opposition to that, long dielectric have to be modeled by the element of distributed parameters. The results were verified by the method of finite elements (program NISA v. 16) and presented in a graphic form.
PL
Za pomocą metody superpozycji stanów w artykule wyznaczono przestrzenno-czasową krzywą rozgrzewu i rozkład lokalnej stałej czasowej układu płasko-równoległego. Wymianę ciepła charakteryzują trzy różne współczynniki jego przejmowania na obwodzie przekroju układu. Składową przejściową pola termicznego uzyskano rozwiązując metodą separacji zmiennych zagadnienie brzegowo-początkowe dla równania przewodnictwa cieplnego. Prezentowane rozwiązanie może stanowić model matematyczny nieustalonego pola termicznego w prostokątnym szynoprzewodzie DC lub w długim dielektryku nagrzewanym pojemnościowo. Wykazano, że szynoprzewód może być aproksymowany elementem o parametrach skupionych. W przeciwieństwie do tego, długi dielektryk musi być modelowany elementem o parametrach rozłożonych. Wyniki sprawdzono za pomocą metody elementów skończonych (program NISA v. 16) i przedstawiono w postaci graficznej.
PL
Przybliżoną wartość termicznej stałej czasowej detektora piroelektrycznego można wyznaczyć z parametrów jego charakterystyki Bodego, jeżeli stosunek n termicznej i elektrycznej stałej czasowej osiąga odpowiednio dużą, niestety bliżej niesprecyzowaną w literaturze, wartość liczbową. W artykule zaprezentowano ścisły opis matematyczny zależności błędu pomiaru termicznej stałej czasowej detektora piroelektrycznego od wartości współczynnika n.
EN
Thermal time constant of the pyroelectric detector is usually determined from the cutoff frequency of his Bode plot. The method can provide good measurement results by assumption that the thermal and electric time constants are significantly different. In the literature there is no more specific suggestions of desired values of the factor n which describes the ratio between the thermal and electrical time constant. As a result of conducted studies the mathematical formula for determining measurement error of the thermal time constant as function of this factor n was obtained.
PL
Na skutek zmiany warunków brzegowych wymiana ciepła w przegrodach budowlanych nie zawsze ma charakter stanu ustalonego. Strumienie ciepła przenikające przez taką przegrodę mogą być kilkukrotnie większe niż w stanie ustalonym. Zatem budynek może mieć o wiele wyższe zapotrzebowanie na energie i wymaga zastosowania większej mocy grzejników niż to wynika z obliczeń normowych. W tym artykule zajmowano się szacowaniem długości trwania stanu nieustalonego po zmianie warunków brzegowych. Analizowano fragment płyty stopu schronu o wymiarach 35x1 m i grubości 0,5 m. Płyta z jednej strony jest chłodzona w powietrzu o temperaturze 8,6 oC z drugiej strony znajduje się wnętrze schronu o temperaturze 20 oC. Wyznaczono czas ostygania z zależności teoretycznej oraz obliczeń numerycznych, przedyskutowano różnice i wyciągnięto wnioski.
EN
As a result of changes in the boundary conditions a heat exchange in the building envelope is not always in a steady state. Heat fluxes penetrating through the wall may be several times greater than the steady state. Thus, the building can have a much higher demand for energy and requires the use of more powerful heater than it results from the standard calculation. This article dealt with estimating the length of the transient state after changing boundary conditions. The analysis portion of the protective celling plate measuring 35x1 m and a thickness of 0,5 m. The plate on the one hand, is cooled in air at a temperature of 8.6 °C, on the other hand is inside the shelter at 20 °C. Period of cooling based on the theoretical and numerical calculations, was obtained then the differences were discussed and conclusions drawn.
EN
The paper describes thermal model of an ASIC designed and fabricated in CMOS 0.7 µm (5 V) technology. The integrated circuit consists of analogue and digital heat sources and some temperature sensors. It has been designed to carry out some thermal tests. During tests thermal resistances, capacities, time constants and convection coefficients for different packages, positions and cooling methods were extracted. The parameters of thermal model were used in simulation to compare results with real-world measurements.
PL
Artykuł opisuje model termiczny układu ASIC zaprojektowanego i sfabrykowanego w technologii CMOS 0,7 µm (5 V). Układ scalony składa się z analogowych i cyfrowych źródeł ciepła oraz czujników temperatury a został zaprojektowany w celu wykonywania testów termicznych. Podczas przeprowadzonych testów zmierzone zostały rezystancja termiczna, pojemność termiczna, termiczna stała czasowa i uogólniony współczynnik konwekcji dla różnych wariantów obudowy, jej położenia i metody chłodzenia. Parametry modelu termicznego zostały użyte w symulacjach w celu porównania wyników z rzeczywistymi pomiarami.
PL
W artykule przedstawiono wyprowadzoną przez autora zależność umożliwiającą wyznaczanie wartości cieplnej stałej czasowej przewodów przy dowolnym sposobie ich ułożenia.
EN
The paper presents a relationship worked out by the author enabling determination of a cables thermal time constant regardless of the manner of its laying.
PL
Przetworniki piezoelektryczne są często wykorzystywane w pomiarach fotoakustycznych. Artykuł przedstawia wstępne wyniki i wnioski z eksperymentów i pomiarów materiału piezoelektrycznego, który był użyty zarówno jako badana próbka, jak i jako detektor wzbudzonego sygnału fotoakustycznego. Częstotliwościowe charakterystyki badanego materiału zostały zdjęte w zakresie od 1 Hz do 10 kHz. Zmierzone charakterystyki wykazują silny wpływ wejściowego stopnia wzmacniacza na amplitudę sygnału w zakresie niskich częstotliwości. Zależność ta wynika z elektrycznej stałej czasowej wzmacniacza oraz cieplnej stałej czasowej badanego materiału.
EN
Piezoelectric sensors are often used as detectors in photoacoustic measurements. The paper presents preliminary results and conclusions from the experiments and measurements of a piezoelectric material that was simultaneously used as both: investigated sample and a sensor of the induced photoacoustic signal. Photoacoustic frequency responses of the investigated piezoelectric material were measured for the frequency range of l Hz to 10 kHz. The measured responses show strong influence of the amplifier input stage on the amplitude of the signal at low frequencies, resulting from the electrical time constant of the amplifier and thermal time constant of the investigated material.
PL
W pracy przedstawiono stanowisko umożliwiające pomiar termicznej stałej czasowej bolometrów. Stanowisko składa się z układu pomiarowego połączonego z cyfrowym oscyloskopem lub analizatorem sygnału i umożliwia pomiar stałej czasowej w zakresie do kilku sekund. Omówiono budowę i działanie opracowanego układu i zaprezentowano wyniki pomiarów oraz przedstawiono kierunki dalszych prac.
EN
A setup for measurement of thermal time constant of bolometers is presented in the paper. Consisting of a circuit connected to a digital oscilloscope or dynamic signal analyzer, this setup allows the thermal time constant to be measured in the range up to few seconds. Design of the circuit and its operation are discussed and results of time constant measurements are presented. Directions of further work are also presented.
PL
Przedmiotem prezentacji jest przedstawienie rezultatów badań cienkowarstwowego bolometru wykorzystującego warstwę z niestechinetrycznych przewodzących, tlenków lantanowo-strontowo żelazowych (La,Sr)FeO₃, LSFO. Przedstawiono sposoby przeprowadzenia pomiarów: rezystancji, temperaturowego współczynnika rezystancji, termicznej stałej czasowej, charakterystyki prądowo-napięciowej oraz parametrów szumowych bolometru. Korzystając z wyników przeprowadzonych pomiarów dokonano doboru punku pracy, dla którego stosunek sygnał/szum osiąga maksimum. Pokazano wpływ kontrolowanego, przyspieszonego starzenia warstw LSFO na ich rezystywność. Pokazano także częstotliwościowe odpowiedzi badanego bolometru na promieniowanie ciała czarnego o różnych temperaturach.
EN
The results of research on a thin-film bolometer made from a conducting layer of non-stoichiometric lanthanum-strontium-iron oxides are presented in the paper. Measurement methods of: current-voltage characteristics, resistance, temperature coefficient of resistance, thermal time constant, and bolometer noise are outlined. Utilizing the measurement results, the operating point yielding the highest signal-to-noise ratio was selected. The influence of controlled, accelerate aging of the LSFO layers on their resistivity is discussed. Response yspectra of the bolometer to the radiation of a blackbody are also presented.