The paper presents an approach to the software implementation of pulse-density modulation (PDM) control for H-bridge series-resonant converters. The formation of pulse-density modulated control signals directly by a microcontroller makes it possible to avoid using many additional chips for the hardware implementation of PDM control. For this purpose, four control patterns and transactions between them are described. Moreover, the features of the organization PDM sequences in the source code of the microcontroller are discussed, and an algorithm for choosing control patterns and preparing timer registers is shown.
PL
W artykule przedstawiono podejście do implementacji programowej sterowania modulacją gęstości impulsów (PDM) dla przekształtników szeregowo-rezonansowych z mostkiem H. Tworzenie sygnałów sterujących o modulowanej gęstości impulsów bezpośrednio przez mikrokontroler umożliwia uniknięcie stosowania wielu dodatkowych układów scalonych do sprzętowej implementacji sterowania PDM. W tym celu opisano cztery wzorce sterowania oraz transakcje między nimi. Ponadto omówiono cechy organizacji sekwencji PDM w kodzie źródłowym mikrokontrolera oraz przedstawiono algorytm wyboru wzorców sterowania i przygotowania rejestrów czasowych.
3
Content available remote Sieci dystrybucyjne o dwukierunkowym przepływie energii
PL
W referacie pokazano, że istotnym źródłem zwiększania napięcia w sieciach podczas generacji energii przez źródła rozproszone jest niesymetria prądów spowodowana jednofazowymi odbiornikami energii elektrycznej. Przesyłanie energii w kierunku sieci przy wzroście napięcia powyżej dopuszczalnego jest niemożliwe i źródła energii są wyłączane, co ogranicza dwukierunkowe działanie sieci. Przestawiono wyniki pomiarów ilustrujące działanie regulatora napięcia połączonego z symetryzacją prądów co umożliwia dwukierunkowy przesyłanie energii linią niskiego napięcia.
XX
The paper shows that an important source of increasing the voltage in networks during energy generation by distributed sources is the asymmetry of currents caused by single-phase electric energy receivers. Transmission of energy towards the grid is impossible when the voltage increases above the allowable limit and energy sources are switched off, which limits the bi-directional grid operation. The measurements are presented illustrating the operation of the voltage regulator with the symmetrization of the currents, which enables the bi-directional transmission of energy.
PL
W artykule przedstawiono kompleksowy napęd elektryczny dedykowany do jednostek pływających. Przedstawione rozwiązanie składa się z silnika elektrycznego, przekładni mechanicznej, falownika, ładowarki, baterii oraz jednostki sterującej. Koncepcja napędu powstała w oparciu o rozeznanie rynku oraz informacji od potencjalnych odbiorców. Funkcjonalność układu napędowego została przebadana w warunkach laboratoryjnych.
EN
The comprehensive electric drive dedicated to watercrafts is presented in this article. The presented solution consists of an electric motor, mechanical transmission, inverter, charger, battery and control unit. The drive concept was created basing on market research and information obtained from potential customers. The functionality of the drive system has been tested in laboratory conditions.
PL
W artykule przedstawiono najważniejsze aspekty neutralizacji zagrożeń pożarowych w domowych instalacjach fotowoltaicznych (PV). Zwrócono uwagę na najsłabsze punkty systemu PV w tym zakresie, a w szczególności poprawność wykonywania złącz MC4, które mogą być przyczyną pożaru. Omówiono również różne rozwiązania alternatywne, a w szczególności koncepcję stosowania nowej generacji mikrofalowników PV. Podano również podstawowe zasady bezpieczeństwa stosowania coraz powszechniejszych magazynów energii. Rozważania przeprowadzono w aspekcie zmieniających się w Polsce przepisów dotyczących budowy systemów PV i mechanizmów wsparcia ekonomicznego tego typu inwestycji.
EN
The paper presents the most important aspects of neutralizing fire hazards in domestic PV systems. Attention was paid to the weakest points of the PV system, in particular, the correctness of making MC4 connectors, which can cause fire. Various alternatives were also discussed, particularly the concept of using a new generation of PV microwaves. The basic safety principles of using more common energy storage are also given. The discussion was carried out on changing regulations in Poland concerning the construction and mechanisms of economic support of PV systems.
EN
Due to its multiple advantages in industrial and grid-connected applications, Multi-Level Inverters (MLIs) have increased in popularity in recent years. To improve the efficiency of a grid-connected PV system's integrated multi-level inverter fractional order PI (FOPI) controllers are used to describe the control process. The control system is made up of three control loops based on FOPI controllers: one for controlling the intermediate circuit voltage (Vdc) and the other two for controlling the direct and quadratic currents (Id, Iq) supplied by the multilevel inverter. The proposed controller parameters (Kp, KI, λ) must be selected in order to increase the efficiency of the multi-level inverter while decreasing the total harmonic distortion (THD) of the output current of the inverter as well as voltage. For this we used three meta-heuristic algorithms (PSO, ABC, GWO). The performance of the three controllers PSO-FOPI, ABC-FOPI and GWO-FOPI controller is compared. The findings showed that GWO-FOPI performs better than the other PSO-FOPI and ABC-FOPI in accuracy and total harmonic distortion THD term. The simulation will be conducted using Matlab/Simulink.
EN
The paper concerns the optimization of a tuned mass damper with inerter (TMDI) based on two strategies, i.e., the minimum amplitude in the resonance peak and minimum area under the frequency response curve. The optimization is based on real, accessible parameters. Both optimization procedures are presented in two steps. In the first one, two parameters of the TMDI are tuned (inertance and damping coefficient), while in the second one, three parameters (mass, inertance, and damping coefficient). We show that both strategies give the optimum sets of parameters and allow the reduction of the amplitude of the damped system.
EN
Reducing the effect of unwanted vibrations is an important topic in many engineering applications. In this paper we describe some recent developments in the area of passive vibration mitigation. This is based on a new device called the inerter which can be exploited in a range of different contexts. In this paper we consider two recent examples; (i) where a flywheel inerter is combined with a hysteretic damper, and (ii) in which a pivoted bar inerter is developed for a machining application. In both cases, experimental test results show that the devices can outperform existing methods.
EN
This paper presents the experimental results of a new proof mass actuator for the implementation of velocity feedback control loops to reduce the flexural vibration of a thin plate structure. Classical proof mass actuators are formed by coil–magnet linear motors. These actuators can generate constant force at frequencies above the fundamental resonance frequency of the spring–magnet system, which can be used to efficiently implement point velocity feedback control loops. However, the dynamics of the spring–magnet system limit the stability and control performance of the loops when the actuators are exposed to shocks. The proof mass actuator investigated in this paper includes an additional flywheel element that improves the stability of the velocity feedback loop both by increasing the feedback gain margin and by reducing the fundamental resonance frequency of the actuator. This paper is focused on the stability and control performance of decentralized velocity feedback control loops.
EN
At present, renewable energy sources such as Photovoltaic (PV) are prevalent because the energy sources are unlimited and free of emissions. One example of its application is as a supply for water pumps. In this application, the value of the power produced by solar cells is very influential, because of the more optimal the power generated by solar cells, the more optimal the water that can be pumped by this water pump. However, PV is a non-linear energy source whose output power changes depending on irradiance and ambient temperature. Therefore we need a method to optimize the power released by the PV. This method is called MPPT (Maximum Power Point Tracking). Using MPPT with conventional algorithms such as Perturb and Observe (P&O) has a slow response and oscillations when in maximum power. In this study, an MPPT will be designed with the Fuzzy Logic Controller (FLC) algorithm to accelerate the system's response to load changes and reduce oscillations that occur when maximum power is available. From the results of research that has been done so as to get the MPPT FLC energy efficiency results with irradiation changes of 98.9% (simulation) or 97.62% (implementation) and load changes of 98.8% (simulation) or 96.51% (application). The use of MPPT FLC, when connected to a Water Pump, has an average total water flow more than without MPPT with a ratio of 1.58: 1 so that the use of MPPT with the FLC algorithm produces better response and energy efficiency.
PL
Obecnie dominują odnawialne źródła energii, takie jak fotowoltaika (PV), ponieważ źródła energii są nieograniczone i wolne od emisji. Jednym z przykładów jego zastosowania jest zasilanie pomp wodnych. W tej aplikacji bardzo ważna jest wartość energii wytwarzanej przez ogniwa słoneczne, ponieważ im bardziej optymalna moc wytwarzana przez ogniwa słoneczne, tym bardziej optymalna jest woda, którą ta pompa może przepompować. Jednak fotowoltaika jest nieliniowym źródłem energii, którego moc wyjściowa zmienia się w zależności od natężenia promieniowania i temperatury otoczenia. Dlatego potrzebujemy metody optymalizacji mocy uwalnianej przez PV. Ta metoda nazywa się MPPT (Maximum Power Point Tracking). Używanie MPPT z konwencjonalnymi algorytmami, takimi jak Perturb i Obserwacja (P&O), ma powolną reakcję i oscylacje przy maksymalnej mocy. W tym badaniu MPPT zostanie zaprojektowany z algorytmem Fuzzy Logic Controller (FLC), aby przyspieszyć reakcję systemu na zmiany obciążenia i zredukować oscylacje, które występują, gdy dostępna jest maksymalna moc. Z wyników badań przeprowadzonych w celu uzyskania wyników efektywności energetycznej MPPT FLC przy zmianach napromieniowania 98,9% (symulacja) lub 97,62% (wdrożenie) i zmianach obciążenia 98,8% (symulacja) lub 96,51% (aplikacja). Użycie MPPT FLC, po podłączeniu do pompy wodnej, ma średni całkowity przepływ wody większy niż bez MPPT ze stosunkiem 1,58:1, dzięki czemu użycie MPPT z algorytmem FLC zapewnia lepszą reakcję i wydajność energetyczną.
EN
The paper presents the comparative analysis of the use a two-level, three-level and five-level voltage source inverter (VSI) for supplying a five-phase synchronous motor with permanent magnets (PMSM). The motor was controlled by Indirect Field Oriented Control (IFOC) with Space Vector Modulation (SVM). Simulation tests showing influence of the inverter topology on the drive system were performed in the Matlab/Simulink environment for various values of the switching frequency - from 1 to 30 kHz. The aim of the presented simulation research is analysis of the prototype five-phase PMSM machine and preliminary development of the power supply system based on multilevel inverters. As a result it will allow to correct determination of the rated parameters of the selected devices (mainly the measurement system and semiconductors). The created model can also be used as part of a larger simulation system, e.g. in an electric vehicle.
PL
W pracy przedstawiona została analiza porównawcza zastosowania dwupoziomowego, trójpoziomowego oraz pięciopoziomowego falownika napięcia (VSI) służącego do zasilania pięciofazowego silnika synchronicznego z magnesami trwałymi. Do sterowania układu napędowego zaimplementowano tzw. sterowanie polowo-zorientowane pośrednie (IFOC) z użyciem modulatora wektora przestrzennego SVM (Space Vector Modulation). Przeprowadzone badania symulacyjne w środowisku Matlab/Simulink zostały wykonane dla różnych wartości częstotliwości kluczowania – od 1 do 30 kHz. Celem prezentowanych badań symulacyjnych jest analiza prototypowej pięciofazowej maszyny PMSM oraz wstępne opracowanie układu zasilania opartego na falownikach wielopoziomowych. W rezultacie pozwoli to na poprawne określenie parametrów znamionowych wybranych urządzeń (głównie układu pomiarowego i półprzewodników). Stworzony model może być również wykorzystany w ramach większego systemu symulacyjnego, np. w pojeździe elektrycznym.
13
Content available remote Augmented PDM for series-resonant inverters
EN
The main disadvantage of a pulse-density-modulated (PDM) voltage-source series-resonant inverter (SRI) is that the amplitude of the SRI output current fluctuates. To reduce the fluctuation, this paper presents an augmented PDM control method for the SRI. The proposed augmented PDM reduces the fluctuation in the amplitude of the SRI output current and requires fewer PDM sequences compared to the irregular PDM, and also provides a more uniform pulse density difference between PDM sequences compared to the inconstant PDM.
PL
Główną wadą falownika z rezonansem szeregowym (SRI) z modulacją gęstości impulsu (PDM) jest to, że amplituda prądu wyjściowego SRI ulega wahaniom. Aby zredukować fluktuację, w niniejszym artykule przedstawiono metodę rozszerzonej kontroli PDM dla SRI. Proponowany rozszerzony PDM zmniejsza fluktuację amplitudy prądu wyjściowego SRI i wymaga mniejszej liczby sekwencji PDM w porównaniu z nieregularnym PDM, a także zapewnia bardziej jednolitą różnicę gęstości impulsów między sekwencjami PDM w porównaniu z niestałym PDM.
PL
Farmy fotowoltaiczne są łączone z siecią elektroenergetyczną poprzez falownik DC/AC i transformator. Komutacja prądu w zaworach falownika generuje w indukcyjnościach rozproszenia impulsy napięcia, które oddziałują na układ izolacyjny uzwojeń transformatora. Skuteczną ochronę izolacji uzwojeń transformatora przed przepięcia stanowią filtry tłumiące. Mogą to być kondensatory bądź warystory. Filtr w sposób znaczący poprawia warunki dielektryczne izolacji uzwojenia transformatora.
EN
The solar farms are connected to the electricity grid through a DC / AC inverter and a transformer. The current commutation in the inverter valves generates voltage pulses in the leakage inductances, which act on the insulation system of the transformer windings. Suppression filters provide effective protection of the transformer winding insulation against overvoltage. These can be capacitors or varistors. The filter significantly improves the dielectric conditions of the transformer winding insulation.
16
PL
Wpracyprzedstawionobudowę trójfazowegoprzemiennika częstotliwości zmożliwościąwyboru typu modulacji PWM oraz płynną zmianą częstotliwości sygnału modulowanego.Wpraktyczny sposób zrealizowano różne algorytmy sterowania falownikaw tymsamymukładzie sprzętowym zwykorzystaniemprocesora STMARMCortexM3. ZastosowaniemodulacjiTHIPWMpozwoliło zmniejszyć zawartośćharmonicznychw sygnalewyjściowymi efektywniewykorzystaćmożliwości źródła zasilania. Układ posiada możliwość wyboru jednego z dwóch algorytmów sterowania skalarnego, z opcją kompensacji wpływu rezystancji stojana na moment obrotowy wału silnika w początkowym zakresie charakterystyki sterowania liniowego przy stałym stosunku napięcia do częstotliwości. Badania potwierdziły, że najkorzystniejszym typem modulacji PWM w tym układzie jest modulacja jednobiegunowa dwubrzegowa.Wykorzystanie metodyTHIPWM, skutkowało zyskiem amplitudy podstawowej harmonicznej napięcia wyjściowego dla trójfazowego trybu pracy falownika względem metody SPWM. Uzyskano także odpowiednią precyzję kroku regulacji częstotliwości, a rezultaty badań potwierdziły funkcjonalność przemiennika.
XX
The paper presents the construction of a three-phase frequency converter with the possibility of choosing the type of PWM modulation and a smooth change of the frequency of the modulated signal. In a practical way, various inverter control algorithms were implemented in the same hardware system using the STM ARM Cortex M3 processor. The use of THIPWM modulation allowed to reduce the harmonic content in the output signal and effectively use the possibilities of the power source. The system can choose one of two scalar control algorithms, with the option of compensation for the influence of the stator resistance on the motor shaft torque in the initial range of the linear control characteristic at a constant voltage to frequency ratio. The research confirmed that the most advantageous type of PWM in this system is unipolar double-edge modulation. The use of the THIPWM method resulted in a gain in the amplitude of the fundamental harmonic of the output voltage for the three-phase inverter operation mode compared to the SPWM method. The appropriate precision of the frequency control step was also obtained, and the test results confirmed the functionality of the converter.
EN
In this paper synchronous reference frame (SRF) control strategy based on a self-tunable fuzzy inference system (STFIS) is proposed to control a four-leg transformerless inverter, is presented. The single-stage inverter is controlled to achieve high performance from the PV system without using any maximum power point technique (MPPT), to inject power into the grid, and to improve the power quality, simultaneously. A Fuzzy controller based on an on-line optimization of a zero-order Takagi-Sugeno fuzzy inference system (FIS) by a back propagation-like algorithm is applied to minimize a cost function that is made up of a quadratic error term and a weight decay term that prevents excessive growth of DC-link and PCC. A detailed design of the STFIS controller parameters is given in detail. Furthermore, a comparison between classical PI and STFIS controllers is provided. The performance test of the proposed single-phase configuration and its control strategies are realized under the presence of severe conditions using Matlab/Simulink.
PL
W artykule przedstawiono strategię sterowania synchroniczną ramką odniesienia (SRF) w oparciu o samostrajalny system wnioskowania rozmytego (STFIS) do sterowania falownikiem beztransformatorowym. Falownik jednostopniowy jest sterowany w celu uzyskania wysokiej wydajności systemu fotowoltaicznego bez stosowania techniki maksymalnego punktu mocy (MPPT), jednoczesnego wprowadzania mocy do sieci i poprawy jakości energii. Sterownik Fuzzy oparty na optymalizacji on-line systemu wnioskowania rozmytego Takagi-Sugeno (FIS) zerowego rzędu za pomocą algorytmu przypominającego propagację wsteczną jest stosowany w celu zminimalizowania funkcji kosztu, która składa się z kwadratowego składnika błędu i wagi zaniku, który zapobiega nadmiernemu wzrostowi łącza DC i PCC. Szczegółowo podano projekt parametrów sterownika STFIS. Ponadto przedstawiono porównanie między klasycznymi sterownikami PI i STFIS.
EN
In the paper an economic, ecological and energy analysis of a home photovoltaic on grid installation was presented. The increase in ecological awareness of the Polish society contributes to the continuous growth of interest in green energy. However, many people haven’t been aware of the ecological, economic and energy benefits of photovoltaic installations yet, so the following analysis is made. The analysis concerns a photovoltaic installation with a capacity of 3.96 kWp located in Ościęciny near Włocławek. The photovoltaic installation consists of 11 monocrystalline panels with a power of 360 Wp, a 4 KTLM Sofar Solar inverter and other necessary components. The first part presents basic issues related to photovoltaic installations. Parameters related to the proper functioning of the photovoltaic installation were replaced. The analysis of the literature will help to understand the essence of the proper functioning of the photovoltaic installation. In the practical part, an analysis of a selected home photovoltaic installation was carried out. Based on the available data, it has been calculated that the installation will have a payback period of over 9 years. The photovoltaic installation will produce approximately 3 582.61 kWh of electricity and will contribute to the reduction of 70 tons of carbon dioxide during the entire operation.
19
Content available remote Falownik serii SX1000 zasilający silnik wrzecionowy wysokoobrotowy 400 Hz
PL
W roku 2015 firma Sanyu Sp. j. wprowadziła nowy produkt. Jest nim przemiennik częstotliwości serii SX1000. Poświęciliśmy już wiele artykułów opisujących właściwości tego falownika na łamach miesięcznika „Napędy i Sterowanie”. Doczekał się on już w 2020 roku nowej wersji nazwanej SX1000PLUS.
PL
W polskich warunkach klimatycznych panele fotowoltaiczne w praktyce nie osiągają mocy nominalnej wyznaczonej w warunkach STC (E = 1000 W/m2; AM 1,5; T = 25°C). Typowe warunki natężenia promieniowania słonecznego w bezchmurny dzień to wartość z zakresu (800–900) W/m2. Jest to wartość o (10–20)% niższa od wartości, w której badane są panele. Położenie geograficzne Polski powoduje, że większość energii dostarczanej przez słońce mieści się w zakresie niskiego natężenia, wynoszącego (100–600) W/m2. Dla uzysku energetycznego nie bez znaczenia jest kąt nachylenia paneli PV oraz kąt odchylenia od południa.