Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  anode slimes
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Processing of copper anode-slimes for extraction of metal values
EN
Processing of anodic slimes from an Egyptian copper electrorefining plant, exhibiting high contents of copper, lead, tin and silver has been presented. The proposed hydrometallurgical process consists of two leaching stages for extraction of copper with H2SO4 – O2 and silver with thiourea – Fe3+. Pyrometallurgical treatment of the leaching solid residue for production of Pb-Sn soldering alloy was proposed. Parameters affecting both the leaching and smelting stages were studied.
PL
Opisano przeróbkę szlamów anodowych pochodzących z egipskiego zakładu elektrorafinacji szlamów. Szlamy te posiadają wysoką zawartość miedzi, ołowiu, cyny i srebra. Zaproponowano proces hydrometalurgiczny składający się z dwóch etapów ługowania, czyli ekstrakcji miedzi za pomocą H2SO4–O2 oraz srebra w układzie z tiomocznikiem i Fe+3. Zaproponowano także pirometalurgiczny przerób pozostałości po ługowanie w celu otrzymania stopu Pb-Sn. Przebadano parametry wpływające na procesy ługowania i wytopu.
EN
Palladium and platinum contents in anode slimes at the parts per million (ppm) concen-tration level have been determined by the flame absorption atomic spectrometry (FAAS). Procedure of the sample preparation for analysis had to include the stage of matrix sepa-ration, or Pd and Pt precipitation, because of low amounts of these elements in the slimes. Selective leaching of the (Ag, Pb) matrix in diluted nitric acid with an addition of tartaric acid enabled separation of about 70 % of the sample mass with no loss of both elements. Precipitation of Pd and Pt by the tin(II) chloride solution reduction with the use of the ma-trix components (Se, Au and Te) as a carrier confirmed the accuracy of the results ob-tained by previously assumed procedure. The anode slimes analysis was also made at independent laboratory by the ICP-AES method after Pd and Pt separation by the fire as-say, cupellation and dissolution of the dore\ Good agreement between the Pd and Pt de-termination results obtained by various methods has been found. Relative standard deviations for the precious metals determination results by the devised procedure were of the order of a few percent.
PL
Zawartość Pd, Pt na poziomie ppm w szlamach anodowych oznaczono za pomocą płomieniowej absorpcyjnej spektrometrii atomowej (FAAS). Procedura przygotowania próbek do analizy musiała obejmować etap oddzielania matrycy lub wydzielania Pd, Pt ze względu na poziomy występowania tych pierwiastków. Selektywne ługowanie mat-rycy (Ag,Pb) w rozcieńczonym roztworze kwasu azotowego z dodatkiem kwasu wino-wego, pozwoliło na usunięcie około 70% masy próbki bez strat analitów. Natomiast redukcyjne wydzielenie Pd, Pt roztworem chlorku cyny (II) przy wykorzystaniu skład-ników matrycy (Se, Au, Te) jako nośnika, potwierdziło dokładność otrzymanych wyni-ków według przyjętej wcześniej procedury. Wykonano również analizę szlamów anodowych w niezależnym laboratorium metodą ICP-AES po wydzieleniu metodą ogniową Pd, Pt, kupelacji i roztworzeniu metalu dore'. Uzyskano dobrą zgodność wyników oznaczania Pd i Pt różnymi metodami. Względne odchylenia standardowe oznaczeń metali szlachetnych przyjętą procedurą pozostają na poziomie kilku procent.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.