EN
An adsorber in which sorption processes occur is one of the key components of an adsorption chiller. Precise real-time monitoring of and supervision over these processes are particularly important to ensure their proper execution. The article describes the experimental stand used for the measurement of the adsorber’s operating parameters and analyses pressure measurement uncertainties, taking into account the impact of the temperature on the test system filled with the adsorbent in the form of silica gel, while concurrently considering the influence of other factors (e.g. the environment, the A/A, and A/D conversion, or data processing) on measurement uncertainties. A complex analysis of uncertainties was carried out, including the results of the statistical analysis of the measurement data obtained from long-term experimental tests of the object and the uncertainties of the pressure measuring chain by the type B method, involving the consideration of interactions between the system components and the temperature impact on the propagation of uncertainties. As part of the analysis, the characteristic stages of the data collection and processing operations related to the sampling rate and measurement intervals were separated. The article presents the prototype test stand and original pressure measurement system for the verification of a single-bed adsorber working below 10 hPa.The novel construction of a single-bed adsorber was used as a test object. Furthermore, in this paper, the developed algorithm of the research method implemented in the system was discussed and positively verified.
EN
Thermal conductivity in the boundary layer of heat exchange surface is the crucial parameter of adsorption process efficiency which occurs in the adsorption bed. In order to improve heat transfer conditions in the adsorption chiller, novel constructions of adsorption beds are currently investigated. The porous structure of the sorbent layer causes low thermal conductivity in the adsorption bed. One of the methods to improve heat transfer conditions is a modification of porous media bed structure with glue which is characterized with higher thermal conductivity. The optimum parameters of sorbents and glues to build the novel coated construction, in terms of improving the chiller Coefficient of Performance (COP) were defined in (Grabowska et al. 2018a). The paper implements fuzzy logic approach for predicting thermal conductivity of modified porous media layers. The developed model allows determination of the sorbent layer thermal conductivity based on various input parameters: arithmetic average of particle distribution d, density ρ and thermal diffusivity k. The data from empirical research was used to build up the model by fuzzy logic methods.
PL
W artykule zaprezentowano analizę technicznych możliwości wykorzystania ciepła dostarczanego w okresie letnim przez miejską sieć ciepłowniczą do napędu sorpcyjnych agregatów ziębniczych. Analizę uzupełniono obliczeniami wskaźników ekonomicznych i ekologicznych przypadku zastosowania takiego urządzenia do chłodzenia budynku biurowego w realiach krakowskiej sieci ciepłowniczej. W obliczeniach wykorzystano charakterystyki produktów dostępnych na rynku oraz uwzględniono różne warianty sterowania wydajnością odpowiednio do aktualnego obciążenia chłodniczego obliczanego dla interwałów godzinowych za pomocą autorskiego modelu obliczeniowego. Proponowany system został porównany z tradycyjnym rozwiązaniem chłodzenia za pomocą agregatu sprężarkowego ze skraplaczem chłodzonym powietrzem w zakresie zapotrzebowania na energię końcową i pierwotną, emisji CO2 oraz bezpośrednich kosztów eksploatacyjnych przy spełnieniu tych samych wymagań ilościowych i jakościowych przez obydwa systemy.
EN
The article presents an analysis of the technical possibilities of the use of heat supplied in the summer by the municipal district heating network to drive sorption type refrigeration units. The analysis is supplemented with calculations of economic and environmental indicators based on case study of use such a chiller for cooling an office building in the conditions of Krakow’s district heating network. The study was based on real characteristics of the products available on the market, and various options of capacity control have been considered, adequate to the current cooling load computed for hourly intervals, by using an original author's calculation model, presented in the previous papers. The system proposed has been compared with traditional cooling solution using a compressor type water chiller with air-cooled condenser in terms of final and primary energy demands, CO2 emissions and direct operating costs and subject to the same qualitative and quantitative requirements for both systems.
EN
This paper presents the possibility of reducing the demand for nonrenewable primary energy for buildings using a new conceptual adsorption system of cooling and heating supplied by solar energy. Moreover, the aim of this study is to shorten the payback time of investment in the standard adsorption cooling system through its integration with the heating system. Research has been carried out for an energy-efficient medium-sized single-family building with a floor area of 140 m 2 and a heat load of 4.2 kW and cold load of 4.41 kW. It has been shown that the use of an adsorption system of cooling and heating supplied by solar energy decreased the demand for nonrenewable primary energy by about 66% compared to the standard building that meets the current requirements.
5
Content available remote On adsorption of water vapor on silica gel
EN
The aim of this work is to present the results of studies on heat and mass transfer in an adsorber, which is the main part of an adsorption chiller. The paper refers to adsorption of water vapor on silica gel grains. Adsorbent grains were coated on the outer surface of a copper pipe. The influence of grains diameter and flow rate of the gas phase on process intensity was considered.
PL
Celem niniejszej pracy jest zaprezentowanie wyników badań dotyczących przenoszenia ciepła i masy w adsorberze stanowiącym podstawową część adsorpcyjnego urządzenia chłodniczego. Praca dotyczy adsorpcji pary wodnej na silikażelu. Ziarna silikażelu były naniesione na zewnętrzną powierzchnię miedzianej rurki. Badano wpływ wielkości ziaren oraz natężenia przepływu gazu na intensywność procesu.
EN
This paper is devoted to application of adsorption process for cooling power generation in a cooling devices. Construction and working principle of a water-silica gel adsorption chiller has been presented and the basic refrigeration cycle has been discussed. The article outlines behavior of a single-stage adsorption system influenced by changes in cycle time. The effect of cycle time and inlet chilled water temperatures on the main system performance parameters has been analysed.
PL
W artykule przedstawiono badania możliwości zapewnienia komfortu cieplnego dla pomieszczenia o kubaturze 40 m3, poprzez zastosowanie adsorpcyjnego systemu chłodzenia zasilanego energią promieniowania słonecznego. Chłód był wytwarzany przez adsorpcyjną wytwornicę wody lodowej, zasilaną energią z płaskich kolektorów słonecznych. Przedstawiono również badania eksperymentalne warunków pracy AWWL. Rzeczywista wartość współczynnika wydajności chłodniczej COP adsorpcyjnej wytwornicy wody lodowej wyniosła 0,27, a rzeczywista całkowita sprawność adsorpcyjnego systemu chłodzenia wyniosła 0,23. Na podstawie uzyskanych wyników badań stwierdzono, że w warunkach klimatycznych Polski można efektywnie wykorzystać adsorpcyjny system chłodzenia w celu utrzymania warunków komfortu cieplnego w miesiącach, w których występuje zapotrzebowanie na chłód.
EN
In the current article, research on the possibilities for ensuring thermal comfort in a room of 40 m3 in volume, through the use of an adsorption cooling system supplied by solar energy is presented. Cooling was attained by an adsorption ice water generator (AIWG) that was supplied by energy from flat-plate solar collectors. Experiments on the AIWG working conditions are also presented. The real value of the cooling efficiency of the COP coefficient for the adsorption ice water generator was 0,27, and the real global efficiency of the adsorption cooling system was 0,23. On the basis of the results, it was assumed that, in climate conditions typical for Poland, it is possible to effectively use the adsorption cooling system to keep a constant level of thermal comfort during months in which there is a demand for cooling.
EN
The article summarizes research on the possibilities for ensuring thermal comfort through the use of an adsorption cooling system supplied by solar energy. The main goal was to ensure an adequate level of cooling in a referential room of 40 m3 in volume. Cooling was attained by an adsorption ice water generator (AIWG) that was supplied by energy from flat-plate solar collectors. A testing stand was composed of four modules, each of them being designed for: solar radiation energy generation, accumulation, transfer and use, respectively. AIWG characteristics, i.e. the distribution of temperature and pressure as a function of time, the dependence of the AIWG cooling power and the temperature of the heating medium on the initial evaporator temperature, the dependence of the demand for thermal power and the AIWG cooling power on the initial evaporator temperature and the dependence of the AIWG refrigerating efficiency coefficient as a function of heating medium temperature, were also provided.
9
Content available remote Research on solar adsorption cooling system
EN
In the current paper research on possibilities for ensuring a thermal comfort through usage of an adsorption cooling system supplied by solar energy has been presented. The main thesis was to ensure an adequate level of coldness in a referential room of a 30 m3 cubature. The coldness was generated by an adsorption ice water generator, supplied by energy coming from flat-plate solar collectors. Experiments on AIWG work conditions and an analysis of possibilities of usage of solar energy in a region of Czestochowa (Poland) for supplying the adsorption cooling system have also been presented. A real value of a cooling efficiency of a COP coefficient for the adsorption ice water generator was 0.27, and a real global efficiency of the adsorption cooling system was 0.23. On the basis of received results it was assumed that in a climate conditions typical for Poland it is possible to effectively use the adsorption cooling system in order to keep a constant level of the thermal comfort during all months in which there is a demand for coldness, i.e. between April and October.
PL
W artykule przedstawiono badania możliwości zapewnienia komfortu cieplnego poprzez zastosowanie adsorpcyjnego systemu chłodzenia zasilanego energią promieniowania słonecznego. Głównym założeniem było zapewnienie pokrycia zapotrzebowania na chłód dla pomieszczenia referencyjnego o kubaturze 30 m3. Chłód był wytwarzany przez adsorpcyjną wytwornicę wody lodowej, zasilaną energią z płaskich kolektorów słonecznych. Przedstawiono również badania eksperymentalne warunków pracy AWWL oraz dokonano analizy możliwości wykorzystania energii promieniowania słonecznego na terenie Częstochowy (Polska) do zasilania adsorpcyjnego systemu chłodzenia. Rzeczywista wartość współczynnika wydajności chłodniczej COP adsorpcyjnej wytwornicy wody lodowej wyniosła 0.27, a rzeczywista całkowita sprawność adsorpcyjnego systemu chłodzenia wyniosła 0.23. Na podstawie uzyskanych wyników badań stwierdzono, że w warunkach klimatycznych Polski można efektywnie wykorzystać adsorpcyjny system chłodzenia w celu utrzymania warunków komfortu cieplnego we wszystkich miesiącach, w których występuje zapotrzebowanie na chłód, tj. od kwietnia do października.
10
Content available remote A concept for a solar adsorption cooling system
EN
In the current paper a possible usage of sorption cooling systems, seen as important factor for utilization of low parameters thermal energy (60÷90°C), has been investigated. A list of equations for designing of installations using solar radiation energy for supplying an adsorption ice water generator AIWG has been presented. A concept for an adsorption cooling system consisting of four following modules: generating, accumulating, transmitting and using the solar radiation energy has also been presented. Such parameters as: pressure, temperature, cooling power, thermal power demand and a coefficient of cooling efficiency COP, needed for operation of the adsorption adsorption ice water generator with a cooling power of 0.5 kW, have also been shown. Additionally, an impact of atmospheric conditions variation on operation of the cooling systems and keeping a state of a thermal comfort in a room has also been investigated.
PL
W artykule rozważono zastosowanie sorpcyjnych układów chłodniczych jako istotnego czynnika wykorzystującego energię termiczną o niskich parametrach 60-90°C. Przedstawiono zestaw równań dla zaprojektowania instalacji wykorzystującej energię promieniowania słonecznego do napędu adsorpcyjnej wytwornicy wody lodowej. Zaprezentowano koncepcję adsorpcyjnego systemu chłodzenia składającego się z czterech modułów: wytwarzania, akumulacji, przesyłu i wykorzystania energii promieniowania słonecznego. Przedstawiono również parametry pracy adsorpcyjnej wytwornicy wody lodowej o mocy chłodniczej 0.5 kW, tj. ciśnienia, temperatury, moc chłodniczą, zapotrzebowanie na moc cieplną i współczynnik wydajności chłodniczej COP. Dodatkowo rozważony został wpływ zmienności warunków atmosferycznych na pracę systemu chłodzenia oraz na zachowanie komfortu cieplnego w pomieszczeniu.
PL
W niniejszym artykule podjęto tematykę dotyczącą systemów klimatyzacji budynków zasilanych energią promieniowania słonecznego, przetworzonego do postaci użytkowej poprzez konwersję fotowoltaiczną i konwersję fototermiczną. Przedstawiono korzyści płynące z zastosowania słonecznych systemów klimatyzacji oraz przeanalizowano możliwości ich zastosowania. Zaprezentowano przykładowy system klimatyzacji z wykorzystaniem adsorpcyjnego urządzenia chłodzącego zasilanego energią promieniowania słonecznego przetwarzanego za pomocą kolektorów słonecznych. Zaprezentowano standardową budowę adsorpcyjnej wytwornicy wody lodowej. Dodatkowo została przedstawiona sytuacja na europejskim rynku systemów klimatyzacji słonecznej.
EN
In this article systems of the air-conditioning of buildings with the solar energy utilization were described. There was also presented a demonstration system of the air- conditioning with using the solar driven adsorption chiller. Benefits coming from applying solar systems to the air-conditioning were shown. A standard structure of the adsorption chiller was presented. Energy problems in European Union countries were also considered.