PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Investigations of real conditions properties of the biomedical electrodes with integrated electrode contact quality monitoring system for recording electrocardiographic signals

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Badania właściwości układu elektrod biomedycznych z ciągłą kontrolą stanu kontaktu w rzeczywistych warunkach rejestracji sygnałów elektrokardiograficznych
Języki publikacji
EN
Abstrakty
EN
The results of investigations of the metrological properties of the system of 4 biomedical electrodes with the continuous control of the contact quality, are presented in the hereby paper. Investigations were performed under real conditions of measuring the electrocardiographic signals of humans, at the application of the typical ECG instrumentation. Due to the performed experiments the conformity of the electrocardiographic signals obtained by means of the standard gel electrodes glued to the body and the ones obtained by means of the electrodes with continuous control of the contact quality, was confirmed.
PL
W artykule przedstawiono wyniki badań właściwości metrologicznych układu 4 elektrod do pomiaru sygnałów elektrokardiograficznych człowieka z ciągłą kontrolą stanu kontaktu, przy wykorzystaniu typowej aparatury EKG. Potwierdzono zgodność zapisów sygnałów EKG wykonanych za pomocą standardowych elektrod żelowych przyklejanych do ciała oraz przy zastosowaniu elektrod z ciągłą kontrolą stanu kontaktu.
Rocznik
Strony
55--58
Opis fizyczny
Bibliogr. 17 poz., rys., wykr.
Twórcy
autor
  • AGH University of Science and Technology, Department of Measurement and Electronics, Av. Mickiewicza 30, 30-059 Krakow
autor
  • AGH University of Science and Technology, Department of Measurement and Electronics, Av. Mickiewicza 30, 30-059 Krakow
Bibliografia
  • [1] Augustyniak P., Przetwarzanie sygnałów elektrodiagnostycznych, Uczelniane Wydawnictwa Naukowo-Dydaktyczne AGH, Kraków, (2001)
  • [2] Huclova S., Erni D., Froehlich J., Modeling and validation of dielectric properties of human skin in the MHz region focusing on skin layer morphology and material composition, J. Phys. D: Appl. Phys., 45 (2012), 025301
  • [3] Lin Ch.-T., Liao L.-D., Liu Y.H., Wang I-J., Lin B.S., Chang J.Y., Novel dry Polymer foam electrodes for long-term EEG measurement, IEEE Transactions on Biomedical Engineering, vol. 58 (2011), no 5, 1200-1207
  • [4] Pilawski A. (red.), Podstawy Biofizyki, PZWL, 1977
  • [5] McAdams E.T., Jossinet J., Lackermeier A., Risacher F., Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography, Medical & Biological Engineering & Computing, 34 (1996), 397-408.
  • [6] Chi M. Y., Jung T.-P., Cauwenberghs G., Dry-Contact and noncontact biopotential electrodes: Methodological review, IEEE Reviews in Biomedical Engineering, vol.3 (2010), 106- 119
  • [7] Ichida S., et al., Biomedical electrode, Patent WO 2014/ 007307 (2014)
  • [8] Livnech A., Granov E., Granov I., Biomedical electrode assembly, Patent WO 2013/ 121415 (2013)
  • [9] Netherly S.G., Knudson O.B., Method and apparatus for controlling contact of biomedical electrodes with patient skin, Patent US 2001/ 6171304 B1 (2001)
  • [10] Herlerkson E.C., ECG electrode contact quality measurement system, Patent US 2011/ 8086300 B2 (2011)
  • [11] Marszałek Z., Gawędzki W. , Nowa metoda monitoringu stanu kontaktu elektrody biomedycznej ze skórą pacjenta, Przegląd Elektrotechniczny, 5 (2014), 94-97
  • [12] Marszałek Z., Gawędzki W., Sposób monitorowania stanu kontaktu elektrody biomedycznej ze skórą pacjenta. Zgłoszenie wynalazku PL 406862, Biuletyn UP RP, nr 15 (2015), 3
  • [13] Marszałek Z., Gawędzki W., i in.: Badania wpływu układu monitorowania stanu kontaktu elektrody biomedycznej ze skórą pacjenta na mierzony sygnał elektrokardiograficzny. Przegląd Elektrotechniczny, nr 5 (2015), 72-75
  • [14] Marcos C., Sanchez Pena J., Torres J., Isidro Santos J., Temperature-frequency converter using a liquid crystal cell as a sensing element, Sensors, no. 3 (2012), 3204-3214
  • [15] Gawędzki W., Pomiary elektryczne wielkości nieelektrycznych. Wydawnictwa AGH, Kraków (2010)
  • [16] NI 6341 DAQ Card, User’s Manual (2007) www.ni.com
  • [17] NI LabVIEW 2015 Development Systems, www.ni.com
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-ffc900c4-25ce-491d-b1b7-20e8fbdf5932
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.