PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Patellar tracking in the total knee joint replacement model with patellar retinaculum

Identyfikatory
Warianty tytułu
CS
Pohyb pately v modelu totalni nahrady kolenniho kloubu s patelarnim retinaculem
Konferencja
International Seminar of Applied Mechanics (15 ; 17-19.06.2011 ; Wisła, Poland)
Języki publikacji
EN
Abstrakty
EN
The study aims to identify the key points affecting the patello-femoral joint stability and stress pressure distribution. The finite element model of the knee joint with structures supplying patellar retinaculum is used. The femoral component is rotated along the mechanical axis for 5 degrees both medially and laterally. The stress pressure distribution is analyzed within patello-femoral joint during gait cycle.
CS
Cilem teto prace je urćeni klicovych faktom, ktere ovlivnuji stabilitu patelo-femoralniho kloubniho spojeni. Dalśim cilem je urćeni rozłożeni napeti v tomto spojeni. Pro uvedenou analyzu je poużit drive definovany konećneprvkovy model kolenniho kloubu doplnćny o patelarni retinaculum. Pfidany dalsi ćtyfi vazy ćesky, dva vazy k femuru a dva vazy k tibii. Pfi analyze je kondylar twist uhel nulovy a tibialni plato nahrady je polożeno kolmo na mechanickou osu nohy (fyziologicky spravne nasazena totalni kolenni nahrada). Femoralni ćast nahrady je potom otaćena kołem mechanicke osy o 5 stupnu jak v medialnim, tak i v lateralnim smeru. Nakonec je provedena analyza rozłożeni napeti na patelofemoralnim kloubu behem chuze.
Słowa kluczowe
Rocznik
Tom
Strony
29--34
Opis fizyczny
Bibliogr. 11 poz.
Twórcy
autor
  • The University of West Bohemia, Faculty of Applied Sciences, Department of Mechanics
autor
  • The University of West Bohemia, Faculty of Applied Sciences, Department of Mechanics
autor
  • The University of West Bohemia, Faculty of Applied Sciences, Department of Mechanics
autor
  • The University Hospital in Pilsen. Clinic for Orthopaedics and Traumatology of Locomotive organs
autor
  • The University Hospital in Pilsen. Clinic for Orthopaedics and Traumatology of Locomotive organs
Bibliografia
  • 1 Berger R. A., Crosett L. S. et al: Malrotation causing patellofemoral complications after total knee arthroplasty - Clinical orthopedaedics and related research, 1998, 356: 144. 153.
  • 2. Kren J., Pokorny J„ Koudela K.: Model of the total knee joint replacement. In Modelling and optimization of physical systems. Gliwice: Wydawnictwo Katedry Mechaniki Stosowanej, 2009, s. 81-84.
  • 3. Jansova M„ Kren J., Pokorny J., Koudela K., Koudela K. jr.: Patellar tracking in the total knee joint replacement model. Gliwice: Wydawnictwo Katedry Mechaniki Stosowanej, 2010, s. 37-40.
  • 4. Kockova H., Jansova M.: Model dolnich konćetin se zamefenim na kolenni kloub. In: Proceeding to Computational Mechanics, 2004: 213-216.
  • 5. Kren, J.; Hyncik, L.: Stability of proximal femur nail fixating per-trochanteric fracture. Proceeding of Computational Mechanics, 2002, pp. 219-224.
  • 6. Jansova M., Hyncik L., Horak M., Kfen, J.: Total knee replacement model, Proceeding of Computational Mechanics, 2004.
  • 7. Kfen J., Hyncik L., Rehounek L.: Modelling of interaction between femur and PFN. Proceeding of Computational Mechanics 2001, pp. 141-146.
  • 8. Pokorny J.: The patellofemoral joint and the total knee replacement, Proceeding of Applied and Computational Mechanics 2007, pp. 595-602.
  • 9. Burstein, A. H. et al.: Aging of bone tissue: Mechanical properties, J. Bone Joint Surgery A 58, pp. 82., 1976
  • 10. Haug, E.; Choi, H. Y.; Robin, S.; Beaugonin, M.: Human models for Crash and Impaci imulation, Special Volume of Handbook of Numerical Analysis, vol. XII, Editor- P.G.Ciarlet, pp. 231-670, 2004.
  • 11. Ciarelli, M. J. et al: Experimental determination of the orthogonal mechanical properties, density, and distribution of human trabecular bone from the major metaphyseal regions utilizing material testing and computed tomography. Trans. Orthop. Res. Soc., 42,1991.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-fd0c9bee-d485-42c8-b70d-02c0a936258c
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.