Performance evaluation of a rectifi er column using gamma column scanning

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
International Conference on Applications of Radiation Science and Technology (ICARST-2017) (24-28 April 2017 ; Vienna, Austria)
Języki publikacji
EN
Abstrakty
EN
Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.
Czasopismo
Rocznik
Strony
285--287
Opis fizyczny
Bibliogr. 4 poz., rys.
Twórcy
autor
  • Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646
  • Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646
autor
  • Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646
autor
  • Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646
  • Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646
  • Philippine Nuclear Research Institute, Commonwealth Ave., Diliman, Quezon City, 1101 Metro Manila, Philippines, Tel.: +632 929 6011, Fax: +632 920 1646
Bibliografia
  • 1. Brown, G. G. (1950). Unit operations. New York: Wiley.
  • 2. Jaafar, A. (2005). Gamma ray scanning for troubleshooting, optimization and predictive maintenance of distillation columns. Hydrocarbon Asia, Jan/Feb, 62–65.
  • 3. Charlton, J. S. (1985). Radioisotope techniques for problem-solving in industrial process plants. Glasgow: Leonard Hill.
  • 4. Kim, J., Jung, S., & Kim, J. (2007). The identification of flooding phenomenon in a column of refinery process by gamma absorption technique. J. Label. Compd. Radiopharm., 50(5/6), 605–606. doi:10.1002/jlcr.1299.
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-fcfd5322-caac-42c8-807c-9352eb63e605
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.