Agregaty osadu ściekowego uzyskane podczas elektrokoagulacji w systemie recyrkulacyjnym
Konferencja
ECOpole’16 Conference (5-8.10.2016 ; Zakopane, Poland)
Języki publikacji
Abstrakty
This paper presents the outcomes of tests of aggregates obtained from pulp and paper industry wastewater treatment using the electrocoagulation method. The test wastewater was treated on a laboratory scale with a recirculation system. Along with the wastewater treatment parameters, the fractal properties of the obtained aggregates were determined and their size was specified. The following wastewater parameters were tested: COD, turbidity and colour. For the conducted process, the fractal dimensions fell within the range of 1.30-1.70 at 0.1 A current. The applied current and electric charge flowing through the solution determined the efficiency of wastewater treatment, and impacted the structure, size and fractal dimensions of the obtained aggregates.
W pracy przedstawiono efekty badań agregatów uzyskanych w wyniku oczyszczania ścieków celulozowo-papierniczych metodą elektrokoagulacji. Modelowe ścieki oczyszczano w laboratoryjnej skali, używając systemu recyrkulacyjnego. Wraz z wyznaczeniem parametrów oczyszczania ścieków określano właściwości fraktalne otrzymanych agregatów i oznaczano ich rozmiar. Badano takie parametry ścieków, jak: ChZT, mętność, barwę. Dla tego procesu uzyskane rozmiary fraktalne mieściły się w przedziale 1,30-1,72 przy natężeniu prądu 0,1 A. Zastosowane natężenie prądu oraz ładunek elektryczny przepływający przez roztwór wyznaczały efektywność oczyszczania ścieków i wpływały na strukturę, wielkość i rozmiar fraktalny otrzymanych agregatów.
Czasopismo
Rocznik
Tom
Strony
363--368
Opis fizyczny
Bibliogr. 9 poz., rys., tab., wykr.
Twórcy
autor
- Department of Chemistry, Faculty of Environmental Management and Agriculture, University of Warmia and Mazury, pl. Łódzki 4, 10-957 Olsztyn, Poland
autor
- Department of Chemistry, Faculty of Environmental Management and Agriculture, University of Warmia and Mazury, pl. Łódzki 4, 10-957 Olsztyn, Poland
Bibliografia
- [1] Butler E, Hung Y-T, Yeh R, Al Ahmad M. Water. 2011;3:495-525. DOI: 10.3390/w3020495.
- [2] Heffron J, Marhefke M, Brooke K. Sci Rep. 2016;6:28478. DOI: 10.1038/srep28478.
- [3] Ghanbari F, Moradi M, Eslami A, Emamjomeh MM. Environ Process. 2014;1:447-457. DOI: 10.1007/s40710-014-0029-3.
- [4] Naje A, Chelliapan S, Zakaria Z, Ajeel MA, Alaba PA. Rev Chem Eng. 2016;33(3):263-292. DOI: 10.1515/revce-2016-0019.
- [5] Fouad YO. AEJ. 2014;53(1):199-204. DOI: 10.1016/j.aej.2013.10.005.
- [6] Shankar R, Singh L, Mondal P, Chand S. World J Environ Eng. 2013;1(2):16-20. DOI: 10.12691/wjee-1-2-1.
- [7] Smoczyński L, Muńska K, Pierożyński B, Kosobucka M. Proc ECOpole. 2012;6,401-408. DOI: 10.2429/proc.2012.6(1)056.
- [8] Amuda OS, Alade A. Desalination. 2006;196(1-3):22-31. DOI: 10.1016/j.desal.2005.10.039.
- [9] Załęska-Chróst B, Wardzyńska R. Water Sci Technol. 2016;1(73):161-166. DOI: 10.2166/wst.2015.476.
Uwagi
PL
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA