Anatomical structures are characterized by free surfaces, and most are in lobed and pseudo-spherical shapes. The aim of this article is to analyze selected procedures for accuracy assessment of the shape and dimensions of these structures using certified sphere and Ball Bar standards and to propose metrology parameters facilitating comparison of diagnostic devices. The spherical standard of various materials and Ball Bar standards with various distances between spheres centers can be a tool for evaluation of computed tomography metrology applications. Errors in geometry mapping can be identified on the basis of standardized control systems used in coordinate measuring techniques.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
231--236
Opis fizyczny
Bibliogr. 17 poz., rys., zdj.
Twórcy
autor
- Laboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Krakow, Poland
autor
- Laboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Krakow, Poland
autor
- Faculty of Medicine, Department of Prosthetic Dentistry, Jagiellonian University Medical College, Krakow, Poland
autor
- Laboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Krakow, Poland
autor
- Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Krakow, Poland
autor
- Laboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Krakow, Poland
Bibliografia
- 1. ASTM E1441 – 11 Standard Guide for Computed Tomography (CT) Imaging.
- 2. Chlebus E, Ziółkowski G, Dybała B. Industrial tomography application in the assembly analysis. Mechanic 2013;86:422–4.
- 3. Ratajczyk E. Industrial application of computer tomography (CT). Part IV. Software, accuracy parameters and their determination methods. Mechanic 2011;84:474–9.
- 4. Kowaluk T, Ratajczyk E. The accuracy of industrial computer tomography scanners in determining geometric dimensions. Meas Automat Monit 2013;59:462–5.
- 5. VDI/VDE 2630. Blatt 1.3., Computertomografie in der dimensionellen Messtechnik, Düsseldorf 2009.
- 6. Draft standard ISO 10360.
- 7. Kirschner J, Shah K, Runde D, Newman D, Godbout B, Wiener D, et al. Patterns in computed tomography utilization among emergency physicians in an urban, academic emergency department. Emerg Radiol 2014;21:577–81.
- 8. Ryniewicz A. Accuracy assessment of shape mapping using computer tomography. Metrol Meas Syst 2010;17:481–91.
- 9. Ratajczyk E. Computed tomography in 3D geometrical measurements. Meas Automat Monit 2011;57:220–3.
- 10. Kowaluk T, Woźniak A. Study of porosity measurement using the computer tomography. Meas Automat Robot 2012;16:82–6.
- 11. Yagüe-Fabra JA, Ontiveros S, Jiménez R, Chitchian S, Tosello G, Carmignato S. A 3D edge detection technique for surface extraction in computed tomography for dimensional metrology applications. CIRP Annals-Manuf Technol 2013;62:531–4.
- 12. Dewulf W, Kiekens K, Tan Y, Welkenhuyzen F, Kruth JP. Uncertainty determination and quantification for dimensional measurements with industrial computed tomography. CIRP Annals-Manuf Technol 2013;62:535–8.
- 13. Shammaa MH, Ohtake Y, Suzuki H. Segmentation of multimaterial CT data of mechanical parts for extracting boundary surfaces. Comput Aided Des 2010;42:118–28.
- 14. Dewulf W, Tan Y, Kiekens K. Sense and non-sense of beam hardening correction in CT metrology. CIRP Annals-Manuf Technol 2012;61:495–8.
- 15. Kruth JP, Bartscher M, Carmignato S, Schmitt R, De Chiffre L, Weckenmann A. Computed tomography for dimensional metrology. CIRP Annals-Manuf Technol 2011;60:821–42.
- 16. Ryniewicz A. Accuracy assessment of biobearings elements shape mapping in in vivo and in vitro analysis. Scientific Papers Warsaw University of Technology. Mechanics 2013;248:3–169.
- 17. Minister of Health Regulation of 24 December 2002 on the conditions of use of ionizing radiation for medical purposes, and how to perform internal control over the observance of these conditions. Dz.U. 2002 no. 241 poz. 2098.