PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Model of the Arm Manipulator in the Process of Spastic Limb Rehabilitation

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The article presents a model of the arm manipulator of spastic upper limb rehabilitation. It was based on a task dynamics analysis. As a result of the disease, upper limb does not function properly and does not perform the desired movement. It is a result of small damage of brain which is based on neurological substrate. In order to return the patient to movement ability, the rehabilitation involves on reconstruction of lost movement patterns, through prolonged repetition of limb movement exercises. In traditional way, this type of exercise, carried out by a physiotherapist. Nowadays it is done with the help of modern mechatronic solutions. Data and the proposed mathematical model presented in the article will allow for the development of guidelines for the future manipulator for upper limb rehabilitation. This information allowed us to develop a solution to eliminate spastic forces in muscles on arm, forearm and hand. They can also be a contribution not fully audited and described in the literature characteristic of the upper limb muscle contracture - spasticity
Rocznik
Strony
99--106
Opis fizyczny
Bibliogr. 11 poz., il., wykr.
Twórcy
autor
  • Rzeszów University of Technology. Department of Applied Mechanics and Robotics
Bibliografia
  • 1. Baran B. 2004, Measurement of the moments of spastic muscle (original title in Polish: Pomiar momentów sił mięśnia spastycznego). Konferencja Naukowa Studentów, Wrocław.
  • 2. Gedliczka A., Pochopień P., Szklarska A., Welon Z. 2001, Atlas of human measure. Data for the ergonomic design and evaluation (original title in Polish: Atlas miar człowieka. Dane do projektowania i oceny ergonomicznej), Centralny Instytut Ochrony Pracy, Warsaw.
  • 3. Giergiel, J., Giergiel, M., 2012, Mechanics (original title in Polish: Mechanika ogólna), Oficyna Wydawnicza Politechniki Rzeszowskiej, Rzeszow.
  • 4. Hendzel Z., Żylski W. 2005, Mechanics (original title in Polish:Mechanika ogólna), Oficyna Wydawnicza Politechniki Rzeszowskiej, Rzeszów.
  • 5. Hendzel Z., Gierlak P.: 2011, Control of wheeled robots and manipulators (original title in Polish: Sterowanie robotów kołowych i manipulatorów), Oficyna Wydawnicza Politechniki Rzeszowskiej, Rzeszów.
  • 6. Kumar R., Pandyan A.D., Sharma A.K. 2006, Biomechanical measurement of post – stroke spasticity. Age and Ageing (Oxford Journal Medicine).
  • 7. Stevens A., Lowe J. 2004, Pathology (original title in Polish: Patologia), Wyd. Czelej, Lublin.
  • 8. Toth A., Fazekas G., Arz G., Jurak M., Horvarth M. 2005, Passive robotnic movement therapy of the spastic hemiparetic arm with reharob: report of first clinical test and the follow – up system improvement. In 9th International Conference on Rehabilitation Robotics.
  • 9. Tutak J. 2012, Manipulator for Upper limb rehabilitation, (original title in Polish: Manianipulator do rehabilitacji kończyny górnej), PhD Thesis.
  • 10. Winkler T. 2005, Computer aided design systems anthropotechnical (original title in Polish: Komputerowo wspomagane projektowanie systemów antropotechnicznych), Wydaw. Naukowo – Techniczne, Warsaw.
  • 11. Wolański N., Niemiec S., Pyżuk M. 1975, Engineering anthropometry (original title in Polish: Antropometria inżynieryjna), Wydaw. Książka i Wiedza, Warsaw.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-fa0e46d8-99f2-459a-b276-9e4b3edc6898
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.