Stand tests of a powered roof support after a long time of operation : case study

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The process and results of stand tests on the powered support manufactured in 1996 are discussed. The tests were conducted at the KOMAG’s accredited testing laboratory, implementing an author’s testing program. After completion of the static strength, load bearing capacity and fatigue strength tests, the roof support was inspected and no mechanical damage to the basic components of the tested roof support was found. The recorded permanent deformations of the basic components of the roof support tested in 2020 were compared with the results of tests of the same roof support, conducted in 1996 (prototype tests) and 2009 (tests after modernisation), also at the KOMAG laboratory. Based on the results of tests conducted in 2020, it was shown that the current properties of the roof support meet the normative requirements. Therefore, the customer may decide to continue using them in other longwall panels.
PL
Omówiono przebieg i wyniki badań stanowiskowych sekcji obudowy zmechanizowanej wyprodukowanej 1996r. Badania wykonano w akredytowanym laboratorium badawczym ITG KOMAG, realizując autorski program badawczy. Po zakończeniu badań wytrzymałości statycznej, podporności i wytrzymałości zmęczeniowej, przeprowadzono oględziny sekcji i nie stwierdzono uszkodzeń mechanicznych elementów podstawowych badanej sekcji. Zarejestrowane odkształcenia trwałe elementów podstawowych sekcji badanej w 2020 r. porównano z wynikami badań tej samej sekcji, wykonanych w 1996 r. (badania prototypu) oraz 2009 r. (badanie po modernizacji), również w laboratorium ITG KOMAG. Na podstawie wyników badań wykonanych w 2020 r. wykazano, że aktualne właściwości funkcjonalne sekcji spełniają wymagania normatywne. Zleceniodawca może więc podjąć decyzję o dalszym użytkowaniu w kolejnych ścianach.
Czasopismo
Rocznik
Tom
Strony
22--33
Opis fizyczny
Bibliogr. 16 poz., rys., tab., wykr.
Twórcy
  • KOMAG Institute of Mining Technology, Pszzcyńska 37, 44-101 Gliwice, Poland
  • KOMAG Institute of Mining Technology, Pszzcyńska 37, 44-101 Gliwice, Poland
  • KOMAG Institute of Mining Technology, Pszzcyńska 37, 44-101 Gliwice, Poland
  • LW Bogdanka S.A. , Bogdanka, 21-013 Puchaczów, Poland
Bibliografia
  • [1] Rozporządzenie Ministra Energii z dn. 23 listopada 2016 r. w sprawie szczegółowych wymagań dotyczących prowadzenia ruchu podziemnych zakładów górniczych, Dz. U. z 2017 r. poz. 1118 wraz ze zmianami.
  • [2] Cemal B., Ergin A.: Design of Supports in Mines, John Wiley& Sons, New York 1983
  • [3] Szweda S., Szyguła M., Mazurek K.: Czynniki wpływające na postać konstrukcyjną i parametry techniczne sekcji ścianowej obudowy zmechanizowanej. Część1. Czynniki naturalne, techniczne i konstrukcyjne, ITG KOMAG, Gliwice 2016, ISBN 978-83-65593-01-6.
  • [4] Szyguła M.: Rozwój konstrukcji sekcji obudowy zmechanizowanej w górnictwie węgla kamiennego w Polsce. Maszyny Górnicze 2013 nr 2 s. 30-38.
  • [5] Jingyi Cheng, Syd S. Peng:Study on the factors influencing the load capacity of shield, Advances in Coal Mine Ground Control, 2017, s.35-65.
  • [6] Trueman R., Lyman A., Cocker G.: Longwall roof control through a fundamental understanding of shield–strata interaction, International Journal of Rock Mechanics and Mining Sciences, Vol. 46, Issue 2, February 2009, Pages 371-380.
  • [7] Markowicz J.: Analysis of impact of welded joint damages and corrosion in powered roof support components on their operational safety. Archives Of Mining Sciences, Vol.55, nr 4, 2010, s. 799-826
  • [8] Sprawozdanie z badań – Etap I nr 34/DLB/2020 (unpublished).
  • [9] European Standard EN 1804-1:2001+A1:2010Machines for underground mines –Safety requirements for hydraulic powered roof supports –Part 1: Support units and general requirements.
  • [10] Raport nr 48/DLB-1/96 (unpublished).
  • [11] Sprawozdanie z badań nr 119/DLB-1/2009 (unpublished).
  • [12] Testing procedure PB-DLB/10 Badanie sekcji obudowy zmechanizowanej. ITG KOMAG. Wydanie I z 01.02.2019r. (unpublished).
  • [13] Wytyczne konstruowania obudów zmechanizowanych i ich badań niezbędnych dla dopuszczenia do prób eksploatacyjnych i powszechnego stosowania Wydawca: Ministerstwo Przemysłu i Handlu, 1993.
  • [14] Polish StandardPN-G-50041:2000Ochrona pracy w górnictwie –Obudowy ścianowe zmechanizowane –Wymagania bezpieczeństwa i ergonomii (Work protection in mining industry --Powered roof supports --Safety and ergonomics requirements).
  • [15] Wojtaszczyk M.: Badanie konstrukcji obudów zmechanizowanych po wejściu do Unii Europejskiej. Materiały na konferencje: 2. Szkoła Mechanizacji i Automatyzacji Górnictwa, Wisła, 28-30 kwietnia 2004.
  • [16] Wojtaszczyk M.: Badanie konstrukcji obudów zmechanizowanych w aspekcie wymagań Unii Europejskiej, Materiały na konferencję: Efektywność stosowania zmechanizowanych kompleksów ścianowych remontowane czy nowe?, Ustroń, 1-2 kwietnia 2004.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2020).