PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Automatic Test Bench for Selected Transmission Parameters of Power Line Conductors

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This paper presents automatic test bench used for measurement of selected high frequency parameters of a power copper line. The aim is fast estimation of line behavior in context of Power Line Communication (PLC). The hardware interface uses sinusoidal waveform generator, digital oscilloscope and a PC-class computer. The software interface created in LabVIEW environment performs signal processing and data presentation.
Rocznik
Strony
59--65
Opis fizyczny
Bibliogr. 17 poz., il., rys., tab., wykr.
Twórcy
  • Silesian University of Technology; Faculty of Automatic Control, Electronics and Computer Science; Gliwice, Poland
Bibliografia
  • [1] Dostert, K. In Powerline Communications; Prentice-Hall: New York USA, 2001.
  • [2] Papadopoulos, A., Argyropoulos, G.C., Sarantinos, B.D., Papagiannis, G.K., Analysis of Indoor PLC Networks: Laboratory Tests and Simulation Results, IEEE Power Tech, Lausanne, pp. 1935,1940, 1-5 July 2007.
  • [3] Papadopoulos, T.A., Papagiannis, G.K., Dokopoulos, P.S., Low-Voltage Distribution Line Performance Evaluation for PLC Signal Transmission, Power Delivery, IEEE Transactions on, vol. 23, no.4, pp.1903, 1910, Oct. 2008.
  • [4] Razazian, K., Yazdani, J., CENELEC and powerline communication specification in realization of smart grid technology, Innovative Smart Grid Technologies (ISGT Europe), 2011 2nd IEEE PES International Conference and Exhibition on, pp.1,7, 5-7 Dec. 2011.
  • [5] Buchner, P., Fender, M., Compensation of low frequency harmonics caused by parallel operating AC converters, Industrial Electronics, ISIE '96, Proceedings of the IEEE International Symposium on, vol. 2, pp. 618, 623, 17-20 Jun 1996.
  • [6] Bmiller, G., Evaluation and integrated diagnostic of high speed narrow band power-line chipset, Power Line Communications and Its Applications, 2005 International Symposium on, pp. 371, 375, 6-8 April 2005.
  • [7] Malack, J.A., Engstrom, J.R., RF Impedance of United States and European Power Lines, IEEE Trans. Electromag. Compat. 1976, 18, 36-38.
  • [8] Guangbin Chu, Jianqi Li, Weilin Liu, Narrow band power line channel characteristics for low voltage access network in China, Power Line Communications and Its Applications (ISPLC), 17th IEEE International Symposium on, pp. 297, 302, 24-27 March 2013.
  • [9] Gassara, H., Rouissi, F., Ghazel, A., Statistical Characterization of the Indoor Low-Voltage Narrowband Power Line Communication Channel, Electromagnetic Compatibility, IEEE Transactions on, vol. 56, no.1, pp.123, 131, Feb. 2014.
  • [10] Cooper, D. ; Jeans, T., “Narrow-Band, Low Data Rate Communications on the Low-Voltage Mains in the CENELEC Frequencies, Part 1: Noise.
Typ dokumentu